The routine leukocyte differential flow cytometry HematoFlow method: A new flagging system for automatic validation

被引:12
作者
Allou, Kaoutar [1 ]
Vial, Jean-Philippe [1 ]
Bene, Marie C. [2 ]
Lacombe, Francis [1 ]
机构
[1] Univ Hosp Bordeaux, Haut Leveque Hosp, Pessac, France
[2] Univ Hosp Nantes, Nantes, France
关键词
flow cytometry; hematology; immunophenotyping; multiparameter analysis; peripheral blood; BLOOD; ENUMERATION;
D O I
10.1002/cyto.b.21242
中图分类号
R446 [实验室诊断]; R-33 [实验医学、医学实验];
学科分类号
1001 ;
摘要
The complete blood cell count and white blood cell differential are the first step in the biological diagnosis of hematological diseases. Both are currently performed by automated instruments which control data and produce alerts. If such flags are activated, the automated differential cannot be validated and the operator must activate a visual blood smear review. Microscopic examination is still today the reference method despite its lack of sensitivity and reproducibility. The HematoFlow (Beckman Coulter) system is the first flow cytometry commercialized method designed for the routine differential. Using six markers in five colors and an automated gating strategy, it provides differentials proven to be reliable for 17 leukocyte subpopulations detection. Relying first on a retrospective analysis of 6,462 blood samples processed by HematoFlow, thresholds were determined to detect the presence of immature granulocytes and/or blast cells. All possible gating strategy misclassifications of leukocyte subpopulations were then summarized in a systematic nomenclature leading to the development of an original flag system based on the detection of aberrant localization of cell events in specific new bivariate histograms. Ultimately, more than 50% of the results could be automatically validated using the HematoFlow system, without any false negative, thereby dramatically contributing to an important decrease of technicians' workload. Moreover a noticeable help was given for smear review interpretation and new immunological flags led to the confirmation of blood disease after classical immunophenotyping. These results were confirmed in a second prospective study including 15,335 cases, where more than 50% of the results were automatically validated by this new flag system. MFC stands as being more and more essential for analyzing differentials in routine and this new flag system could greatly improve its implementation. (c) 2015 International Clinical Cytometry Society
引用
收藏
页码:375 / 384
页数:10
相关论文
共 17 条
[1]  
[Anonymous], LAB HEMATOLOGY PRACT
[2]  
[Anonymous], 2010, H20A2 CLSI
[3]   Total nucleated cell differential for blood and bone marrow using a single tube in a five-color flow cytometer [J].
Bjornsson, Sven ;
Wahlstrom, Saga ;
Norstrom, Eva ;
Bernevi, Ingela ;
O'Neill, Ulla ;
Johansson, Eva ;
Runstrom, Hakan ;
Simonsson, Per .
CYTOMETRY PART B-CLINICAL CYTOMETRY, 2008, 74B (02) :91-103
[4]   Evaluation of an 8-Color Flow Cytometric Reference Method for White Blood Cell Differential Enumeration [J].
Cherian, Sindhu ;
Levin, Greg ;
Lo, Wing Yin ;
Mauck, Megan ;
Kuhn, Donald ;
Lee, Crystol ;
Wood, Brent L. .
CYTOMETRY PART B-CLINICAL CYTOMETRY, 2010, 78B (05) :319-328
[5]   Physiologic variations in granulocytic surface antigen expression: impact of age, gender, pregnancy, race, and stress [J].
Elghetany, MT ;
Lacombe, F .
JOURNAL OF LEUKOCYTE BIOLOGY, 2004, 75 (02) :157-162
[6]   6 markers/5 colors extended white blood cell differential by flow cytornetry [J].
Faucher, Jean-Luc ;
Lacronique-Gazaille, Charlotte ;
Frebet, Elise ;
Trimoreau, Franck ;
Donnard, Magali ;
Bordessoule, Dominique ;
Lacombe, Francis ;
Feuillard, Jean .
CYTOMETRY PART A, 2007, 71A (11) :934-944
[7]  
Fujimoto H, 2000, CYTOMETRY, V42, P371, DOI 10.1002/1097-0320(20001215)42:6<371::AID-CYTO1004>3.0.CO
[8]  
2-G
[9]   Reliable, Accurate Determination of the Leukocyte Differential of Leukopenic Samples by Using Hematoflow Method [J].
Jo, Yongjun ;
Kim, Soo Hwa ;
Koh, Kwangsang ;
Park, Jongmoon ;
Shim, Yang Bo ;
Lim, Jihyang ;
Kim, Yonggoo ;
Park, Yeon-Joon ;
Han, Kyungja .
KOREAN JOURNAL OF LABORATORY MEDICINE, 2011, 31 (03) :131-137
[10]   Evaluation of the leukocyte differential on a new automated flow cytometry hematology analyzer [J].
Kim, J. -E. ;
Kim, B. -R. ;
Woo, K. -S. ;
Han, J. -Y. .
INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2012, 34 (05) :547-550