Hypoxia imaging with the nitroimidazole 18F-FAZA PET tracer: A comparison with OxyLite, EPR oximetry and 19F-MRI relaxometry

被引:65
作者
Ly-Binh-An Tran
Bol, Anne [2 ]
Labar, Daniel [2 ]
Jordan, Benedicte
Magat, Julie
Mignion, Lionel
Gregoire, Vincent [2 ]
Gallez, Bernard [1 ]
机构
[1] Catholic Univ Louvain, Louvain Drug Res Inst, Biomed Magnet Resonance Grp REMA, B-1200 Brussels, Belgium
[2] Catholic Univ Louvain, Inst Expt & Clin Res, B-1200 Brussels, Belgium
关键词
Tumor hypoxia; F-18-FAZA; PET; EPR; MRI; OxyLite; ELECTRON-PARAMAGNETIC-RESONANCE; SQUAMOUS-CELL CARCINOMA; TUMOR OXYGENATION; IN-VIVO; RADIATION-THERAPY; ADVANCED CANCER; PO(2); HEAD; NECK; RADIOTHERAPY;
D O I
10.1016/j.radonc.2012.04.011
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background and purpose: F-18-FAZA is a nitroimidazole PET tracer that can provide images of tumor hypoxia. However, it cannot provide absolute pO(2) values. To qualify F-18-FAZA PET, we compared PET images to pO(2) measured by OxyLite. EPR oximetry and F-19-MRI. Materials and methods: Male WAG/Rij rats grafted with rhabdomyosarcoma were used. Tumor oxygenation was modified by gas breathing (air or carbogen). The same day of PET acquisition, the pO(2) was measured in the same tumor either by OxyLite probes (measurement at 10 different sites), EPR oximetry using low frequency EPR or F-19-relaxometry using 15C5 on an 11.7 T MR system. Results: There was a good correlation between the results obtained by PET and EPR (R = 0.93). In the case of OxyLite, although a weaker correlation was observed (R = 0.55), the trend for two values to agree was still related to the inverse function theoretically predicted. For the comparison of F-18-FAZA PET and F-19-MRI, no change in T-1 was observed. Conclusions: A clear correlation between F-18-FAZA PET image intensities and tumor oxygenation was demonstrated, suggesting that F-18-FAZA PET is a promising imaging technique to guide cancer therapy. (C) 2012 Elsevier Ireland Ltd. All rights reserved. Radiotherapy and Oncology 105 (2012) 29-35
引用
收藏
页码:29 / 35
页数:7
相关论文
共 65 条
[1]   Theory, Instrumentation, and Applications of Electron Paramagnetic Resonance Oximetry [J].
Ahmad, Rizwan ;
Kuppusamy, Periannan .
CHEMICAL REVIEWS, 2010, 110 (05) :3212-3236
[2]   Effect of anesthesia on the signal intensity in tumors using BOLD-MRI: Comparison with flow measurements by laser Doppler flowmetry and oxygen measurements by luminescence-based probes [J].
Baudelet, C ;
Gallez, B .
MAGNETIC RESONANCE IMAGING, 2004, 22 (07) :905-912
[3]   How does blood oxygen level-dependent (BOLD) contrast correlate with oxygen partial pressure (pO2) inside tumors? [J].
Baudelet, C ;
Gallez, B .
MAGNETIC RESONANCE IN MEDICINE, 2002, 48 (06) :980-986
[4]   Molecular Imaging-Based Dose Painting: A Novel Paradigm for Radiation Therapy Prescription [J].
Bentzen, Soren M. ;
Gregoire, Vincent .
SEMINARS IN RADIATION ONCOLOGY, 2011, 21 (02) :101-110
[5]   Comparison of tumor and normal tissue oxygen tension measurements using OxyLite or microelectrodes in rodents [J].
Braun, RD ;
Lanzen, JL ;
Snyder, SA ;
Dewhirst, MW .
AMERICAN JOURNAL OF PHYSIOLOGY-HEART AND CIRCULATORY PHYSIOLOGY, 2001, 280 (06) :H2533-H2544
[6]   Imaging hypoxia in xenografted and murine tumors with 18F-fluoroazomycin arabinoside:: A comparative study involving micropet, autoradiography, Po2-polarography, and fluorescence microscopy [J].
Busk, Morten ;
Horsman, Michael R. ;
Jakobsen, Steen ;
Keiding, Susanne ;
van der Kogel, Albert J. ;
Bussink, Johan ;
Overgaard, Jens .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2008, 70 (04) :1202-1212
[7]   Can hypoxia-PET map hypoxic cell density heterogeneity accurately in an animal tumor model at a clinically obtainable image contrast? [J].
Busk, Morten ;
Horsman, Michael R. ;
Jakobsen, Steen ;
Hansen, Kim V. ;
Bussink, Johan ;
van der Kogel, Albert ;
Overgaard, Jens .
RADIOTHERAPY AND ONCOLOGY, 2009, 92 (03) :429-436
[8]   Cellular uptake of PET tracers of glucose metabolism and hypoxia and their linkage [J].
Busk, Morten ;
Horsman, Michael R. ;
Jakobsen, Steen ;
Bussink, Johan ;
van der Kogel, Albert ;
Overgaard, Jens .
EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 (12) :2294-2303
[9]   A robotic system for 18F-FMISO PET-guided intratumoral pO2 measurements [J].
Chang, Jenghwa ;
Wen, Bixiu ;
Kazanzides, Peter ;
Zanzonico, Pat ;
Finn, Ronald D. ;
Fichtinger, Gabor ;
Ling, C. Clifton .
MEDICAL PHYSICS, 2009, 36 (11) :5301-5309
[10]   Planning study for available dose of hypoxic tumor volume using fluorine-18-labeled fluoromisonidazole positron emission tomography for treatment of the head and neck cancer [J].
Choi, Wonsik ;
Lee, Sang-wook ;
Park, Sung Ho ;
Ryu, Jin Sook ;
Oh, Seung Joon ;
Im, Ki Chun ;
Choi, Eun Kyung ;
Kim, Jong Hoon ;
Jung, Sang Hoon ;
Kim, Sookon ;
Do Ahn, Seung .
RADIOTHERAPY AND ONCOLOGY, 2010, 97 (02) :176-182