BONE APPOSITION TO A TITANIUM-ZIRCONIUM ALLOY IMPLANT, AS COMPARED TO TWO OTHER TITANIUM-CONTAINING IMPLANTS

被引:94
|
作者
Saulacic, N. [1 ,2 ]
Bosshardt, D. D. [3 ]
Bornstein, M. M. [1 ]
Berner, S. [4 ]
Buser, D. [1 ]
机构
[1] Univ Bern, Sch Dent Med, Dept Oral Surg & Stomatol, CH-3010 Bern, Switzerland
[2] Univ Hosp Bern, Dept Craniomaxillofacial Surg, CH-3010 Bern, Switzerland
[3] Univ Bern, Sch Dent Med, Robert K Schenk Lab Oral Histol, CH-3010 Bern, Switzerland
[4] Inst Straumann AG, Basel, Switzerland
关键词
Osseointegration; dental implant; titanium-zirconium alloy; histology; histomorphometry; COMMERCIALLY PURE TITANIUM; MEMORY METAL ALLOY; MINIATURE PIGS; SURFACE CHARACTERISTICS; MECHANICAL-PROPERTIES; TISSUE INTEGRATION; DENTAL IMPLANTS; OSSEOINTEGRATION; TI; TI6AL4V;
D O I
10.22203/eCM.v023a21
中图分类号
Q813 [细胞工程];
学科分类号
摘要
Implants made of commercially pure titanium (cpTi) are widely and successfully used in dentistry. For certain indications, diameter-reduced Ti alloy implants with improved mechanical strength are highly desirable. The aim was to compare the osseointegration of titanium-zirconium (TiZr) and cpTi implants with a modified sandblasted and acid-etched (SLActive) surface and with a Ti6Al4V alloy that was sand-blasted and acid-washed. Cylindrical implants with two, 0.75 mm deep, circumferential grooves were placed in the maxilla of miniature pigs and allowed to heal for 1, 2, 4 and 8 weeks. Undecalcified toluidine blue-stained ground sections were produced. Surface topography, area fraction of tissue components, and bone-to-implant contact (BIC) were determined. All materials showed significantly different surface roughness parameters. The amount of new bone within the implant grooves increased over time, without significant differences between materials. However, BIC values were significantly related to the implant material and the healing period. For TiZr and cpTi implants, the BIC increased over time, reaching values of 59.38 % and 76.15 % after 2 weeks, and 74.50 % and 84.67 % after 8 weeks, respectively. In contrast, the BIC for Ti6Al4V implants peaked with 42.29 % after 2 weeks followed by a decline to 28.60 % at 8 weeks. Significantly more surface was covered by multinucleated giant cells on Ti6Al4V implants after 4 and 8 weeks. In conclusion, TiZr and cpTi implants showed faster osseointegration than Ti6Al4V implants. Both chemistry and surface topography might have influenced the results. The use of diameter-reduced TiZr implants in more challenging clinical situations warrants further documentation in long-term clinical studies.
引用
收藏
页码:273 / 288
页数:16
相关论文
共 50 条
  • [21] Fracture Resistance Behaviors of Titanium-Zirconium and Zirconia Implants
    Hanes, Brenda
    Feitosa, Sabrina
    Phasuk, Kamolphob
    Levon, John A.
    Morton, Dean
    Lin, Wei-Shao
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2022, 31 (05): : 441 - 446
  • [22] Rotational Load Fatigue Performance of Titanium vs Titanium-Zirconium Implant-Abutment Connections
    Leo, Song Jie
    Tan, Ming Yi
    Yee, Sophia Hui Xin
    Lee, Frank Kong Fei
    Tan, Keson Beng Choon
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2022, 37 (04) : 740 - 747
  • [23] Influence of implant location on titanium-zirconium alloy narrow-diameter implants: A 1-year prospective study in smoking and nonsmoking populations
    Xiao, Wenlan
    Chen, Yaqian
    Chu, Chenyu
    Dard, Michel M.
    Man, Yi
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (02) : 159 - 166
  • [24] An In Vitro Biomechanical Evaluation of a New Commercial Titanium-Zirconium Alloy Dental Implant: A Pilot Study
    Wu, Aaron Yu-Jen
    Hsu, Jui-Ting
    Huang, Heng-Li
    IMPLANT DENTISTRY, 2014, 23 (05) : 534 - 538
  • [25] A review in titanium-zirconium binary alloy for use in dental implants: Is there an ideal Ti-Zr composing ratio?
    Zhao, Qian
    Ueno, Takeshi
    Wakabayashi, Noriyuki
    JAPANESE DENTAL SCIENCE REVIEW, 2023, 59 : 28 - 37
  • [26] Implant survival and patient satisfaction of reduced diameter implants made from a titanium-zirconium alloy: A retrospective cohort study with 550 implants in 311 patients
    Herrmann, Jan
    Hentschel, Andreas
    Glauche, Ingmar
    Vollmer, Armin
    Schlegel, Karl Andreas
    Lutz, Rainer
    JOURNAL OF CRANIO-MAXILLOFACIAL SURGERY, 2016, 44 (12) : 1940 - 1944
  • [27] EFFECT OF SINTERING TIME AND TEMPERATURE ON THE MICROHARDNESS OF TITANIUM-ZIRCONIUM ALLOY
    Slokar Benic, Ljerka
    Komljenovic, Luka
    Erman, Ziga
    Jajcinovic, Magdalena
    31ST INTERNATIONAL CONFERENCE ON METALLURGY AND MATERIALS, METAL 2022, 2022, : 779 - 784
  • [28] Clinical evidence on titanium-zirconium dental implants: a systematic review and meta-analysis
    Altuna, P.
    Lucas-Taule, E.
    Gargallo-Aibiol, J.
    Figueras-Alvarez, O.
    Hernandez-Alfaro, F.
    Nart, J.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2016, 45 (07) : 842 - 850
  • [29] A Prospective Case-Control Clinical Study of Titanium-Zirconium Alloy Implants with a Hydrophilic Surface in Patients with Type 2 Diabetes Mellitus
    Cabrera-Dominguez, Jose J.
    Castellanos-Cosano, Lizett
    Torres-Lagares, Daniel
    Machuca-Portillo, Guillermo
    INTERNATIONAL JOURNAL OF ORAL & MAXILLOFACIAL IMPLANTS, 2017, 32 (05) : 1135 - 1144
  • [30] Macrophage behavior and interplay with gingival fibroblasts cultured on six commercially available titanium, zirconium, and titanium-zirconium dental implants
    Yulan Wang
    Yufeng Zhang
    Anton Sculean
    Dieter D Bosshardt
    Richard J Miron
    Clinical Oral Investigations, 2019, 23 : 3219 - 3227