Technical Considerations and Accuracy Improvement of Accelerometer-Based Portable Computer Navigation for Performing Distal Femoral Resection in Total Knee Arthroplasty

被引:17
|
作者
Fujimoto, Eisaku [1 ]
Sasashige, Yoshiaki [1 ]
Nakata, Kyouhei [1 ]
Yokota, Gen [1 ]
Omoto, Takenori [1 ]
Ochi, Mitsuo [2 ]
机构
[1] Chugoku Rousai Hosp, Dept Orthoped Surg, 1-5-1 Hirotagaya, Hiroshima 7370193, Japan
[2] Hiroshima Univ, Dept Orthopaed Surg, Hiroshima, Japan
关键词
knee; arthroplasty; accelerometer-based computer navigation; femoral component alignment; registration; alignment; TIBIAL RESECTION; JAPANESE PATIENTS; SYSTEM; ALIGNMENT; TKA;
D O I
10.1016/j.arth.2016.05.067
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Accelerometer-based computer navigation has been shown to be highly accurate for performing distal femoral and proximal tibial component alignment in total knee arthroplasty (TKA), although the procedure for the femoral component is less accurate than for the tibial component. Methods: First, 30 knees without hip osteoarthritis or proximal femoral surgeries were selected. Sequential hip adduction, abduction, and flexion were performed, and the femoral head was monitored fluoroscopically in the coronal plane before TKA. Significantly more movement was detected during hip adduction than during abduction and flexion. Then, postoperative femoral and tibial component alignment was retrospectively evaluated in 48 TKAs before fluoroscopic monitoring (early group) and in the next 61 TKAs with femoral registration using smaller adduction movements to avoid large femoral head movements (later group). Another 47 TKAs treated with the conventional intramedullary method for the distal femoral component and the extramedullary method for the proximal tibial component were also analyzed (IM and EM group) for historic control. Results: Significantly large variances in the femoral component implantation of the early group were detected in both the coronal and sagittal planes. The sagittal femoral implantation angle of the early group (4.6 +/- 3.0 degrees) was significantly larger than that of the later group (3.2 +/- 1.8 degrees) when 3.5 degrees was the target for both groups. No significant difference was detected in the variances of either the coronal or sagittal tibial component implantation, although the coronal tibial implantation angle was significantly smaller (-1.3 +/- 1.3 degrees valgus) in the early group than in the other groups. Conclusion: Accelerometer-based navigation sometimes has technical issues during registration associated with hip adduction. We showed that femoral registration without large adduction movements will enable more accurate femoral implantation. Surgeons should also keep in mind that the coronal tibial component is likely to be in valgus alignment (about 1 degrees) even if a neutral angle (0 degrees) is selected with this particular device. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:53 / 60
页数:8
相关论文
共 50 条
  • [41] Total Knee Arthroplasty in Patients With Extra-Articular Deformity: Restoration of Mechanical Alignment Using Accelerometer-Based Navigation System
    Matassi, Fabrizio
    Lepri, Andrea Cozzi
    Innocenti, Matteo
    Zanna, Luigi
    Civinini, Roberto
    Innocenti, Massimo
    JOURNAL OF ARTHROPLASTY, 2019, 34 (04) : 676 - 681
  • [42] Accuracy of a hand-held surgical navigation system for tibial resection in total knee arthroplasty
    Bugbee, William D.
    Kermanshahi, Arash Y.
    Munro, Michelle M.
    McCauley, Julie C.
    Copp, Steven N.
    KNEE, 2014, 21 (06) : 1225 - 1228
  • [43] Accelerometer-based portable navigation system shows no superior accuracy over pelvic alignment guide for acetabular cup placement in total hip arthroplasty in lateral decubitus position
    Okamoto, Masanori
    Takegami, Yasuhiko
    Osawa, Yusuke
    Tanaka, Shinya
    Nobori, Tatsuya
    Imagama, Shiro
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, : 4849 - 4856
  • [44] Influence of soft tissue balancing and distal femoral resection on flexion contracture in navigated total knee arthroplasty
    Kim, Seong Hwan
    Lim, Jung-Won
    Jung, Ho-Joong
    Lee, Han-Jun
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2017, 25 (11) : 3501 - 3507
  • [45] Total knee replacement with an accelerometer-based, hand-held navigation system improves knee alignment: reliable in all patients
    Perico, Diego Alarcon
    Perez, Sergio F. Guarin
    Lee, Sheng-Hsun
    Warne, Christopher N.
    Hadley, Matthew
    Taunton, Michael J.
    Sierra, Rafael J.
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (09) : 4125 - 4132
  • [46] Distal Femoral Valgus Resection Angle in Conventional Total Knee Arthroplasty-a CT Scanogram Study
    Basanagoudar, Praveen L.
    Satishkumar, Bhava R. J.
    Pattabiraman, Kirubakaran
    Kamath, Dinesh
    Ranganadham, A., V
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2023, 11 (03): : 181 - 188
  • [47] Accuracy of different navigation systems for femoral and tibial implantation in total knee arthroplasty: a randomised comparative study
    Saiki, Yoshitomo
    Ojima, Tomohiro
    Kabata, Tamon
    Hayashi, Seigaku
    Tsuchiya, Hiroyuki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2021, 141 (12) : 2267 - 2276
  • [48] Execution accuracy of bone resection and implant fixation in computer assisted minimally invasive total knee arthroplasty
    Kim, Tae Kyun
    Chang, Chong Bum
    Kang, Yeon Gwi
    Chung, Byung June
    Cho, Hyung Joon
    Seong, Sang Cheol
    KNEE, 2010, 17 (01) : 23 - 28
  • [49] Computer-assisted stereotaxic navigation improves the accuracy of mechanical alignment and component positioning in total knee arthroplasty
    Liow, Ming Han Lincoln
    Goh, Graham Seow-Hng
    Pang, Hee-Nee
    Tay, Darren Keng Jin
    Lo, Ngai Nung
    Yeo, Seng Jin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2016, 136 (08) : 1173 - 1180
  • [50] Accuracy of empirical distal femoral valgus cut angle of 4° to 6° in total knee arthroplasty: a randomized controlled trial
    Chaturong Pornrattanamaneewong
    Pakpoom Ruangsomboon
    Kittiwat Wingprawat
    Keerati Chareancholvanich
    Rapeepat Narkbunnam
    European Journal of Orthopaedic Surgery & Traumatology, 2022, 32 : 175 - 181