The Use of Locking Plates for Greater Trochanteric Fixation

被引:16
作者
McGrory, Brian J. [1 ]
Lucas, Romeo [1 ]
机构
[1] Orthopaed Associates Portland, Portland, ME 04104 USA
关键词
PERIPROSTHETIC FRACTURES; HIP; OSTEOLYSIS; REVISION; RECONSTRUCTION;
D O I
10.3928/01477447-20091020-27
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Stable fixation for healing of the greater trochanter after fracture or osteotomy is difficult to achieve, especially when associated with periprosthetic osteolysis. Wiring techniques are cumbersome and cable grip fixation has an unacceptable rate of nonunion, cable fraying, and production/migration of third-body debris. Using 4 case examples, we present a novel and straightforward locking plate technique that we currently use to achieve such fixation. This method also allows placement of bulk allograft that may restore trochanteric bone stock in cases of marked osteolysis. The technique uses implants that are readily available, and can be employed not only in fixation of trochanteric osteotomy but also in trochanteric advancement. At a minimum of 20 months follow-up, healing of the fracture or osteotomy with full abductor function and a significant improvement in hip score was observed in each of the 4 patients. We acknowledge that biomechanical and larger clinical studies are necessary to confirm the success of this technique, but we are pleased with our preliminary findings and continue to use this approach.
引用
收藏
页数:5
相关论文
共 16 条
[1]   THE ROLE OF TROCHANTERIC WIRE REVISION AFTER TOTAL HIP-REPLACEMENT [J].
BERNARD, AA ;
BROOKS, S .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (03) :352-354
[2]   Periprosthetic fractures associated with osteolysis - A problem on the rise [J].
Berry, DJ .
JOURNAL OF ARTHROPLASTY, 2003, 18 (03) :107-111
[3]  
Capello William N, 2008, Orthopedics, V31, P711
[4]   Fractures of the greater trochanter induced by osteolysis with the anatomic medullary locking prosthesis [J].
Claus, AM ;
Hopper, RH ;
Engh, CA .
JOURNAL OF ARTHROPLASTY, 2002, 17 (06) :706-712
[5]  
Gardner Michael J, 2007, Am J Orthop (Belle Mead NJ), V36, P460
[7]   Fractures through cystic lesions of the greater trochanter - A cause of late pain after cementless total hip arthroplasty [J].
Heekin, RD ;
Engh, CA ;
Herzwurm, PJ .
JOURNAL OF ARTHROPLASTY, 1996, 11 (06) :757-760
[8]   Fixation systems of greater trochanteric osteotomies: Biomechanical and clinical outcomes [J].
Jarit, Gregg J. ;
Sathappan, S. Sathappan ;
Panchal, Anand ;
Strauss, Eric ;
Di Cesare, Paul E. .
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2007, 15 (10) :614-624
[9]   Distal femoral fixation: A biomechanical comparison of the standard condylar buttress plate, a locked buttress plate, and the 95-degree blade plate [J].
Koval, KJ ;
Hoehl, JJ ;
Kummer, FJ ;
Simon, JA .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1997, 11 (07) :521-524
[10]   Catastrophic failure of an uncemented acetabular component due to high wear and osteolysis -: An analysis of 154 Omnifit prostheses with mean 6-year follow-up [J].
von Schewelov, T ;
Sanzén, L ;
Önsten, I ;
Carlsson, Å .
ACTA ORTHOPAEDICA SCANDINAVICA, 2004, 75 (03) :283-294