A comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements

被引:33
作者
Abdelgaied, A. [1 ]
Fisher, J. [1 ]
Jennings, L. M. [1 ]
机构
[1] Univ Leeds, iMBE, Leeds, W Yorkshire, England
基金
英国工程与自然科学研究理事会; 英国生物技术与生命科学研究理事会; 英国惠康基金; “创新英国”项目;
关键词
Wear; Moderately cross-linked ultra-high molecular weight polyethylene; Total knee replacements; Standard kinematics; Deep squat; Stairs ascending; MOLECULAR-WEIGHT POLYETHYLENE; IN-VITRO WEAR; CONTACT PRESSURE; CROSS-SHEAR; OBESE-PATIENTS; PREDICTION; ARTHROPLASTY; KINEMATICS; STRESS; QUANTIFICATION;
D O I
10.1016/j.jmbbm.2017.11.022
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
A more robust pre-clinical wear simulation framework is required in order to simulate wider and higher ranges of activities, observed in different patient populations such as younger more active patients. Such a framework will help to understand and address the reported higher failure rates for younger and more active patients (National_Joint_Registry, 2016). The current study has developed and validated a comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements (TKR). The input mechanical (elastic modulus and Poisson's ratio) and wear parameters of the moderately cross linked ultra-high molecular weight polyethylene (UHMWPE) bearing material were independently measured from experimental studies under realistic test conditions, similar to the loading conditions found in the total knee replacements. The wear predictions from the computational wear simulation were validated against the direct experimental wear measurements for size 3 Sigma curved total knee replacements (DePuy, UK) in an independent experimental wear simulation study under three different daily activities; walking, deep squat, and stairs ascending kinematic conditions. The measured compressive mechanical properties of the moderately cross-linked UHMWPE material were more than 20% lower than that reported in the literature under tensile test conditions. The pin-on-plate wear coefficient of moderately cross-linked UHMWPE was significantly dependant of the contact stress and the degree of cross-shear at the articulating surfaces. The computational wear predictions for the TKR from the current framework were consistent and in a good agreement with the independent full TKR experimental wear simulation measurements, with 0.94 coefficient of determination of the framework. In addition, the comprehensive combined experimental and computational framework was able to explain the complex experimental wear trends from the three different daily activities investigated. Therefore, such a framework can be adopted as a pre-clinical simulation approach to optimise different designs, materials, as well as patient's specific total knee replacements for a range of activities.
引用
收藏
页码:282 / 291
页数:10
相关论文
共 56 条
[1]  
Abdelgaied A., 2013, BONE JT J ORTHOP P S, V95
[2]  
Abdelgaied A., 2017, DATA ASS A COMPREHEN
[3]   A comparison between electromechanical and pneumatic-controlled knee simulators for the investigation of wear of total knee replacements [J].
Abdelgaied, Abdellatif ;
Fisher, John ;
Jennings, Louise M. .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 237 (07) :643-651
[4]   The effect of insert conformity and material on total knee replacement wear [J].
Abdelgaied, Abdellatif ;
Brockett, Claire L. ;
Liu, Feng ;
Jennings, Louise M. ;
Jin, Zhongmin ;
Fisher, John .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2014, 228 (01) :98-106
[5]   Quantification of the effect of cross-shear and applied nominal contact pressure on the wear of moderately cross-linked polyethylene [J].
Abdelgaied, Abdellatif ;
Brockett, Claire L. ;
Liu, Feng ;
Jennings, Louise M. ;
Fisher, John ;
Jin, Zhongmin .
PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2013, 227 (H1) :18-26
[6]   Computational wear prediction of artificial knee joints based on a new wear law and formulation [J].
Abdelgaied, Abdellatif ;
Liu, Feng ;
Brockett, Claire ;
Jennings, Louise ;
Fisher, John ;
Jin, Zhongmin .
JOURNAL OF BIOMECHANICS, 2011, 44 (06) :1108-1116
[7]   Total knee replacement in morbidly obese patients - Results of a prospective, matched study [J].
Amin, A. K. ;
Clayton, R. A. E. ;
Patton, J. T. ;
Gaston, M. ;
Cook, R. E. ;
Brenkel, I. J. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (10) :1321-1326
[8]  
[Anonymous], 2014, ISO142433
[9]  
[Anonymous], 2009, ISO142431
[10]   THE WEAR OF METALS UNDER UNLUBRICATED CONDITIONS [J].
ARCHARD, JF ;
HIRST, W .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1956, 236 (1206) :397-&