Technical Considerations and Accuracy Improvement of Accelerometer-Based Portable Computer Navigation for Performing Distal Femoral Resection in Total Knee Arthroplasty

被引:17
|
作者
Fujimoto, Eisaku [1 ]
Sasashige, Yoshiaki [1 ]
Nakata, Kyouhei [1 ]
Yokota, Gen [1 ]
Omoto, Takenori [1 ]
Ochi, Mitsuo [2 ]
机构
[1] Chugoku Rousai Hosp, Dept Orthoped Surg, 1-5-1 Hirotagaya, Hiroshima 7370193, Japan
[2] Hiroshima Univ, Dept Orthopaed Surg, Hiroshima, Japan
关键词
knee; arthroplasty; accelerometer-based computer navigation; femoral component alignment; registration; alignment; TIBIAL RESECTION; JAPANESE PATIENTS; SYSTEM; ALIGNMENT; TKA;
D O I
10.1016/j.arth.2016.05.067
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Accelerometer-based computer navigation has been shown to be highly accurate for performing distal femoral and proximal tibial component alignment in total knee arthroplasty (TKA), although the procedure for the femoral component is less accurate than for the tibial component. Methods: First, 30 knees without hip osteoarthritis or proximal femoral surgeries were selected. Sequential hip adduction, abduction, and flexion were performed, and the femoral head was monitored fluoroscopically in the coronal plane before TKA. Significantly more movement was detected during hip adduction than during abduction and flexion. Then, postoperative femoral and tibial component alignment was retrospectively evaluated in 48 TKAs before fluoroscopic monitoring (early group) and in the next 61 TKAs with femoral registration using smaller adduction movements to avoid large femoral head movements (later group). Another 47 TKAs treated with the conventional intramedullary method for the distal femoral component and the extramedullary method for the proximal tibial component were also analyzed (IM and EM group) for historic control. Results: Significantly large variances in the femoral component implantation of the early group were detected in both the coronal and sagittal planes. The sagittal femoral implantation angle of the early group (4.6 +/- 3.0 degrees) was significantly larger than that of the later group (3.2 +/- 1.8 degrees) when 3.5 degrees was the target for both groups. No significant difference was detected in the variances of either the coronal or sagittal tibial component implantation, although the coronal tibial implantation angle was significantly smaller (-1.3 +/- 1.3 degrees valgus) in the early group than in the other groups. Conclusion: Accelerometer-based navigation sometimes has technical issues during registration associated with hip adduction. We showed that femoral registration without large adduction movements will enable more accurate femoral implantation. Surgeons should also keep in mind that the coronal tibial component is likely to be in valgus alignment (about 1 degrees) even if a neutral angle (0 degrees) is selected with this particular device. (C) 2016 Elsevier Inc. All rights reserved.
引用
收藏
页码:53 / 60
页数:8
相关论文
共 50 条
  • [1] Accelerometer-Based Computer Navigation for Performing the Distal Femoral Resection in Total Knee Arthroplasty
    Nam, Denis
    Nawabi, Danyal H.
    Cross, Michael B.
    Heyse, Thomas J.
    Mayman, David J.
    JOURNAL OF ARTHROPLASTY, 2012, 27 (09) : 1717 - 1722
  • [2] Accuracy of A Handheld Accelerometer-Based Navigation System for Femoral and Tibial Resection in Total Knee Arthroplasty
    Huang, Eddie H.
    Copp, Steven N.
    Bugbee, William D.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (11) : 1906 - 1910
  • [3] Cadaveric analysis of an accelerometer-based portable navigation device for distal femoral cutting block alignment in total knee arthroplasty
    Nam, Denis
    Jerabek, Seth A.
    Cross, Michael B.
    Mayman, David J.
    COMPUTER AIDED SURGERY, 2012, 17 (04) : 205 - 210
  • [4] Usefulness of an accelerometer-based portable navigation system in total knee arthroplasty
    Ikawa, T.
    Takemura, S.
    Kim, M.
    Takaoka, K.
    Minoda, Y.
    Kadoya, Y.
    BONE & JOINT JOURNAL, 2017, 99B (08) : 1047 - 1052
  • [5] Comparison of a novel handheld accelerometer-based navigation system and conventional instrument for performing distal femoral resection in total knee arthroplasty: a randomized controlled trial
    Xu, Xingquan
    Liu, Peilai
    Yuan, Zhenfeng
    Wang, Dawei
    Lu, Qunshan
    Zhang, Zhe
    Jiang, Qing
    Shi, Dongquan
    ANNALS OF TRANSLATIONAL MEDICINE, 2019, 7 (22)
  • [6] Using Accelerometer-Based Portable Navigation to Perform Accurate Total Knee Arthroplasty Bone Resection in Asian Patients
    Ueyama, Hideki
    Matsui, Yoshio
    Minoda, Yukihide
    Matsuura, Masanori
    Nakamura, Hiroaki
    ORTHOPEDICS, 2017, 40 (03) : E465 - E472
  • [7] Accelerometer-Based, Portable Navigation vs Image less, Large-Console Computer-Assisted Navigation in Total Knee Arthroplasty A Comparison of Radiographic Results
    Nam, Denis
    Weeks, K. Durham
    Reinhardt, Keith R.
    Nawabi, Danyal H.
    Cross, Michael B.
    Mayman, David J.
    JOURNAL OF ARTHROPLASTY, 2013, 28 (02) : 255 - 261
  • [8] Efficacy of Portable Accelerometer-Based Navigation Devices versus Conventional Guides in Total Knee Arthroplasty: A Meta-analysis
    Sun, Han
    Li, Shuxiang
    Wang, Kun
    Wu, Guofeng
    Zhou, Jian
    Sun, Xiaoliang
    JOURNAL OF KNEE SURGERY, 2020, 33 (07) : 691 - 703
  • [9] Accuracy of tibial component placement in unicompartmental knee arthroplasty performed using an accelerometer-based portable navigation system
    Yoshio Matsui
    Shinichi Fukuoka
    Sho Masuda
    Masanori Matsuura
    Toshiaki Masada
    Kenji Fukunaga
    Knee Surgery, Sports Traumatology, Arthroscopy, 2020, 28 : 3733 - 3739
  • [10] Accuracy of tibial component placement in unicompartmental knee arthroplasty performed using an accelerometer-based portable navigation system
    Matsui, Yoshio
    Fukuoka, Shinichi
    Masuda, Sho
    Matsuura, Masanori
    Masada, Toshiaki
    Fukunaga, Kenji
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2020, 28 (12) : 3733 - 3739