Effect of Bearing Type on Taper Material Loss in Hips From 1 Manufacturer

被引:7
|
作者
Hothi, Harry S. [1 ,2 ]
Eskelinen, Antti P. [3 ]
Henckel, Johann [1 ,2 ]
Kwon, Young-Min [4 ]
Blunn, Gordon W. [1 ,2 ]
Skinner, John A. [1 ,2 ]
Hart, Alister J. [1 ,2 ]
机构
[1] Univ Coll London, Inst Orthopaed & Musculoskeletal Sci, Stanmore, Middx, England
[2] Royal Natl Orthopaed Hosp, Stanmore, Middx, England
[3] Coxa Hosp Joint Replacement, Tampere, Finland
[4] Harvard Med Sch, Massachusetts Gen Hosp, Boston, MA USA
来源
JOURNAL OF ARTHROPLASTY | 2018年 / 33卷 / 05期
关键词
hip; taper; metal-on-polyethylene; corrosion; wear; ARTHROPLASTY; CORROSION; TRUNNIONOSIS; RETRIEVAL; IMPLANTS; JUNCTION;
D O I
10.1016/j.arth.2017.12.022
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Numerous studies have reported on clinical significant volumes of material loss and corrosion at the head-stem junction of metal-on-metal (MOM) hips; less is understood about metal-onpolyethylene (MOP) hips. We compared the effect of bearing type (MOM vs MOP) on taper material loss for a hip system of a single design. Methods: In this cohort study, we recruited retrieved MOM (n = 30) and MOP (n = 22) bearing hips that were consecutively received at our center. We prospectively collected associated clinical and imaging data. We measured the severity of corrosion and volumes of material loss at each head taper surface and used multivariate statistical analysis to investigate differences between the 2 bearing types. Results: The median rate of material loss for the MOM and MOP groups was 0.81 mm(3)/y (0.01-3.45) and 0.03 mm(3)/y (0-1.07), respectively (P <.001). Twenty-nine of 30 MOM hips were revised for adverse metal reactions, compared with 1 of 22 MOP hips. Conclusion: MOP hips lost significantly less material from their taper junctions than MOM hips. Our results can reassure patients with MOP Pinnacle hips that they are unlikely to experience clinically significant problems related to material loss from the taper junction. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:1588 / 1593
页数:6
相关论文
共 50 条
  • [31] Effect of MoS2on Iron-Based Friction Material Prepared Directly from Vanadium-Bearing Titanomagnetite Concentrates
    Zhang, Yanyan
    Feng, Keqin
    Shui, Yue
    METALS AND MATERIALS INTERNATIONAL, 2020, 26 (07) : 1070 - 1078
  • [32] Inhaled insulin treatment for Type 1 diabetes, following major skin loss from necrotising fasciitis
    Maguire, D.
    Bodansky, H. J.
    DIABETIC MEDICINE, 2008, 25
  • [33] Loss of activities for mRNA synthesis accompanies loss of λ2 spikes from reovirus cores:: An effect of λ2 on λ1 shell structure
    Luongo, CL
    Zhang, X
    Walker, SB
    Chen, Y
    Broering, TJ
    Farsetta, DL
    Bowman, VD
    Baker, TS
    Nibert, ML
    VIROLOGY, 2002, 296 (01) : 24 - 38
  • [34] Effect of furnish type and high-density raw material from mill residues on properties of particleboard panels
    Rofii, Muhammad Navis
    Yumigeta, Satomi
    Kojima, Yoichi
    Suzuki, Shigehiko
    JOURNAL OF WOOD SCIENCE, 2013, 59 (05) : 402 - 409
  • [35] Effect of furnish type and high-density raw material from mill residues on properties of particleboard panels
    Muhammad Navis Rofii
    Satomi Yumigeta
    Yoichi Kojima
    Shigehiko Suzuki
    Journal of Wood Science, 2013, 59 : 402 - 409
  • [36] Effect of guide sleeve material, region, diameter, and number of times drills were used on the material loss from sleeves and drills used for surgical guides: An in vitro study
    Ozan, Oguz
    Seker, Emre
    Cakmak, Gulce
    Guo, Xiaohan
    Yilmaz, Burak
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 128 (04): : 746 - 753
  • [37] Loss of IDO1 Expression From Human Pancreatic -Cells Precedes Their Destruction During the Development of Type 1 Diabetes
    Anquetil, Florence
    Mondanelli, Giada
    Gonzalez, Nathaly
    Calvo, Teresa Rodriguez
    Gonzalo, Jose Zapardiel
    Krogvold, Lars
    Dahl-Jorgensen, Knut
    Van den Eynde, Benoit
    Orabona, Ciriana
    Grohmann, Ursula
    von Herrath, Matthias G.
    DIABETES, 2018, 67 (09) : 1858 - 1866
  • [38] Is the relative protective effect of maternal vs paternal type 1 diabetes on risk of type 1 diabetes explained by differences in predisposing genes potentially induced by selective foetal loss?
    Tapia, G.
    Rantala, A. -K.
    Page, C.
    Skrivarhaug, T.
    Lund-Blix, N.
    Stordal, K.
    Stene, L.
    DIABETOLOGIA, 2024, 67 : S18 - S19
  • [39] Effect of Ni Content on Iron-based Friction Material Prepared by In-situ Synthesized from Vanadium-bearing Titanomagnetite Concentrates
    Shui Yue
    Feng Ke-qin
    Yue Hui-fang
    Zhang Yan-yan
    Yan Zi-di
    CAILIAO GONGCHENG-JOURNAL OF MATERIALS ENGINEERING, 2018, 46 (09): : 73 - 79
  • [40] Effect of chronic lithium on mechanical sensitivity and trabecular bone loss induced by type-1 diabetes mellitus in mice
    Mayra Alejandra Graniel-Amador
    Héctor Fabian Torres-Rodríguez
    Ruth Elena Martínez-Mendoza
    Virginia Margarita Vargas-Muñoz
    Rosa Issel Acosta-González
    Gabriela Castañeda-Corral
    Enriqueta Muñoz-Islas
    Juan Miguel Jiménez-Andrade
    BioMetals, 2022, 35 : 1033 - 1042