Efficient Frequency-Domain Synthetic Aperture Focusing Techniques for Imaging With a High-Frequency Single-Element Focused Transducer

被引:5
作者
Shaswary, Elyas [1 ]
Tavakkoli, Jahan [1 ,2 ]
Kumaradas, J. Carl [1 ]
机构
[1] Ryerson Univ, Dept Phys, Toronto, ON M5B 2K3, Canada
[2] St Michaels Hosp, Keenan Res Ctr Biomed Sci, Inst Biomed Engn Sci & Technol, Toronto, ON M5B 1W8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
High-frequency ultrasound; image reconstruction; synthetic aperture focusing techniques (SAFT); TRANSMIT APERTURE; MICRO-ULTRASOUND; SYSTEM; SCATTERING; MODEL; SKIN; MHZ;
D O I
10.1109/TUFFC.2018.2881726
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Synthetic aperture focusing techniques (SAFT) make the spatial resolution of the conventional ultrasound imaging from a single-element focused transducer more uniform in the lateral direction. In this work, two new frequency-domain (FD-SAFT) algorithms are proposed, which are based on the synthetic aperture radar's wavenumber algorithm, and 2-D matched filtering technique for the image reconstruction. The first algorithm is the FD-SAFT virtual source (FD-SAFT-VS) that treats the focus of a focused transducer as a virtual source having a finite size and the diffraction effect in the far-field is taken into consideration in the image reconstruction. The second algorithm is the FD-SAFT deconvolution (FD-SAFT-DE) that uses the simulated point spread function of the imaging system as a matched filter kernel in the image reconstruction. The performance of the proposed algorithms was studied using a series of simulations and experiments, and it was compared with the conventional B-mode and time-domain SAFT (TD-SAFT) imaging techniques. The image quality was analyzed in terms of spatial resolution, sidelobe level, signal-to-noise ratio (SNR), contrast resolution, contrast-to-speckle ratio, and ex vivo image quality. The results showed that the FD-SAFT-VS had the smallest spatial resolution and FD-SAFT-DE had the second smallest spatial resolution. In addition, FD-SAFT-DE had generally the largest SNR. The computation run time of FD-SAFT-VS and FD-SAFT-DE, depending on the image size, was lower by 4 to 174 times and 4 to 189 times, respectively, compared to the TD-SAFT-virtual point source.
引用
收藏
页码:57 / 70
页数:14
相关论文
共 25 条
  • [21] HIGH-FREQUENCY ULTRASOUND M-MODE IMAGING FOR IDENTIFYING LESION AND BUBBLE ACTIVITY DURING HIGH-INTENSITY FOCUSED ULTRASOUND ABLATION
    Kumon, Ronald E.
    Gudur, Madhu S. R.
    Zhou, Yun
    Deng, Cheri X.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (04) : 626 - 641
  • [22] FRET-Based Ca2+Biosensor Single Cell Imaging Interrogated by High-Frequency Ultrasound
    Yoon, Sangpil
    Pan, Yijia
    Shung, Kirk
    Wang, Yingxiao
    SENSORS, 2020, 20 (17) : 1 - 14
  • [23] Implementation of a Rotational Ultrasound Biomicroscopy System Equipped with a High-Frequency Angled Needle Transducer - Ex Vivo Ultrasound Imaging of Porcine Ocular Posterior Tissues
    Bok, Tae-Hoon
    Kim, Juho
    Bae, Jinho
    Lee, Chong Hyun
    Paeng, Dong-Guk
    SENSORS, 2014, 14 (09): : 17807 - 17816
  • [24] The Efficacy and Safety of a Single Treatment of High-Intensity, High-Frequency, Non-Focused Ultrasound Parallel Beams for Facial Acne Scars in Asian Patients: A Preliminary Study
    Boonchoo, Kanjana
    Hongcharu, Wichai
    JOURNAL OF COSMETIC DERMATOLOGY, 2025, 24 (04)
  • [25] Optically Guided High-Frequency Ultrasound Shows Superior Efficacy for Preoperative Estimation of Breslow Thickness in Comparison with Multispectral Imaging: A Single-Center Prospective Validation Study
    Varga, Noemi Nora
    Boostani, Mehdi
    Farkas, Klara
    Banvolgyi, Andras
    Lorincz, Kende
    Posta, Mate
    Lihacova, Ilze
    Lihachev, Alexey
    Medvecz, Marta
    Hollo, Peter
    Paragh, Gyorgy
    Wikonkal, Norbert M.
    Bozsanyi, Szabolcs
    Kiss, Norbert
    CANCERS, 2024, 16 (01)