Assessing the Reliability and Validity of a Shorter Walk Test Compared With the 10-Meter Walk Test for Measurements of Gait Speed in Healthy, Older Adults

被引:407
|
作者
Peters, Denise M. [1 ]
Fritz, Stacy L. [2 ]
Krotish, Debra E. [1 ]
机构
[1] Univ S Carolina, Dept Exercise Sci, Columbia, SC 29208 USA
[2] Palmetto Hlth, Div Geriatr, Columbia, SC USA
关键词
older adult; gait speed; measurement; reliability; validity; PHYSICAL PERFORMANCE-MEASURES; TRAUMATIC BRAIN-INJURY; MEANINGFUL CHANGE; BODY-COMPOSITION; CHANGE SCORES; PEOPLE; DISABILITY; STROKE; LIFE; REHABILITATION;
D O I
10.1519/JPT.0b013e318248e20d
中图分类号
R592 [老年病学]; C [社会科学总论];
学科分类号
03 ; 0303 ; 100203 ;
摘要
Background and Purpose: Walking speed is associated with several health-related outcomes. Research examining how differences in test walking distance affect walking speed reliability and validity is limited. The primary purpose of this study was to examine the reliability and concurrent validity of gait speed measurements obtained from a 4-Meter Walk Test compared with the commonly used 10-Meter Walk Test. A second objective was to similarly examine 2 different timing methods: stopwatch and automatic timers. Methods: Forty-three healthy, older adults (mean age = 84.3 +/- 6.9 years) performed 3 consecutive walking trials on the 4- and 10-Meter Walk Tests at their self-selected walking speed. Results: Gait speed measurements for both tests were shown to have excellent test-retest reliability (ICC values of 0.96-0.98), with similar results for stopwatch and automatic timer assessments (ICC values of 0.99-1.00). Standard error of the measurement (SEM) values were small (0.004-0.008 m/s) across measurement methods. While the ICC value for gait speed measurements between the 2 walk tests was 0.93, the Bland-Altman analysis revealed a discrepancy of +/- 0.15 to +/- 0.17 m/s between measurement methods. Discussion: Both 4- and 10-m gait speed assessments had excellent test-retest reliability with similar SEM and minimal detectable change values. There was little difference in SEM values between the 2 timing methods. While the mean difference in gait speed between the 4- and 10-Meter Walk Tests was small, the range of the measurement differences was large enough to potentially mask meaningful changes in gait speed over time if both methods were used interchangeably. Conclusions: While the reliability of both walking tests is excellent, the 4-Meter Walk Test does not exhibit a high enough degree of concurrent validity with the 10-Meter Walk Test to be used interchangeably for gait speed assessments in healthy, older adults. We therefore recommend using the 10-Meter Walk Test to obtain the most valid clinical assessment of walking speed when using it as a 1-time indicator of health status.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 50 条
  • [1] Reliability, validity and minimal detectable change of 2-minute walk test, 6-minute walk test and 10-meter walk test in frail older adults with dementia
    Chan, Wayne L. S.
    Pin, Tamis W.
    EXPERIMENTAL GERONTOLOGY, 2019, 115 : 9 - 18
  • [2] Test-Retest Reliability and Minimal Detectable Change for the 10-Meter Walk Test in Older Adults With Parkinson's disease
    Lang, Jesse T.
    Kassan, Thomas O.
    Devaney, Laurie Lee
    Colon-Semenza, Cristina
    Joseph, Michael F.
    JOURNAL OF GERIATRIC PHYSICAL THERAPY, 2016, 39 (04) : 165 - 170
  • [3] Reliability and Validity of the 10-Meter Walk Test (10MWT) in Adolescents and Young Adults with Down Syndrome
    Sanchez-Gonzalez, Juan Luis
    Llamas-Ramos, Ines
    Llamas-Ramos, Rocio
    Molina-Rueda, Francisco
    Carratala-Tejada, Maria
    Cuesta-Gomez, Alicia
    CHILDREN-BASEL, 2023, 10 (04):
  • [4] Evaluation of the validity and reliability of the 10-meter walk test using a smartphone application among Japanese older adults
    Saito, Yoshinobu
    Nakamura, Sho
    Tanaka, Ayumi
    Watanabe, Ryo
    Narimatsu, Hiroto
    Chung, Ung-il
    FRONTIERS IN SPORTS AND ACTIVE LIVING, 2022, 4
  • [5] Feasibility, criterion and construct convergent validity of the 2-minute walk test and the 10-meter walk test in an oncological context
    Reinmann, Aline
    Koessler, Thibaud
    Bodmer, Alexandre
    Baud-Grasset, Axelle
    Mentha, Geraldine
    Gligorov, Joseph
    Bruyneel, Anne-Violette
    HELIYON, 2023, 9 (11)
  • [6] Concurrent validity of walking speed measured by a wearable sensor and a stopwatch during the 10-meter walk test in individuals with stroke
    Cleland, Brice T.
    Alex, Titus
    Madhavan, Sangeetha
    GAIT & POSTURE, 2023, 107 : 61 - 66
  • [7] Gait speed in knee osteoarthritis: A simple 10-meter walk test predicts the distance covered in the 6-minute walk test
    Lozano-Meca, Jose
    Montilla-Herrador, Joaquina
    Gacto-Sanchez, Mariano
    MUSCULOSKELETAL SCIENCE AND PRACTICE, 2024, 72
  • [8] Concurrent validity of the 10-meter walk test as compared with the 6-minute walk test in patients with spinal cord injury at various levels of ability
    Amatachaya, S.
    Naewla, S.
    Srisim, K.
    Arrayawichanon, P.
    Siritaratiwat, W.
    SPINAL CORD, 2014, 52 (04) : 333 - 336
  • [9] Practice effect and cueing of 2-minute walk test, 6-minute walk test and 10-meter walk test in frail older adults with and without dementia - Recommendations to walk tests protocols
    Chan, Wayne L. S.
    Pin, Tamis W.
    EXPERIMENTAL GERONTOLOGY, 2019, 124
  • [10] Validation of stroke-specific protocols for the 10-meter walk test and 6-minute walk test conducted using 15-meter and 30-meter walkways
    Cheng, Darren K.
    Nelson, Michelle
    Brooks, Dina
    Salbach, Nancy M.
    TOPICS IN STROKE REHABILITATION, 2020, 27 (04) : 251 - 261