Utility of a Finger-Mounted Tissue Oximeter with Near-Infrared Spectroscopy to Evaluate Limb Ischemia in Patients with Peripheral Arterial Disease

被引:14
|
作者
Yata, Tatsuro [1 ,2 ]
Sano, Masaki [1 ,2 ]
Kayamal, Takafumi [1 ,2 ]
Naruse, Ena [1 ,2 ]
Yamamoto, Naoto [1 ,2 ,3 ]
Inuzuka, Kazunori [1 ,2 ]
Saito, Takaaki [1 ,2 ]
Katahashi, Kazuto [1 ,2 ]
Yamanaka, Yuta [1 ,2 ,3 ]
Uchida, Toshiyuki [4 ]
Niwayama, Masatsugu [5 ]
Kanayama, Naohiro [4 ]
Takeuchi, Hiroya [2 ]
Unno, Naoki [1 ,2 ,3 ]
机构
[1] Hamamatsu Univ Sch Med, Div Vasc Surg, Hamamatsu, Shizuoka, Japan
[2] Hamamatsu Univ, Sch Med, Dept Surg 2, Hamamatsu, Shizuoka, Japan
[3] Hamamatsu Med Ctr, Div Vasc Surg, Hamamatsu, Shizuoka, Japan
[4] Hamamatsu Univ Sch Med, Dept Obstet & Gynecol, Hamamatsu, Shizuoka, Japan
[5] Shizuoka Univ, Dept Elect & Elect Engn, Hamamatsu, Shizuoka, Japan
关键词
limb blood flow; near-infrared spectroscopy; peripheral arterial disease; regional hemoglobin oxygen saturation; TRANSCUTANEOUS OXYGEN-TENSION; INTERMITTENT CLAUDICATION; VASCULAR-DISEASE; RISK-FACTORS; PRESSURE; PREVALENCE; SATURATION; MANAGEMENT; PERFUSION; MUSCLE;
D O I
10.3400/avd.oa.18-00117
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Objective: To investigate whether a finger-mounted tissue oximeter is useful in evaluating limb blood flow in patients with peripheral arterial disease (PAD). Materials and Methods: Seventy-two patients with PAD were included, and the ankle-brachial index (ABI), transcutaneous oxygen pressure (TcPO2), and skin perfusion pressure (SPP) were measured. The regional tissue oxygenation saturation (rSO(2)) was measured using a finger-mounted tissue oximeter at the ankle, dorsal foot, and each dorsal and plantar toe. Correlations between rSO(2) and ABI and between TcPO2 and SPP were analyzed. The patients were divided into three groups: Fontaine IIa (F-IIa), IIb (F-IIb), and III and IV (F-III/IV) groups. The difference in rSO(2) between each group was analyzed. Results: Significant correlations were observed between rSO(2) and TcPO2 and between rSO(2) and SPP. TcPO2 and SPP in the F-III/IV group were significantly lower than those in the F-IIa group. rSO(2) in the F-IIb and F-III/IV groups was significantly lower than that in the F-IIa group. Conclusion: The measurement of rSO(2) using finger-mounted tissue oximetry is quick, simple, and painless. It can be used on any skin area and is useful to evaluate limb circulation in patients with PAD.
引用
收藏
页码:36 / 43
页数:8
相关论文
共 50 条
  • [1] Usefulness of a finger-mounted tissue oximeter with near-infrared spectroscopy for evaluating the intestinal oxygenation and viability in rats
    Suzuki, Yuhi
    Yamamoto, Masayoshi
    Sugiyama, Kosuke
    Akai, Toshiya
    Suzuki, Katsunori
    Kawamura, Takafumi
    Sakata, Mayu
    Morita, Yoshifumi
    Kikuchi, Hirotoshi
    Hiramatsu, Yoshihiro
    Kurachi, Kiyotaka
    Unno, Naoki
    Takeuchi, Hiroya
    SURGERY TODAY, 2021, 51 (06) : 931 - 940
  • [2] Usefulness of a finger-mounted tissue oximeter with near-infrared spectroscopy for evaluating the intestinal oxygenation and viability in rats
    Yuhi Suzuki
    Masayoshi Yamamoto
    Kosuke Sugiyama
    Toshiya Akai
    Katsunori Suzuki
    Takafumi Kawamura
    Mayu Sakata
    Yoshifumi Morita
    Hirotoshi Kikuchi
    Yoshihiro Hiramatsu
    Kiyotaka Kurachi
    Naoki Unno
    Hiroya Takeuchi
    Surgery Today, 2021, 51 : 931 - 940
  • [3] A Dynamic Objective Evaluation of Peripheral Arterial Disease by Near-Infrared Spectroscopy
    Manfredini, F.
    Malagoni, A. M.
    Felisatti, M.
    Mandini, S.
    Mascoli, F.
    Manfredini, R.
    Basaglia, N.
    Zamboni, P.
    EUROPEAN JOURNAL OF VASCULAR AND ENDOVASCULAR SURGERY, 2009, 38 (04) : 441 - 448
  • [4] Reliability of the Vascular Claudication Reporting in Diabetic Patients With Peripheral Arterial Disease: A Study With Near-Infrared Spectroscopy
    Manfredini, Fabio
    Lamberti, Nicola
    Malagoni, Anna Maria
    Zambon, Christel
    Basaglia, Nino
    Mascoli, Francesco
    Manfredini, Roberto
    Zamboni, Paolo
    ANGIOLOGY, 2015, 66 (04) : 365 - 374
  • [5] Near-infrared spectroscopy with a provocative maneuver to detect the presence of severe peripheral arterial disease
    Reiter, Homer-Christian J.
    Andersen, Charles A.
    JOURNAL OF VASCULAR SURGERY CASES INNOVATIONS AND TECHNIQUES, 2024, 10 (06):
  • [6] Examiner's finger-mounted near-infrared spectroscopy is feasible to analyze cerebral and skeletal muscle oxygenation in conscious Chihuahuas
    Hiwatashi, Keisuke
    Doi, Kimiaki
    Mizuno, Risuke
    Yokosuka, Makoto
    JOURNAL OF BIOMEDICAL OPTICS, 2017, 22 (02)
  • [7] Near-Infrared Spectroscopy Monitoring for Early Detection of Limb Ischemia in Patients on Veno-Arterial Extracorporeal Membrane Oxygenation
    Kim, Dong Jung
    Cho, Young-Jae
    Park, Sang Hon
    Lim, Cheong
    Park, Kay-Hyun
    Jheon, Sanghoon
    Kim, Jun Sung
    ASAIO JOURNAL, 2017, 63 (05) : 613 - 617
  • [8] Impact of Peripheral Angioplasty on Wound Oxygenation and Healing in Patients with Chronic Limb-Threatening Ischemia Measured by Near-Infrared Spectroscopy
    Schremmer, Johanna
    Stern, Manuel
    Baasen, Sven
    Wischmann, Patricia
    Foerster, Ramy
    Schillings, Miriam
    Bodis, Kalman
    Sansone, Roberto
    Heiss, Christian
    Kelm, Malte
    Busch, Lucas
    BIOMEDICINES, 2024, 12 (08)
  • [9] Quantitative near-infrared spectroscopy on patients with peripheral vascular disease
    Franceschini, MA
    Fantini, S
    Palumbo, R
    Pasqualini, L
    Vaudo, G
    Franceschini, E
    Gratton, E
    Palumbo, B
    Innocente, S
    Mannarino, E
    PHOTON PROPAGATION IN TISSUES III, PROCEEDINGS OF, 1998, 3194 : 112 - 115
  • [10] Near-infrared spectroscopy with treadmill exercise to assess lower limb ischemia in patients with atherosclerotic occlusive disease
    Watanabe, T
    Matsushita, M
    Nishikimi, N
    Sakurai, T
    Komori, K
    Nimura, Y
    SURGERY TODAY, 2004, 34 (10) : 849 - 854