Kinetic assay of D-Penicillamine in pure and pharmaceutical formulations based on ligand substitution reaction

被引:24
作者
Naik, Radhey M. [1 ]
Prasad, Surendra [2 ]
Kumar, Basant [1 ]
Chand, Vimlesh [2 ]
机构
[1] Univ Lucknow, Dept Chem, Lucknow 226007, Uttar Pradesh, India
[2] Univ S Pacific, Sch Biol & Chem Sci, Fac Sci Technol & Environm, Suva, Fiji
关键词
Ligand substitution reaction; Kinetic determination; D-Pencillamine; D-Pencillamine quantification; beta; beta-Dimethylcysteine determination; Kinetic spectrophotometric determination; HOMOGENEOUS ELECTROCATALYTIC OXIDATION; PERFORMANCE LIQUID-CHROMATOGRAPHY; PASTE ELECTRODE; VOLTAMMETRIC DETERMINATION; SPECTROPHOTOMETRIC METHOD; ELECTROCHEMICAL ANALYSIS; RHEUMATOID-ARTHRITIS; TRACE DETERMINATION; INDICATOR REACTION; DOSAGE FORMS;
D O I
10.1016/j.microc.2012.07.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A kinetic analytical method using uncatalyzed ligand substitution reaction and spectrophotometeric monitoring for the quantification of D-pencillamine (D-PA) i.e. 2-amino-3-mercapto-3-methylbutanoic acid or beta,beta-dimethylcysteine or 3-mercaptovaline or 3-mercapto-D-valine in pure as well as dosage forms has been validated and applied. The method is based on the uncatalyzed ligand substitution reaction between [Fe(CN)5(H2O)](3-) and D-PA which produces the complex [Fe(CN)5(D-PA)]3-. The substituted complex IFe(CN)5(D-PA)](3-) shows an absorption maximum at 421 nm. The proposed method shows good linear dynamic range of 14.92-149.21 pg mL(-1). By measuring the fixed time absorbance as a measure of initial rate of the complex formation during the course of the reaction at this wavelength, D-PA can be determined in the range 14.92-149.21 mu g mL(-1). The recoveries of D-PA from various samples spiked at the usage level have been quantitative. The limit of quantification (30-) was determined as 5.16, 3.68 and 3.13 mu g mL(-1) of D-PA corresponding to the fixed time of 2, 3 and 5 min respectively. The common excipients used as additives in pharmaceuticals did not interfere in the proposed method. The method was successfully employed for the analysis of D-PA content in commercial pharmaceutical preparations (tablets) and revealed quantities almost equal to those measured using the standard method, and demonstrated good accuracy and precision. The proposed method is rapid, simple, accurate and precise without the need for authentic analyte standards. It could therefore be used as an alternative to the quantification of D-PA in various samples. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:97 / 102
页数:6
相关论文
共 49 条