Multi-residue analysis of pesticide residues and polychlorinated biphenyls in fruit and vegetables using orbital ion trap high-resolution accurate mass spectrometry

被引:11
作者
Garvey, Jim [1 ]
Walsh, Tony [1 ]
Devaney, Elaine [1 ]
King, Teresa [1 ]
Kilduff, Ross [1 ]
机构
[1] Dept Agr Food & Marine, Food Chem Labs, Celbridge W23 VW2C, Kildare, Ireland
关键词
Pesticide residues; Polychlorinated biphenyls; High-resolution accurate mass; GC Q-Orbitrap; Fruit and vegetables; LIQUID-CHROMATOGRAPHY; GAS-CHROMATOGRAPHY; EXTRACTION; MS/MS; VALIDATION;
D O I
10.1007/s00216-020-02844-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
With the increasing demand on pesticide residue laboratories to increase their scope of analysis, high-resolution accurate mass (HRAM) systems have found increasing popularity in this area. The systems have the advantage of much more reliable confirmation as high resolution increases the ability to distinguish between masses which are close together and the mass accuracy achieved limits the number of structural formulae. To date, much of the work involving these systems has revolved around developing screening methods and little has been done on use of these systems for quantitative methods. Here we describe the development and validation of a quantitative method for the analysis of 167 pesticide residues and polychlorinated biphenyls (PCBs) in samples of fruit and vegetables according to the protocol described in EU SANTE guidance document. The determination method involves analysis using a GC QExactive orbitrap in full scan mode using EI. The samples were then extracted using the standard mini-Luke method. After extraction with acetone/dichloromethane/petroleum ether 40-60 degrees C, a solvent exchange into ethyl acetate is carried out. Recovery work was carried out in cucumber, lemon and broccoli representing high water content, high acid content and high chlorophyll content commodity groups. The results show that the default MRL of 10 ppb can be achieved for more than 93% of the pesticides studied. Mass accuracy, ion ratio and matrix effect studies show that the method is robust and provides a viable alternative to triple quadrupole mass spectrometer systems for the quantification of pesticide residues in fruit and vegetable samples.
引用
收藏
页码:7113 / 7121
页数:9
相关论文
共 50 条
[31]   Application of high-performance liquid chromatography–tandem mass spectrometry with a quadrupole/linear ion trap instrument for the analysis of pesticide residues in olive oil [J].
M. D. Hernando ;
C. Ferrer ;
M. Ulaszewska ;
J. F. García-Reyes ;
A. Molina-Díaz ;
A. R. Fernández-Alba .
Analytical and Bioanalytical Chemistry, 2007, 389 :1815-1831
[32]   Comparative evaluation of multi-residue methods for analysis of pesticide residues in black pepper by gas chromatography tandem mass spectrometry: critical evaluation of matrix co-extractives and method validation [J].
Kandaswamy, Chandrasekar ;
Anandaram, Sreekanth ;
Presley, S. I. Davis ;
Shabeer, Ahammed T. P. .
JOURNAL OF FOOD SCIENCE AND TECHNOLOGY-MYSORE, 2021, 58 (03) :911-920
[33]   Optimization of multi-residue method for targeted screening and quantitation of 243 pesticide residues in cardamom (Elettaria cardamomum) by gas chromatography tandem mass spectrometry (GC-MS/MS) analysis [J].
Shabeer, T. P. Ahammed ;
Girame, Rushali ;
Utture, Sagar ;
Oulkar, Dasharath ;
Banerjee, Kaushik ;
Ajay, D. ;
Arimboor, Ranjith ;
Menon, K. R. K. .
CHEMOSPHERE, 2018, 193 :447-453
[34]   Multiclass and multi-residue screening of mycotoxins, pharmacologically active substances, and pesticides in infant milk formulas through ultra-high-performance liquid chromatography coupled with high-resolution mass spectrometry analysis [J].
Izzo, Luana ;
Narvaez, Alfonso ;
Castaldo, Luigi ;
Gaspari, Anna ;
Rodriguez-Carrasco, Yelko ;
Grosso, Michela ;
Ritieni, Alberto .
JOURNAL OF DAIRY SCIENCE, 2022, 105 (04) :2948-2962
[35]   Accurate Mass Fragment Library for Rapid Analysis of Pesticides on Produce Using Ambient Pressure Desorption Ionization with High-Resolution Mass Spectrometry [J].
Kern, Sara E. ;
Lin, Lora A. ;
Fricke, Frederick L. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (08) :1482-1488
[36]   Analysis of emerging contaminants in water and solid samples using high resolution mass spectrometry with a Q Exactive orbital ion trap and estrogenic activity with YES-assay [J].
Comtois-Marotte, Simon ;
Chappuis, Thomas ;
Sung Vo Duy ;
Gilbert, Nicolas ;
Lajeunesse, Andre ;
Taktek, Salma ;
Desrosiers, Melanie ;
Veilleux, Eloise ;
Sauve, Sebastien .
CHEMOSPHERE, 2017, 166 :400-411
[37]   Multiclass pesticide residue analysis in tobacco (Nicotiana tabacum) using high performance liquid chromatography-high resolution (Orbitrap) mass spectrometry: A simultaneous screening and quantitative method [J].
Paul, Anindita ;
Khan, Zareen ;
Bhattacharyya, Arijita ;
Majumder, Sujan ;
Banerjee, Kaushik .
JOURNAL OF CHROMATOGRAPHY A, 2021, 1648
[38]   Application of high-performance liquid chromatography-tandem mass spectrometry with a quadrupole/linear ion trap instrument for the analysis of pesticide residues in olive oil [J].
Hernando, M. D. ;
Ferrer, C. ;
Ulaszewska, M. ;
Garcia-Reyes, J. F. ;
Molina-Diaz, A. ;
Fernandez-Alba, A. R. .
ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2007, 389 (06) :1815-1831
[39]   Glyphosate and other highly polar pesticides in fruit, vegetables and honey using ion chromatography coupled with high resolution mass spectrometry: Method validation and its applicability in an official laboratory [J].
Gasparini, Mara ;
Angelone, Barbara ;
Ferretti, Enrica .
JOURNAL OF MASS SPECTROMETRY, 2020, 55 (11)
[40]   Multi-residue method for trace level determination of pharmaceuticals in solid samples using pressurized liquid extraction followed by liquid chromatography/quadrupole-linear ion trap mass spectrometry [J].
Jelic, Aleksandra ;
Petrovic, Mira ;
Barcelo, Damia .
TALANTA, 2009, 80 (01) :363-371