Continuous ambulatory hand force monitoring during manual materials handling using instrumented force shoes and an inertial motion capture suit

被引:25
作者
Faber, G. S. [1 ,2 ,3 ]
Koopman, A. S. [1 ]
Kingma, I. [1 ]
Chang, C. C. [3 ,4 ]
Dennerlein, J. T. [2 ,5 ]
van Dieen, J. H. [1 ]
机构
[1] Vrije Univ Amsterdam, Fac Behav & Movement Sci, Dept Human Movement Sci, Amsterdam Movement Sci, Amsterdam, Netherlands
[2] Harvard TH Chan Sch Publ Hlth, Dept Environm Hlth, Boston, MA USA
[3] Liberty Mutual Res Inst Safety, Hopkinton, MA USA
[4] Natl Tsing Hua Univ, Dept Ind Engn & Engn Management, Taipei, Taiwan
[5] Northeastern Univ, Dept Phys Therapy Movement & Rehabil Sci, Boston, MA 02115 USA
关键词
Wearable sensors; Occupational biomechanics; Ergonomics; Inertial measurement unit (IMU); Spine; GROUND REACTION FORCES; LOW-BACK; VALIDATION; MOMENTS; OBJECT; WORK; LOAD;
D O I
10.1016/j.jbiomech.2017.10.006
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Hand forces (HFs) are commonly measured during biomechanical assessment of manual materials handling; however, it is often a challenge to directly measure HFs in field studies. Therefore, in a previous study we proposed a HF estimation method based on ground reaction forces (GRFs) and body segment accelerations and tested it with laboratory equipment: GFRs were measured with force plates (FPs) and segment accelerations were measured using optical motion capture (OMC). In the current study, we evaluated the HF estimation method based on an ambulatory measurement system, consisting of inertial motion capture (IMC) and instrumented force shoes (FSs). Sixteen participants lifted and carried a 10-kg crate from ground level while 3D full-body kinematics were measured using OMC and IMC, and 3D GRFs were measured using FPs and FSs. We estimated 3D hand force vectors based on: (1) FP+OMC, (2) FP+IMC and (3) FS+IMC. We calculated the root-mean square differences (RMSDs) between the estimated HFs to reference HFs calculated based on crate kinematics and the GRFs of a FP that the crate was lifted from. Averaged over subjects and across 3D force directions, the HF RMSD ranged between 10-15N when using the laboratory equipment (FP + OMC), 11-18N when using the IMC instead of OMC data (FP +IMC), and 17-21N when using the FSs in combination with IMC (FS + IMC). This error is regarded acceptable for the assessment of spinal loading during manual lifting, as it would results in less than 5% error in peak moment estimates. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:235 / 241
页数:7
相关论文
共 28 条
[1]   Cumulative Low Back Load at Work as a Risk Factor of Low Back Pain: A Prospective Cohort Study [J].
Coenen, Pieter ;
Kingma, Idsart ;
Boot, Cecile R. L. ;
Twisk, Jos W. R. ;
Bongers, Paulien M. ;
van Dieen, Jaap H. .
JOURNAL OF OCCUPATIONAL REHABILITATION, 2013, 23 (01) :11-18
[2]   Estimation of low back moments from video analysis: A validation study [J].
Coenen, Pieter ;
Kingma, Idsart ;
Boot, Cecile R. L. ;
Faber, Gert S. ;
Xu, Xu ;
Bongers, Paulien M. ;
van Dieen, Jaap H. .
JOURNAL OF BIOMECHANICS, 2011, 44 (13) :2369-2375
[3]   Adjustments to Zatsiorsky-Seluyanov's segment inertia parameters [J].
de Leva, P .
JOURNAL OF BIOMECHANICS, 1996, 29 (09) :1223-1230
[4]   Spinal loads during individual and team lifting [J].
Dennis, GJ ;
Barrett, RS .
ERGONOMICS, 2002, 45 (10) :671-681
[5]   The effects of ergonomic interventions on low back moments are attenuated by changes in lifting behaviour [J].
Faber, G. S. ;
Kingma, I. ;
Van Dieen, J. H. .
ERGONOMICS, 2007, 50 (09) :1377-1391
[6]   Working height, block mass and one- vs. two-handed block handling: the contribution to low back and shoulder loading during masonry work [J].
Faber, G. S. ;
Kingma, I. ;
Kuijer, P. P. F. M. ;
van der Molen, H. F. ;
Hoozemans, M. J. M. ;
Frings-Dresen, M. H. W. ;
van Dieen, J. H. .
ERGONOMICS, 2009, 52 (09) :1104-1118
[7]  
Faber G.S., 2015, J BIOMECH
[8]   Estimating dynamic external hand forces during manual materials handling based on ground reaction forces and body segment accelerations [J].
Faber, Gert S. ;
Chang, Chien-Chi ;
Kingma, Idsart ;
Dennerlein, Jack T. .
JOURNAL OF BIOMECHANICS, 2013, 46 (15) :2736-2740
[9]   Lifting style and participant's sex do not affect optimal inertial sensor location for ambulatory assessment of trunk inclination [J].
Faber, Gert S. ;
Chang, Chien-Chi ;
Kingma, Idsart ;
Dennerlein, Jack T. .
JOURNAL OF BIOMECHANICS, 2013, 46 (05) :1027-1030
[10]   A force plate based method for the calibration of force/torque sensors [J].
Faber, Gert S. ;
Chang, Chien-Chi ;
Kingma, Idsart ;
Schepers, H. Martin ;
Herber, Sebastiaan ;
Veltink, Peter H. ;
Dennerlein, Jack T. .
JOURNAL OF BIOMECHANICS, 2012, 45 (07) :1332-1338