TOWARDS THE DEVELOPMENT OF A NEW TENDON-DRIVEN MINIMALLY INVASIVE NEUROSURGICAL INTRACRANIAL ROBOT

被引:0
作者
Zhao, Wenxue [1 ]
Desai, Jaydev P. [1 ]
机构
[1] Univ Maryland, Dept Mech Engn, Robot Automat & Med Syst RAMS Lab, College Pk, MD 20742 USA
来源
7TH ANNUAL DYNAMIC SYSTEMS AND CONTROL CONFERENCE, 2014, VOL 1 | 2014年
关键词
SURGERY; DESIGN; FORCE;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Surgical resection of deep intracranial tumors under image guidance has significant challenges. The surgeon cannot see beyond the line of sight and it is also difficult to avoid the functional nerves along the path. In this context, the design of a Minimally Invasive Neurosurgical Intracranial Robot (MINIR-II) under continuous MRI is critical. The primary goal of the overall procedure is to avoid critical brain structures to reach the tumor location. Upon reaching the tumor location, the electro-cautery at the robot tip should be controlled to resect the tumor. The new MINIR-II proposed in this work,though not yet MRI compatible, is a dexterous serial chain tendon-driven robot with larger inner space, smaller outer diameter, and less coupling effect of the tendons during actuation. Each joint of the robot was attached with two tendons and they were routed outside the robot around a pulley to achieve rotational degree of freedom. The four-joint assembled robot was manufactured using a rapid prototyping machine and was tested by an experimental setup to demonstrate the motion of the robot.
引用
收藏
页数:8
相关论文
共 34 条
[1]  
Anor Tomer, 2011, IEEE Int Conf Robot Autom, P667, DOI 10.1109/ICRA.2011.5980311
[2]  
Ayvali E., 2014, Experimental Robotics, P115
[3]   Pulse width modulation-based temperature tracking for feedback control of a shape memory alloy actuator [J].
Ayvali, Elif ;
Desai, Jaydev P. .
JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 2014, 25 (06) :720-730
[4]  
Ayvali E, 2012, P IEEE RAS-EMBS INT, P50, DOI 10.1109/BioRob.2012.6290891
[5]  
Ayvali E, 2012, IEEE INT CONF ROBOT, P1614, DOI 10.1109/ICRA.2012.6225312
[6]   Towards a discretely actuated steerable cannula for diagnostic and therapeutic procedures [J].
Ayvali, Elif ;
Liang, Chia-Pin ;
Ho, Mingyen ;
Chen, Yu ;
Desai, Jaydev P. .
INTERNATIONAL JOURNAL OF ROBOTICS RESEARCH, 2012, 31 (05) :588-603
[7]  
Butterfass J, 2001, IEEE INT CONF ROBOT, P109, DOI 10.1109/ROBOT.2001.932538
[8]   APPLICATION OF CONTRAST AGENTS IN CT AND MRI (NMR) - THEIR POTENTIAL IN IMAGING OF BRAIN-TUMORS [J].
CLAUSSEN, C ;
LANIADO, M ;
KAZNER, E ;
SCHORNER, W ;
FELIX, R .
NEURORADIOLOGY, 1985, 27 (02) :164-171
[9]  
Davies B.L., 1996, Computer-Integrated Surgery: Technology and Clinical Applications, P593
[10]  
Ghodoussi M, 2002, 2002 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS I-IV, PROCEEDINGS, P1882, DOI 10.1109/ROBOT.2002.1014815