Multi-residue analysis of pesticide residues and polychlorinated biphenyls in fruit and vegetables using orbital ion trap high-resolution accurate mass spectrometry

被引:11
|
作者
Garvey, Jim [1 ]
Walsh, Tony [1 ]
Devaney, Elaine [1 ]
King, Teresa [1 ]
Kilduff, Ross [1 ]
机构
[1] Dept Agr Food & Marine, Food Chem Labs, Celbridge W23 VW2C, Kildare, Ireland
关键词
Pesticide residues; Polychlorinated biphenyls; High-resolution accurate mass; GC Q-Orbitrap; Fruit and vegetables; LIQUID-CHROMATOGRAPHY; GAS-CHROMATOGRAPHY; EXTRACTION; MS/MS; VALIDATION;
D O I
10.1007/s00216-020-02844-w
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
With the increasing demand on pesticide residue laboratories to increase their scope of analysis, high-resolution accurate mass (HRAM) systems have found increasing popularity in this area. The systems have the advantage of much more reliable confirmation as high resolution increases the ability to distinguish between masses which are close together and the mass accuracy achieved limits the number of structural formulae. To date, much of the work involving these systems has revolved around developing screening methods and little has been done on use of these systems for quantitative methods. Here we describe the development and validation of a quantitative method for the analysis of 167 pesticide residues and polychlorinated biphenyls (PCBs) in samples of fruit and vegetables according to the protocol described in EU SANTE guidance document. The determination method involves analysis using a GC QExactive orbitrap in full scan mode using EI. The samples were then extracted using the standard mini-Luke method. After extraction with acetone/dichloromethane/petroleum ether 40-60 degrees C, a solvent exchange into ethyl acetate is carried out. Recovery work was carried out in cucumber, lemon and broccoli representing high water content, high acid content and high chlorophyll content commodity groups. The results show that the default MRL of 10 ppb can be achieved for more than 93% of the pesticides studied. Mass accuracy, ion ratio and matrix effect studies show that the method is robust and provides a viable alternative to triple quadrupole mass spectrometer systems for the quantification of pesticide residues in fruit and vegetable samples.
引用
收藏
页码:7113 / 7121
页数:9
相关论文
共 50 条
  • [1] Multi-residue analysis of pesticide residues and polychlorinated biphenyls in fruit and vegetables using orbital ion trap high-resolution accurate mass spectrometry
    Jim Garvey
    Tony Walsh
    Elaine Devaney
    Teresa King
    Ross Kilduff
    Analytical and Bioanalytical Chemistry, 2020, 412 : 7113 - 7121
  • [2] Multi-residue analysis of pesticide residues in fruits and vegetables using gas and liquid chromatography with mass spectrometric detection
    Christodoulou, Despo Louca
    Kourouzidou, Olympiada
    Hadjigeorgiou, Militsa
    Hadjiloizou, Panayiota
    Constantinou, Maria
    Constantinou, Panayiotis
    Kika, Koula
    Klavarioti, Maria
    ACCREDITATION AND QUALITY ASSURANCE, 2018, 23 (03) : 145 - 175
  • [3] Determination of steroid hormone residues in farmed fish using high-resolution orbital ion trap mass spectrometry
    Pan, Xiao-Dong
    Han, Jian-Long
    ANALYTICAL METHODS, 2022, 14 (41) : 4146 - 4152
  • [4] Liquid chromatography-high-resolution mass spectrometry for pesticide residue analysis in fruit and vegetables: Screening and quantitative studies
    Gomez-Ramos, M. M.
    Ferrer, C.
    Malato, O.
    Agueera, A.
    Fernandez-Alba, A. R.
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1287 : 24 - 37
  • [5] Multi-residue pesticide analysis in virgin olive oil by nanoflow liquid chromatography high resolution mass spectrometry
    Moreno-Gonzalez, David
    Alcantara-Duran, Jaime
    Addona, Silvina M.
    Beneito-Cambra, Miriam
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1562 : 27 - 35
  • [6] Multi-residue screening of veterinary drugs in egg, fish and meat using high-resolution liquid chromatography accurate mass time-of-flight mass spectrometry
    Peters, R. J. B.
    Bolck, Y. J. C.
    Rutgers, P.
    Stolker, A. A. M.
    Nielen, M. W. F.
    JOURNAL OF CHROMATOGRAPHY A, 2009, 1216 (46) : 8206 - 8216
  • [7] Shifting the paradigm in gas chromatography mass spectrometry pesticide analysis using high resolution accurate mass spectrometry
    Ucles, S.
    Ucles, A.
    Lozano, A.
    Martinez Bueno, M. J.
    Fernandez-Alba, A. R.
    JOURNAL OF CHROMATOGRAPHY A, 2017, 1501 : 107 - 116
  • [8] Multi-Residue Screening of Pesticides in Aquatic Products Using High-Performance Liquid Chromatography-Tandem High-Resolution Mass Spectrometry
    Wang, Shouying
    Yang, Guangxin
    Tang, Yunyu
    Wang, Yuan
    Shen, Xiaosheng
    Si, Wenshuai
    Yu, Huijuan
    Zhai, Wenlei
    Fodjo, Essy Kouadio
    Kong, Cong
    FOODS, 2023, 12 (06)
  • [9] Optimization and application of high-resolution gas chromatography with ion trap tandem mass spectrometry to the determination of polychlorinated biphenyls in atmospheric aerosols
    Mandalakis, M
    Tsapakis, M
    Stephanou, EG
    JOURNAL OF CHROMATOGRAPHY A, 2001, 925 (1-2) : 183 - 196
  • [10] Multi-residue pesticide analysis in soil by solid-phase disk extraction and gas chromatography ion-trap mass spectrometry
    Bao, ML
    Pantani, F
    Barbieri, K
    Burrini, D
    Griffini, O
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1996, 64 (04) : 233 - 245