Physiological Parameter Monitoring from Optical Recordings With a Mobile Phone

被引:296
作者
Scully, Christopher G. [1 ]
Lee, Jinseok [1 ]
Meyer, Joseph [2 ]
Gorbach, Alexander M. [2 ]
Granquist-Fraser, Domhnull [1 ]
Mendelson, Yitzhak [1 ]
Chon, Ki H. [1 ]
机构
[1] Worcester Polytech Inst, Dept Biomed Engn, Worcester, MA 01607 USA
[2] Natl Inst Biomed Imaging & Bioengn, NIH, Bethesda, MD 20892 USA
关键词
Breathing rate; heart rate variability (HRV); noninvasive monitoring; oxygen saturation; telemonitoring;
D O I
10.1109/TBME.2011.2163157
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We show that a mobile phone can serve as an accurate monitor for several physiological variables, based on its ability to record and analyze the varying color signals of a fingertip placed in contact with its optical sensor. We confirm the accuracy of measurements of breathing rate, cardiac R-R intervals, and blood oxygen saturation, by comparisons to standard methods for making such measurements (respiration belts, ECGs, and pulse-oximeters, respectively). Measurement of respiratory rate uses a previously reported algorithm developed for use with a pulse-oximeter, based on amplitude and frequency modulation sequences within the light signal. We note that this technology can also be used with recently developed algorithms for detection of atrial fibrillation or blood loss.
引用
收藏
页码:303 / 306
页数:4
相关论文
共 18 条
[1]  
[Anonymous], 2011, INST HEART RAT
[2]   How smartphones are changing the face of mobile and participatory healthcare: an overview, with example from eCAALYX [J].
Boulos, Maged N. Kamel ;
Wheeler, Steve ;
Tavares, Carlos ;
Jones, Ray .
BIOMEDICAL ENGINEERING ONLINE, 2011, 10
[3]   Estimation of Respiratory Rate From Photoplethysmogram Data Using Time-Frequency Spectral Estimation [J].
Chon, Ki H. ;
Dash, Shishir ;
Ju, Kihwan .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2009, 56 (08) :2054-2063
[4]   Automatic Real Time Detection of Atrial Fibrillation [J].
Dash, S. ;
Chon, K. H. ;
Lu, S. ;
Raeder, E. A. .
ANNALS OF BIOMEDICAL ENGINEERING, 2009, 37 (09) :1701-1709
[5]   Assessment of cardiovascular autonomic function [J].
Freeman, R .
CLINICAL NEUROPHYSIOLOGY, 2006, 117 (04) :716-730
[6]   Investigating a smartphone imaging unit for photoplethysmography [J].
Jonathan, E. ;
Leahy, Martin .
PHYSIOLOGICAL MEASUREMENT, 2010, 31 (11) :N79-N83
[7]   Cellular phone-based photoplethysmographic imaging [J].
Jonathan, Enock ;
Leahy, Martin J. .
JOURNAL OF BIOPHOTONICS, 2011, 4 (05) :293-296
[8]   An Overview of Recent Health Care Support Systems for eEmergency and mHealth Applications [J].
Kyriacou, E. C. ;
Pattichis, C. S. ;
Pattichis, M. S. .
2009 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-20, 2009, :1246-+
[9]   Can photoplethysmography variability serve as an alternative approach to obtain heart rate variability information? [J].
Lu S. ;
Zhao H. ;
Ju K. ;
Shin K. ;
Lee M. ;
Shelley K. ;
Chon K.H. .
Journal of Clinical Monitoring and Computing, 2008, 22 (01) :23-29
[10]  
Maeda Y., 2009, J MED SYST, P1