Assessing the Reliability and Validity of a Shorter Walk Test Compared With the 10-Meter Walk Test for Measurements of Gait Speed in Healthy, Older Adults

被引:407
|
作者
Peters, Denise M. [1 ]
Fritz, Stacy L. [2 ]
Krotish, Debra E. [1 ]
机构
[1] Univ S Carolina, Dept Exercise Sci, Columbia, SC 29208 USA
[2] Palmetto Hlth, Div Geriatr, Columbia, SC USA
关键词
older adult; gait speed; measurement; reliability; validity; PHYSICAL PERFORMANCE-MEASURES; TRAUMATIC BRAIN-INJURY; MEANINGFUL CHANGE; BODY-COMPOSITION; CHANGE SCORES; PEOPLE; DISABILITY; STROKE; LIFE; REHABILITATION;
D O I
10.1519/JPT.0b013e318248e20d
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background and Purpose: Walking speed is associated with several health-related outcomes. Research examining how differences in test walking distance affect walking speed reliability and validity is limited. The primary purpose of this study was to examine the reliability and concurrent validity of gait speed measurements obtained from a 4-Meter Walk Test compared with the commonly used 10-Meter Walk Test. A second objective was to similarly examine 2 different timing methods: stopwatch and automatic timers. Methods: Forty-three healthy, older adults (mean age = 84.3 +/- 6.9 years) performed 3 consecutive walking trials on the 4- and 10-Meter Walk Tests at their self-selected walking speed. Results: Gait speed measurements for both tests were shown to have excellent test-retest reliability (ICC values of 0.96-0.98), with similar results for stopwatch and automatic timer assessments (ICC values of 0.99-1.00). Standard error of the measurement (SEM) values were small (0.004-0.008 m/s) across measurement methods. While the ICC value for gait speed measurements between the 2 walk tests was 0.93, the Bland-Altman analysis revealed a discrepancy of +/- 0.15 to +/- 0.17 m/s between measurement methods. Discussion: Both 4- and 10-m gait speed assessments had excellent test-retest reliability with similar SEM and minimal detectable change values. There was little difference in SEM values between the 2 timing methods. While the mean difference in gait speed between the 4- and 10-Meter Walk Tests was small, the range of the measurement differences was large enough to potentially mask meaningful changes in gait speed over time if both methods were used interchangeably. Conclusions: While the reliability of both walking tests is excellent, the 4-Meter Walk Test does not exhibit a high enough degree of concurrent validity with the 10-Meter Walk Test to be used interchangeably for gait speed assessments in healthy, older adults. We therefore recommend using the 10-Meter Walk Test to obtain the most valid clinical assessment of walking speed when using it as a 1-time indicator of health status.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 50 条
  • [11] Validity and Reliability of The 3-Meter Backward Walk Test in Individuals with Stroke
    Kocaman, Ayse Abit
    Arslan, Saniye Aydogan
    Ugurlu, Kubra
    Kirmaci, Zekiye Ipek Katirci
    Keskin, E. Dilek
    JOURNAL OF STROKE & CEREBROVASCULAR DISEASES, 2021, 30 (01)
  • [12] Concurrent validity of the 10-meter walk test as compared with the 6-minute walk test in patients with spinal cord injury at various levels of ability
    S Amatachaya
    S Naewla
    K Srisim
    P Arrayawichanon
    W Siritaratiwat
    Spinal Cord, 2014, 52 : 333 - 336
  • [13] Inter-rater reliability and agreement of 6 Minute Walk Test and 10 Meter Walk Test at comfortable walk speed in patients with acute stroke
    Busk, Henriette
    Holm, Paetur
    Skou, Soren
    Seitner, Simon
    Siemsen, Troels
    Wienecke, Troels
    PHYSIOTHERAPY THEORY AND PRACTICE, 2023, 39 (05) : 1024 - 1032
  • [14] Influence of timing protocols and distance covered on the outcomes of the 10-meter walk test
    Amatachaya, Sugalya
    Kwanmongkolthong, Mipattra
    Thongjumroon, Aungsana
    Boonpew, Nuttaklitta
    Amatachaya, Pipatana
    Saensook, Wilairat
    Thaweewannakij, Thiwabhorn
    Hunsawong, Torkamol
    PHYSIOTHERAPY THEORY AND PRACTICE, 2020, 36 (12) : 1348 - 1353
  • [15] Reliability and validity of the 4-meter walk test in patients with multiple sclerosis
    Ozkan, Taskin
    Unluer, Nezehat Ozgul
    Ates-Sari, Yasemin
    Hangun, Suleyman Furkan
    Vural, Gonul
    MULTIPLE SCLEROSIS AND RELATED DISORDERS, 2024, 87
  • [16] Measuring gait velocity in the elderly with a gait analysis system and a 10-meter walk test. A comparison
    Wewerka, G.
    Wewerka, G.
    Iglseder, B.
    ZEITSCHRIFT FUR GERONTOLOGIE UND GERIATRIE, 2015, 48 (01): : 29 - 34
  • [17] Test-retest reliability of the 10-meter walk test in ambulatory adults with motor-complete spinal cord injury
    Rini, Dhairiamani
    Senthilvelkumar, Thangavelu
    Noble, Koshy
    Magimairaj, Henryprakash
    INTERNATIONAL JOURNAL OF THERAPY AND REHABILITATION, 2018, 25 (07) : 335 - 339
  • [18] Concurrent Criterion Validity of a Test of Usual Gait Speed in Older Adults
    Higueras-Fresnillo, S.
    de la Camara, M. A.
    Esteban-Cornejo, I.
    Rodriguez-Artalejo, F.
    Martinez-Gomez, D.
    PERCEPTUAL AND MOTOR SKILLS, 2018, 125 (05) : 908 - 922
  • [19] Concurrent Validity of GAITRite and the 10-m Walk Test to Measure Gait Speed in Adults with Chronic Ankle Instability
    Kim, Ho
    Kum, Dongmin
    Lee, Insu
    Choi, Jongduk
    HEALTHCARE, 2022, 10 (08)
  • [20] Concurrent Validity and Test-Retest Reliability of the 3-Meter Backward Walk Test in Stroke Survivors
    Kapan, Ali
    Ristic, Milos
    Yang, Lin
    Kranz, Gottfried
    Waldhoer, Thomas
    HEALTHCARE, 2023, 11 (23)