Late Pseudocoarctation Syndrome After Stent-Graft Implantation For Traumatic Aortic Rupture

被引:0
作者
Letocart, Vincent [1 ,2 ]
Fau, Georges [1 ]
Tirouvanziam, Ashok [1 ]
Toquet, Claire [3 ]
Al Habash, Oussama [1 ]
Guerin, Patrice [1 ]
Rousseau, Herve [4 ]
Crochet, Dominique [1 ]
机构
[1] Univ Hosp Nantes, Inst Thorax, Nantes, France
[2] CHU Nantes, CHR GR Laennec, Inst Thorax, Clin Cardiol, F-44093 Nantes 1, France
[3] Univ Hosp Nantes, Dept Pathol, Nantes, France
[4] Univ Hosp Toulouse, Dept Radiol, Toulouse, France
关键词
Stent-Graft; Pseudocoarctation; Neoendothelium; Aortic injury; ENDOVASCULAR REPAIR; ISTHMUS; DISEASE;
D O I
10.1007/s00270-012-0436-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The present observation illustrates an unusual complication occurring after stent-grafting (S-graft) for aortic isthmus rupture. A 22-year-old patient, treated by S-graft in the emergency department for traumatic aortic rupture, was readmitted 10 months later with pseudocoarctation syndrome. A membrane was found inside the stent-graft that had induced a pseudo-dissection, which caused the pseudocoarctation syndrome. Surgical treatment consisted of removing the stent-graft and membrane and replacing it with a vascular implant. The patient's clinical course was fair. The suggested mechanism was circumferential neoendothelialization of the stent-graft. Dehiscence caused the superior part of the membrane to drop into the lumen of the stent-graft creating a "false channel" that compressed the "true lumen" and induced "pseudocoarctation" syndrome. The cause of the extensive neointimalization remains unexplained. Thoracic aortic stent-grafts require regular follow-up monitoring by angioscan or angio-magnetic resonance imaging.
引用
收藏
页码:824 / 828
页数:5
相关论文
共 13 条
  • [1] Factors favoring stent-graft collapse after thoracic endovascular aortic repair
    Canaud, Ludovic
    Alric, Pierre
    Desgranges, Pascal
    Marzelle, Jean
    Marty-Ane, Charles
    Becquemin, Jean-Pierre
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2010, 139 (05) : 1153 - 1157
  • [2] Endovascular Aortic Repair Versus Open Surgical Repair for Descending Thoracic Aortic Disease A Systematic Review and Meta-Analysis of Comparative Studies
    Cheng, Davy
    Martin, Janet
    Shennib, Hani
    Dunning, Joel
    Muneretto, Claudio
    Schueler, Stephan
    Von Segesser, Ludwig
    Sergeant, Paul
    Turina, Marko
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2010, 55 (10) : 986 - 1001
  • [3] Prospective study of blunt aortic injury: Multicenter trial of the American Association for the Surgery of Trauma
    Fabian, TC
    Richardson, JD
    Croce, MA
    Smith, JS
    Rodman, G
    Kearney, PA
    Flynn, W
    Ney, AL
    Cone, JB
    Luchette, FA
    Wisner, DH
    Scholten, DJ
    Beaver, BL
    Conn, AK
    Coscia, R
    Hoyt, DB
    Morris, JA
    Harviel, JD
    Peitzman, AB
    Bynoe, RP
    Diamond, DL
    Wall, M
    Gates, JD
    Asensio, JA
    McCarthy, MC
    Girotti, MJ
    VanWijngaarden, M
    Cogbill, TH
    Levison, MA
    Aprahamian, C
    Sutton, JE
    Allen, CF
    Hirsch, EF
    Nagy, K
    Bachulis, BL
    Bales, CR
    Shapiro, MJ
    Metzler, MH
    Conti, VR
    Baker, CC
    Bannon, MP
    Ochsner, MG
    Thomason, MH
    Hiatt, JR
    OMalley, K
    Obeid, FN
    Gray, P
    Bankey, PE
    Knudson, MM
    Dyess, DL
    [J]. JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1997, 42 (03): : 374 - 380
  • [4] Physiologic coarctation of the aorta resulting from proximal protrusion of thoracic aortic stent grafts into the arch
    Go, Michael R.
    Siegenthaler, Michael P.
    Rhee, Robert Y.
    Gupta, NavYash
    Makaroun, Michel S.
    Cho, Jae-Sung
    [J]. JOURNAL OF VASCULAR SURGERY, 2008, 48 (04) : 1007 - 1011
  • [5] Aortic endograft sizing in trauma patients with hemodynamic instability
    Jonker, Frederik H. W.
    Verhagen, Hence J. M.
    Mojibian, Hamid
    Davis, Kimberly A.
    Moll, Frans L.
    Muhs, Bart E.
    [J]. JOURNAL OF VASCULAR SURGERY, 2010, 52 (01) : 39 - 44
  • [6] Endovascular treatment of traumatic rupture of the thoracic aorta
    Lettinga-van de Poll, T.
    Schurink, G. W. H.
    De Haan, M. W.
    Verbruggen, J. P. A. M.
    Jacobs, M. J.
    [J]. BRITISH JOURNAL OF SURGERY, 2007, 94 (05) : 525 - 533
  • [7] Endovascular repair of traumatic rupture of the aortic isthmus:: Midterm results
    Marcheix, Bertrand
    Dambrin, Camille
    Bolduc, Jean-Philippe
    Arnaud, Catherine
    Hollington, Lucy
    Cron, Christophe
    Mugniot, Antoine
    Soula, Philippe
    Bennaceur, Mehdi
    Chabbert, Valerie
    Otal, Philippe
    Cerene, Alain
    Rousseau, Herve
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 132 (05) : 1037 - 1041
  • [8] TRAUMATIC RUPTURE OF THE AORTIC ISTHMUS - AN EMERGENCY
    PATE, JW
    FABIAN, TC
    WALKER, W
    [J]. WORLD JOURNAL OF SURGERY, 1995, 19 (01) : 119 - 126
  • [9] Riesenman Paul J, 2007, Vasc Endovascular Surg, V41, P533, DOI 10.1177/1538574407305020
  • [10] Rousseau H, 2009, SYNDROMES AORTIQUES, P205