Experimental evaluation of stress distribution with narrow diameter implants: A finite element analysis

被引:32
作者
Cinel, Sezgi [1 ]
Celik, Ersan [2 ]
Sagirkaya, Elcin [2 ]
Sahin, Onur [3 ]
机构
[1] Gumushane Sehit Ebe Kevser Ceylan Publ Oral Hlth, Gumushane, Turkey
[2] Ordu Univ, Fac Dent, Dept Prosthodont, Ordu, Turkey
[3] Ordu Univ, Fac Dent, Dept Periodontol, Ordu, Turkey
关键词
TITANIUM-ZIRCONIUM; DENTAL IMPLANTS; SUPPORTED PROSTHESES; BONE QUALITY; ALLOY; CONFIGURATIONS; DENTURES; SYSTEM; REGION; TISSUE;
D O I
10.1016/j.prosdent.2017.04.024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Statement of problem. Narrow diameter implants were developed to allow placement in narrow alveolar ridges. Clinicians may have concerns about the durability and function of such implants. Purpose. The purpose of this finite element study was to compare the stress values occurring on the implant and at the implant bone interface after the application of the static and dynamic forces on narrow diameter, titanium and titanium-zirconia implants in the maxillary and mandibular second premolar region. Material and methods. Titanium (Ti) and titanium-zirconium (Ti-Zr) narrow diameter implants (3.3 mm in diameter, 10 mm in length) were simulated in the maxillary and mandibular second premolar region, and metal-ceramic crown restorations were designed. Forces of 100 N were applied to crowns in a vertical and oblique (45-degree angle to the long axis) direction. Maximum and minimum principal stresses in the cortical and trabecular bone and the von Mises stresses and fatigue strength of the implants were evaluated with 3-dimensional finite element analysis. Results. In vertical and oblique static loading, Ti and Ti-Zr implants showed similar stress distribution within the same jaw models. However, the von Mises stresses in Ti-Zr implants were slightly higher than for Ti implants in all models. In oblique static and dynamic loading, all stresses were found higher than vertical loading, and fatigue failure results were found to be more critical than vertical forces. Conclusions. Based on a numerical simulation, Ti and Ti-Zr alloys can be used successfully as narrow diameter implants in the second premolar area.
引用
收藏
页码:417 / 425
页数:9
相关论文
共 45 条
[1]   Numerical assessment of bone remodeling around conventionally and early loaded titanium and titanium-zirconium alloy dental implants [J].
Akca, Kivanc ;
Eser, Atilim ;
Cavusoglu, Yeliz ;
Sagirkaya, Elcin ;
Cehreli, Murat Cavit .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2015, 53 (05) :453-462
[2]   A Double-Blind Randomized Controlled Trial (RCT) of Titanium-13Zirconium versus Titanium Grade IV Small-Diameter Bone Level Implants in Edentulous Mandibles - Results from a 1-Year Observation Period [J].
Al-Nawas, Bilal ;
Bragger, Urs ;
Meijer, Henny J. A. ;
Naert, Ignace ;
Persson, Rigmor ;
Perucchi, Alessandro ;
Quirynen, Marc ;
Raghoebar, Gerry M. ;
Reichert, Torsten E. ;
Romeo, Eugenio ;
Santing, Hendrik J. ;
Schimmel, Martin ;
Storelli, Stefano ;
ten Bruggenkate, Christiaan ;
Vandekerckhove, Betty ;
Wagner, Wilfried ;
Wismeijer, Daniel ;
Mueller, Frauke .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2012, 14 (06) :896-904
[3]   The impact of loads on standard diameter, small diameter and mini implants: a comparative laboratory study [J].
Allum, Simon Rupert ;
Tomlinson, Rachel Anne ;
Joshi, Rajendra .
CLINICAL ORAL IMPLANTS RESEARCH, 2008, 19 (06) :553-559
[4]  
Bader Q., 2014, Int J Eng Technol, V14, P50
[5]   THE INFLUENCE OF IMPLANT DIAMETER AND LENGTH ON STRESS DISTRIBUTION OF OSSEOINTEGRATED IMPLANTS RELATED TO CRESTAL BONE GEOMETRY: A THREE-DIMENSIONAL FINITE ELEMENT ANALYSIS [J].
Baggi, Luigi ;
Cappelloni, Ilaria ;
Di Girolamo, Michele ;
Maceri, Franco ;
Vairo, Giuseppe .
JOURNAL OF PROSTHETIC DENTISTRY, 2008, 100 (06) :422-431
[6]  
Bernhard N., 2009, FORUM IMPLANTOL, V5, P30
[7]  
Bordin D, 2016, J PROSTHODONT, V18, P1
[8]   The future of complete dentures in oral rehabilitation. A critical review [J].
Carlsson, G. E. ;
Omar, R. .
JOURNAL OF ORAL REHABILITATION, 2010, 37 (02) :143-156
[9]   Titanium-zirconium alloy narrow-diameter implants (Straumann Roxolid®) for the rehabilitation of horizontally deficient edentulous ridges: prospective study on 18 consecutive patients [J].
Chiapasco, M. ;
Casentini, P. ;
Zaniboni, M. ;
Corsi, E. ;
Anello, T. .
CLINICAL ORAL IMPLANTS RESEARCH, 2012, 23 (10) :1136-1141
[10]   COMBINED EFFECTS OF IMPLANT INSERTION DEPTH AND ALVEOLAR BONE QUALITY ON PERIIMPLANT BONE STRAIN INDUCED BY A WIDE-DIAMETER, SHORT IMPLANT AND A NARROW-DIAMETER, LONG IMPLANT [J].
Chou, Hsuan-Yu ;
Muftu, Sinan ;
Bozkaya, Dincer .
JOURNAL OF PROSTHETIC DENTISTRY, 2010, 104 (05) :293-300