Simplified model for packed-bed tower regenerator in a liquid desiccant system

被引:51
作者
Kim, Min-Hwi [1 ]
Park, Joon-Young [1 ]
Jeong, Jae-Weon [1 ]
机构
[1] Hanyang Univ, Div Architectural Engn, Seoul 133791, South Korea
基金
新加坡国家研究基金会;
关键词
Packed-bed tower regenerator; Liquid desiccant system; Statistical analysis; Regeneration rate; MASS-TRANSFER; AIR DEHUMIDIFICATION; PERFORMANCE; HEAT;
D O I
10.1016/j.applthermaleng.2015.06.057
中图分类号
O414.1 [热力学];
学科分类号
摘要
The regeneration rate prediction model representing the regenerator performance in a liquid desiccant system was derived by statistically analyzing the empirical data collected from the real liquid desiccant unit operated under various conditions. In order to propose a simple empirical regenerator model with wide valid range, additional experimental data found in open literature were also considered in the model derivation. The lithium chloride (LiCl) solution was used as a working desiccant solution. Response surface methodology was used to identify operating parameters and their interactions affecting significantly on the regenerator performance in a liquid desiccant system. Consequently, a first-order linear regression equation was derived as a function of the major parameters and interactions, which returns the regeneration rate in various operating conditions. The reliability of the proposed model was confirmed via the analysis of variation (ANOVA). The proposed model agreed well with the experimental data and other existing models. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:717 / 726
页数:10
相关论文
共 50 条
  • [1] Simplified Heat and Mass Transfer Model for Cross-Flow and Countercurrent Flow Packed Bed Tower Dehumidifiers with a Liquid Desiccant System
    Hu, Shih-Cheng
    Shiue, Angus
    Chiu, Yi-Shiung
    Wang, Archy
    Chen, Jacky
    SUSTAINABILITY, 2016, 8 (12):
  • [2] Effect of regeneration mode on the performance of liquid desiccant packed bed regenerator
    Liu, X. H.
    Jiang, Y.
    Yi, X. Q.
    RENEWABLE ENERGY, 2009, 34 (01) : 209 - 216
  • [3] Performance study on the dehumidifier of a packed bed liquid desiccant system
    Salarian, H.
    Ghorbani, B.
    Amidpour, Majid
    Salehi, G.
    SCIENTIA IRANICA, 2014, 21 (01) : 222 - 228
  • [4] Macroscopic parameters investigation and transfer characteristics assessment of counter flow packed tower liquid desiccant dehumidifier/regenerator
    Deshmukh, Nandkishor S.
    Gawali, Bajirao S.
    Naik, B. Kiran
    Choudhari, Mahmadrafik S.
    Dhalait, Rustum S.
    HEAT AND MASS TRANSFER, 2023, 59 (07) : 1185 - 1207
  • [5] Handling zone dividing method in packed bed liquid desiccant dehumidification/regeneration process
    Liu, X. H.
    Jiang, Y.
    ENERGY CONVERSION AND MANAGEMENT, 2009, 50 (12) : 3024 - 3034
  • [6] Simplified Soft Sensing Model Applied in the Centralized Regenerator of a Distributed Operating Liquid Desiccant Dehumidification System
    Wu, Qiong
    Cai, WenJian
    Wang, Xinli
    Shen, Suping
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2016, 55 (34) : 9256 - 9266
  • [7] Study on the performance of celdek packed counter flow liquid desiccant regenerator
    Kumar, Rakesh
    Asati, Arun Kumar
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2017, 31 (09) : 4489 - 4498
  • [8] Mechanistic Grey-Box Modeling of a Packed-Bed Regenerator for Industrial Applications
    Halmschlager, Verena
    Muellner, Stefan
    Hofmann, Rene
    ENERGIES, 2021, 14 (11)
  • [9] Experimental Study on Effectiveness of Celdek Packed Liquid Desiccant Cooling System
    Kumar, Rakesh
    Asati, Arun Kumar
    HEAT TRANSFER ENGINEERING, 2018, 39 (10) : 914 - 922
  • [10] Performance investigation on the liquid desiccant regeneration using rotating packed bed
    Gu, Yangyang
    Zhang, Xiaosong
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 109 (109) : 45 - 54