Mesopic increment detection sensitivity, Part 2: Modelling mesopic detection sensitivity

被引:0
|
作者
Englisch, D. [1 ]
Bodrogi, P. [1 ]
Schiller, C. [1 ]
Khanh, T. Q. [1 ]
机构
[1] Tech Univ Darmstadt, Lab Lighting Technol, Hsch Str 4A, D-64289 Darmstadt, Germany
关键词
D O I
10.1177/1477153516667769
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper deals with the modelling of the mesopic detection sensitivity data described in Part 1. The modelling is based on a linear combination of the spectral sensitivity templates of four retinal mechanisms (long + medium wavelength sensitive cones, rods, short wavelength sensitive cones and long - medium wavelength sensitive cones opponency) to describe the experimental data on mesopic detection sensitivity and to provide a practically usable model. Model parameters representing the weighting of these mechanisms are analysed as a function of target eccentricity and background luminance.
引用
收藏
页码:376 / 389
页数:14
相关论文
共 50 条
  • [1] Mesopic increment detection sensitivity, Part I: Phenomenological analysis
    Englisch, D.
    Schiller, C.
    Bodrogi, P.
    Khanh, T. Q.
    LIGHTING RESEARCH & TECHNOLOGY, 2018, 50 (03) : 360 - 375
  • [2] Mesopic contrast sensitivity: what is normal?
    Haughom, B.
    Strand, T-E
    ACTA OPHTHALMOLOGICA, 2010, 88 : 17 - 17
  • [3] Glare Impact on Mesopic Contrast Sensitivity
    Papadatou, Eleni
    Vilupuru, Srividhya
    Alarcon, Aixa
    Tsai, Linda
    Canovas, Carmen
    Thomas, Eugenia
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2023, 64 (08)
  • [4] Temporal retinal sensitivity in mesopic adaptation
    Matesanz, Beatriz M.
    Issolio, Luis
    Arranz, Isabel
    de la Rosa, Cristina
    Menendez, Jose A.
    Mar, Santiago
    Aparicio, Juan A.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2011, 31 (06) : 615 - 624
  • [5] Measurements of chromatic sensitivity in the mesopic range
    Walkey, HC
    Barbur, JL
    Harlow, JA
    Makous, W
    COLOR RESEARCH AND APPLICATION, 2001, 26 : S36 - S42
  • [6] Mesopic contrast sensitivity functions in amblyopic children
    Lew, H
    Seong, GJ
    Kim, SK
    Lee, JB
    Han, SH
    YONSEI MEDICAL JOURNAL, 2003, 44 (06) : 995 - 1000
  • [7] Effect of glare on mesopic contrast sensitivity function
    Yu, Deyue
    Perry, Landon
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2024, 65 (07)
  • [8] Comparison of contrast sensitivity in photopic and mesopic conditions
    Healy, Claire Rose
    Ng, Edward Deon
    Diep, My
    Seitz, Aaron
    Davey, Pinakin Gunvant
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [9] Mesopic spectral sensitivity derived from reaction times
    Walkey, HC
    Harlow, JA
    Barbur, JL
    PERCEPTION, 2004, 33 : 44 - 44
  • [10] Oxygenation State and Mesopic Sensitivity to Dynamic Contrast Stimuli
    Connolly, Desmond M.
    Hosking, Sarah L.
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (12) : 1368 - 1375