Modelling the spine as a deformable body: Feasibility of reconstruction using an optoelectronic system

被引:34
作者
Ranavolo, Alberto [1 ]
Don, Romildo [2 ]
Draicchio, Francesco [1 ]
Bartolo, Michelangelo [3 ]
Serrao, Mariano [4 ]
Padua, Luca [5 ,6 ]
Cipolla, Gianfranco [7 ]
Pierelli, Francesco [8 ]
Iavicoli, Sergio [1 ]
Sandrini, Giorgio [9 ]
机构
[1] INAIL, Dept Occupat Med, I-00040 Monte Porzio Catone, Rome, Italy
[2] Ist Auxol Italiano, Verbania Milano, Italy
[3] IRCCS Ist Neurol Mediterraneo NEUROMED, UOC Neuroriabilitaz, Pozzilli, IS, Italy
[4] Univ Roma La Sapienza, Dept Med & Surg Sci & Biotechnol, Rome, Italy
[5] Don Carlo Gnocchi Onlus Fdn, Milan, Italy
[6] Univ Cattolica Sacro Cuore, Dept Neurosci, Inst Neurol, Rome, Italy
[7] Osped S Biagio, Dipartimento Diagnost Immagini & Radioterapia, Domodossola, VB, Italy
[8] IRCCS NEUROMED, Pozzilli, IS, Italy
[9] Univ Pavia, IRCCS C Mondino Fdn, Dept Neurol & Neurorehabil, I-27100 Pavia, Italy
关键词
Spine modelling tool; Manual material handling; Kinematics; LOW-BACK-PAIN; DESIGNING ERGONOMIC INTERVENTIONS; GAIT ANALYSIS DATA; MOVEMENT ANALYSIS; TRUNK KINEMATICS; THORACIC KYPHOSIS; LUMBAR SPINE; LOAD CARRIAGE; EMS WORKERS; MOTION;
D O I
10.1016/j.apergo.2012.07.004
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The aims of this study were to develop a kinematic model of the spine, seen as a continuous deformable body and to identify the smallest set of surface markers allowing adequate measurements of spine motion. The spine is widely considered as a rigid body or as a kinematic chain made up of a smaller number of segments, thereby introducing an approximation. It would be useful to have at our disposal a technique ensuring accurate and repeatable measurement of the shape of the whole spine. Ten healthy subjects underwent a whole-spine radiographic assessment and, simultaneously, an optoelectronic recording. Polynomial interpolations of the vertebral centroids, of the whole set of markers were performed. The similarity of the resulting curves was assessed. Our findings indicate that spine shape can be reproduced by 5th order polynomial interpolation. The best approximating curves are obtained from either 10- or 9-marker sets. Sagittal angles are systematically underestimated. (C) 2012 Elsevier Ltd and The Ergonomics Society. All rights reserved.
引用
收藏
页码:192 / 199
页数:8
相关论文
共 83 条
  • [21] Injury-induced kinematic compensations within the lower back: impact of non-lower back injuries
    Davis, KG
    Seol, H
    [J]. ERGONOMICS, 2005, 48 (02) : 135 - 149
  • [22] A GAIT ANALYSIS DATA-COLLECTION AND REDUCTION TECHNIQUE
    DAVIS, RB
    OUNPUU, S
    TYBURSKI, D
    GAGE, JR
    [J]. HUMAN MOVEMENT SCIENCE, 1991, 10 (05) : 575 - 587
  • [23] Human movement analysis using stereophotogrammetry - Part 4: assessment of anatomical landmark misplacement and its effects on joint kinematics
    Della Croce, U
    Leardini, A
    Chiari, L
    Cappozzo, A
    [J]. GAIT & POSTURE, 2005, 21 (02) : 226 - 237
  • [24] Intra- and inter-observer reliability of determining radiographic sagittal parameters of the spine and pelvis using a manual and a computer-assisted methods
    Dimar, John R., II
    Carreon, Leah Y.
    Labelle, Hubert
    Djurasovic, Mladen
    Weidenbaum, Mark
    Brown, Courtney
    Roussouly, Pierre
    [J]. EUROPEAN SPINE JOURNAL, 2008, 17 (10) : 1373 - 1379
  • [25] Effects of age and gender on maximum voluntary range of motion of the upper body joints
    Doriot, N
    Wang, XG
    [J]. ERGONOMICS, 2006, 49 (03) : 269 - 281
  • [26] The influence of individual low back health status on workplace trunk kinematics and risk of low back disorder
    Ferguson, SA
    Marras, WS
    Burr, DL
    [J]. ERGONOMICS, 2004, 47 (11) : 1226 - 1237
  • [27] The upper body segmental movements during walking by young females
    Frigo, C
    Carabalona, R
    Mura, MD
    Negrini, S
    [J]. CLINICAL BIOMECHANICS, 2003, 18 (05) : 419 - 425
  • [28] Effects of posture on dynamic back loading during a cable lifting task
    Gallagher, S
    Marras, WS
    Davis, KG
    Kovacs, K
    [J]. ERGONOMICS, 2002, 45 (05) : 380 - 398
  • [29] Effects of varying backpack loads on peak forces in the lumbosacral spine during walking
    Goh, JH
    Thambyah, A
    Bose, K
    [J]. CLINICAL BIOMECHANICS, 1998, 13 : S26 - S31
  • [30] A DATABASE FOR ESTIMATING NORMAL SPINAL MOTION DERIVED FROM NONINVASIVE MEASUREMENTS
    GRACOVETSKY, S
    NEWMAN, N
    PAWLOWSKY, M
    LANZO, V
    DAVEY, B
    ROBINSON, L
    [J]. SPINE, 1995, 20 (09) : 1036 - 1046