Assessing the Reliability and Validity of a Shorter Walk Test Compared With the 10-Meter Walk Test for Measurements of Gait Speed in Healthy, Older Adults

被引:407
|
作者
Peters, Denise M. [1 ]
Fritz, Stacy L. [2 ]
Krotish, Debra E. [1 ]
机构
[1] Univ S Carolina, Dept Exercise Sci, Columbia, SC 29208 USA
[2] Palmetto Hlth, Div Geriatr, Columbia, SC USA
关键词
older adult; gait speed; measurement; reliability; validity; PHYSICAL PERFORMANCE-MEASURES; TRAUMATIC BRAIN-INJURY; MEANINGFUL CHANGE; BODY-COMPOSITION; CHANGE SCORES; PEOPLE; DISABILITY; STROKE; LIFE; REHABILITATION;
D O I
10.1519/JPT.0b013e318248e20d
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background and Purpose: Walking speed is associated with several health-related outcomes. Research examining how differences in test walking distance affect walking speed reliability and validity is limited. The primary purpose of this study was to examine the reliability and concurrent validity of gait speed measurements obtained from a 4-Meter Walk Test compared with the commonly used 10-Meter Walk Test. A second objective was to similarly examine 2 different timing methods: stopwatch and automatic timers. Methods: Forty-three healthy, older adults (mean age = 84.3 +/- 6.9 years) performed 3 consecutive walking trials on the 4- and 10-Meter Walk Tests at their self-selected walking speed. Results: Gait speed measurements for both tests were shown to have excellent test-retest reliability (ICC values of 0.96-0.98), with similar results for stopwatch and automatic timer assessments (ICC values of 0.99-1.00). Standard error of the measurement (SEM) values were small (0.004-0.008 m/s) across measurement methods. While the ICC value for gait speed measurements between the 2 walk tests was 0.93, the Bland-Altman analysis revealed a discrepancy of +/- 0.15 to +/- 0.17 m/s between measurement methods. Discussion: Both 4- and 10-m gait speed assessments had excellent test-retest reliability with similar SEM and minimal detectable change values. There was little difference in SEM values between the 2 timing methods. While the mean difference in gait speed between the 4- and 10-Meter Walk Tests was small, the range of the measurement differences was large enough to potentially mask meaningful changes in gait speed over time if both methods were used interchangeably. Conclusions: While the reliability of both walking tests is excellent, the 4-Meter Walk Test does not exhibit a high enough degree of concurrent validity with the 10-Meter Walk Test to be used interchangeably for gait speed assessments in healthy, older adults. We therefore recommend using the 10-Meter Walk Test to obtain the most valid clinical assessment of walking speed when using it as a 1-time indicator of health status.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 50 条
  • [21] 4-meter walk test in patients with Parkinson's disease: A reliability and validity study
    Ozkan, Taskin
    Soke, Fatih
    Ataoglu, Nigar Esra Erkoc
    Karakoc, Selda
    Gulsen, Cagri
    Kocer, Bilge
    Comoglu, Selim Selcuk
    Kaplan, Funda
    Bora, Hatice Ayse Tokcaer
    GAIT & POSTURE, 2025, 119 : 87 - 92
  • [22] Reliability, Agreement and Minimal Detectable Change of the Timed Up & Go and the 10-Meter Walk Tests in Older Patients with COPD
    Marques, Alda
    Cruz, Joana
    Quina, Sara
    Regencio, Maria
    Jacome, Cristina
    COPD-JOURNAL OF CHRONIC OBSTRUCTIVE PULMONARY DISEASE, 2016, 13 (03) : 279 - 287
  • [23] Reliability, validity and minimal detectable change of 2-min walk test and 10-m walk test in frail older adults receiving day care and residential care
    Chan, Wayne L. S.
    Pin, Tamis W.
    AGING CLINICAL AND EXPERIMENTAL RESEARCH, 2020, 32 (04) : 597 - 604
  • [24] Reliability, Validity, and Minimal Detectable Change of the Backward Walk Test in Older Adults With Dementia
    Chan, Wayne L. S.
    Cheung, Yue To
    Lee, Yin Wing
    Teo, Ai Mei
    Wo, Hui Kiu
    Wong, Yui
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2022, 45 (03) : 145 - 153
  • [25] The test-retest reliability and concurrent validity of the 3-m backward walk test and 50-ft walk test in community-dwelling older adults
    Ozden, Fatih
    Ozkeskin, Mehmet
    Bakirhan, Serkan
    Sahin, Sevnaz
    IRISH JOURNAL OF MEDICAL SCIENCE, 2022, 191 (02) : 921 - 928
  • [26] Validity and reliability of the 3-meter backward walk test in children with cerebral palsy
    Omer Faruk Celik
    Hatice Adiguzel
    Zekiye Ipek Katirci Kirmaci
    Suat Erel
    Arzu Demirguc
    Acta Neurologica Belgica, 2023, 123 : 1439 - 1446
  • [27] Validity and reliability of the 3-meter backward walk test in children with cerebral palsy
    Celik, Omer Faruk
    Adiguzel, Hatice
    Kirmaci, Zekiye Ipek Katirci
    Erel, Suat
    Demirguc, Arzu
    ACTA NEUROLOGICA BELGICA, 2023, 123 (04) : 1439 - 1446
  • [28] Investigation of the validity and reliability of the 3-meter backward walk test in high functional level adults with lower limb amputation
    Yildirim Sahan, Tezel
    Aydogan Arslan, Saniye
    Soyler, Osman
    PROSTHETICS AND ORTHOTICS INTERNATIONAL, 2024, 48 (02) : 190 - 195
  • [29] Validity and reliability of the 3-meter backward walk test in patients with multiple sclerosis
    Kirmaci, Zekiye Ipek Katirci
    Adiguzel, Hatice
    Erel, Suat
    Neyal, Ayse Munife
    Neyal, Abdurrahman
    Ergun, Nevin
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2022, 63
  • [30] Validity and reliability of the 3-meter backward walk test in mildly disabled persons with multiple sclerosis
    Bilek, Furkan
    Demir, Caner Feyzi
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2022, 58