Background: To compare the results of HbA1c determination obtained through immunoassays versus the HPLC method currently used routinely in our laboratory. Methods: We evaluated immunoturbidimetric assays for the HbA1c measure on three analyzers, specifically the Roche Cobas Integra 400+(R) (Roche Diagnostics, Indianapolis, IN, USA), Ortho Clinical Diagnostics Vitros 5.1 FS (R) (Ortho Clinical Diagnostics, NY, USA), and Siemens Dimension RxL (R) (Siemens Healthcare Diagnostics, NY, USA), in comparison with the HPLC Menarini HA 8140 (R) (Menarini Diagnostics, Rungis, France) currently used in our laboratory. Results: Analytical performances including precision, analytical range, recovery, carryover, erythrosedimentation and comparison studies were acceptable leading to results with a level of exactitude in accordance with the recommendations of the National Glycohemoglobin Standardization Program (NGSP). Conclusions: The three immunoassays tested can be used interchangeably and will be satisfactory for laboratories who cannot invest in a HPLC analyzer. (Clin. Lab. 2012;58:1171-1177. DOI: 10.7754/Clin.Lab.2012.111222)
引用
收藏
页码:1171 / 1177
页数:7
相关论文
共 50 条
  • [1] Evaluation and interference study of hemoglobin A1c measured by turbidimetric inhibition immunoassay
    Chang, J
    Hoke, C
    Ettinger, B
    Penerian, G
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 1998, 109 (03) : 274 - 278
  • [2] Comparison of Hemoglobin A1c Measurements of Samples With Elevated Fetal Hemoglobin by Three Commercial Assays
    Shu, Irene
    Devaraj, Sridevi
    Hanson, Steven E.
    Little, Randie R.
    Wang, Ping
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 (03) : 466 - 466
  • [3] Comparison of hemoglobin A1c measurements of samples with elevated fetal hemoglobin by three commercial assays
    Shu, Irene
    Devaraj, Sridevi
    Hanson, Steven E.
    Little, Randie R.
    Wang, Ping
    CLINICA CHIMICA ACTA, 2012, 413 (19-20) : 1712 - 1713
  • [4] Evaluation of Alternate Hemoglobin A1c Assays for Use in a Population with a High Prevalence of Hemoglobin Variants
    Stevens, K. S.
    Koch, D.
    Young, A.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2013, 140 (03) : 435 - 435
  • [5] Hemoglobin A1C assays and hemoglobinopathies:: problems and strategies
    Gillery, P
    Hue, G
    Bordas-Fonfrède, M
    Chapelle, JP
    Drouin, P
    Lévy-Marchal, C
    Périer, C
    Sélam, JL
    Slama, G
    Thivolet, C
    Vialettes, B
    ANNALES DE BIOLOGIE CLINIQUE, 2000, 58 (04) : 425 - 429
  • [6] FAST AND ACCURATE DETERMINATION OF HEMOGLOBIN A1C USING AN AUTOMATED SAMPLE PROCESSOR
    DUTRIEU, J
    DELMOTTE, YA
    DELANNOY, P
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1985, 321 (02): : 180 - 184
  • [7] Comparative evaluation of three assay systems for automated determination of hemoglobin A(1c)
    HalwachsBaumann, G
    Katzensteiner, S
    Schnedl, W
    Purstner, P
    Pieber, T
    WildersTruschnig, M
    CLINICAL CHEMISTRY, 1997, 43 (03) : 511 - 517
  • [8] Evaluation of three hemoglobin A1c point-of-care instruments
    Criel, M.
    Jonckheere, S.
    Langlois, M.
    ACTA CLINICA BELGICA, 2015, 70 : S3 - S3
  • [9] Analytical performance evaluation of three methods for hemoglobin A1c quantification
    Unger, Gisela
    Ruiz, Gustavo
    Milano, Pablo
    Fabiana Benozzi, Silvia
    Laura Pennacchiotti, Graciela
    ACTA BIOQUIMICA CLINICA LATINOAMERICANA, 2014, 48 (02): : 183 - 189
  • [10] Evaluation of Three Hemoglobin A1c Point-of-Care Instruments
    Criel, Marieke
    Jonckheere, Stijn
    Langlois, Michel
    CLINICAL LABORATORY, 2016, 62 (03) : 285 - 291