Efficient Frequency-Domain Synthetic Aperture Focusing Techniques for Imaging With a High-Frequency Single-Element Focused Transducer

被引:5
作者
Shaswary, Elyas [1 ]
Tavakkoli, Jahan [1 ,2 ]
Kumaradas, J. Carl [1 ]
机构
[1] Ryerson Univ, Dept Phys, Toronto, ON M5B 2K3, Canada
[2] St Michaels Hosp, Keenan Res Ctr Biomed Sci, Inst Biomed Engn Sci & Technol, Toronto, ON M5B 1W8, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
High-frequency ultrasound; image reconstruction; synthetic aperture focusing techniques (SAFT); TRANSMIT APERTURE; MICRO-ULTRASOUND; SYSTEM; SCATTERING; MODEL; SKIN; MHZ;
D O I
10.1109/TUFFC.2018.2881726
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Synthetic aperture focusing techniques (SAFT) make the spatial resolution of the conventional ultrasound imaging from a single-element focused transducer more uniform in the lateral direction. In this work, two new frequency-domain (FD-SAFT) algorithms are proposed, which are based on the synthetic aperture radar's wavenumber algorithm, and 2-D matched filtering technique for the image reconstruction. The first algorithm is the FD-SAFT virtual source (FD-SAFT-VS) that treats the focus of a focused transducer as a virtual source having a finite size and the diffraction effect in the far-field is taken into consideration in the image reconstruction. The second algorithm is the FD-SAFT deconvolution (FD-SAFT-DE) that uses the simulated point spread function of the imaging system as a matched filter kernel in the image reconstruction. The performance of the proposed algorithms was studied using a series of simulations and experiments, and it was compared with the conventional B-mode and time-domain SAFT (TD-SAFT) imaging techniques. The image quality was analyzed in terms of spatial resolution, sidelobe level, signal-to-noise ratio (SNR), contrast resolution, contrast-to-speckle ratio, and ex vivo image quality. The results showed that the FD-SAFT-VS had the smallest spatial resolution and FD-SAFT-DE had the second smallest spatial resolution. In addition, FD-SAFT-DE had generally the largest SNR. The computation run time of FD-SAFT-VS and FD-SAFT-DE, depending on the image size, was lower by 4 to 174 times and 4 to 189 times, respectively, compared to the TD-SAFT-virtual point source.
引用
收藏
页码:57 / 70
页数:14
相关论文
共 25 条
  • [1] Synthetic Aperture Focusing for a Single-Element Transducer Undergoing Helical Motion
    Andresen, Henrik
    Nikolov, Svetoslav Ivanov
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (05) : 935 - 943
  • [2] A Single-Element Transducer with Nonuniform Thickness for High-Frequency Broadband Applications
    Liu, Jian-Hung
    Chen, Sheng-Yung
    Li, Pai-Chi
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (02) : 379 - 386
  • [3] Frequency compounded imaging with a high-frequency dual element transducer
    Chang, Jin Ho
    Kim, Hyung Ham
    Lee, Jungwoo
    Shung, K. Kirk
    ULTRASONICS, 2010, 50 (4-5) : 453 - 457
  • [4] Design of High-frequency Ultrasound Focused Transducer
    Lu Chao
    Jin Cui'e
    Li Ling
    Lu Minghui
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOLS 1 - 4, 2010, : 908 - 913
  • [5] Sensitivity analysis of synthetic aperture focusing based on the virtual source point for high-frequency ultrasound imaging
    Pekam, Fabrice Chuembou
    Vollborn, Thorsten
    Tinschert, Joachim
    Wolfart, Stefan
    Radermacher, Klaus
    Heger, Stefan
    2012 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2012,
  • [6] Photoacoustic Imaging of Nanoparticle-Containing Cells Using Single-Element Focused Transducer: A Simulation Study
    Karmakar, Subhajit
    Roy, Madhusudan
    Saha, Ratan K.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2015, 62 (03) : 463 - 474
  • [7] Computational Complexity Reduction of Synthetic-aperture Focus in Ultrasound Imaging Using Frequency-domain Reconstruction
    Moghimirad, Elahe
    Mahloojifar, Ali
    Asl, Babak Mohammadzadeh
    ULTRASONIC IMAGING, 2016, 38 (03) : 175 - 193
  • [8] Synthetic Aperture Imaging Using High-Frequency Convex Array for Ophthalmic Ultrasound Applications
    Lim, Hae Gyun
    Kim, Hyung Ham
    Yoon, Changhan
    SENSORS, 2021, 21 (07)
  • [9] Numerical Study and Optimisation of a Novel Single-Element Dual-Frequency Ultrasound Transducer
    Sun, Changhe
    Jiang, Senlin
    Liu, Yufei
    SENSORS, 2018, 18 (03):
  • [10] A High-Frequency Ultrasound Imaging System Combining Limited-Angle Spatial Compounding and Model-Based Synthetic Aperture Focusing
    Opretzka, Joern
    Vogt, Michael
    Ermert, Helmut
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2011, 58 (07) : 1355 - 1365