Effect of Bearing Type on Taper Material Loss in Hips From 1 Manufacturer

被引:7
|
作者
Hothi, Harry S. [1 ,2 ]
Eskelinen, Antti P. [3 ]
Henckel, Johann [1 ,2 ]
Kwon, Young-Min [4 ]
Blunn, Gordon W. [1 ,2 ]
Skinner, John A. [1 ,2 ]
Hart, Alister J. [1 ,2 ]
机构
[1] Univ Coll London, Inst Orthopaed & Musculoskeletal Sci, Stanmore, Middx, England
[2] Royal Natl Orthopaed Hosp, Stanmore, Middx, England
[3] Coxa Hosp Joint Replacement, Tampere, Finland
[4] Harvard Med Sch, Massachusetts Gen Hosp, Boston, MA USA
来源
JOURNAL OF ARTHROPLASTY | 2018年 / 33卷 / 05期
关键词
hip; taper; metal-on-polyethylene; corrosion; wear; ARTHROPLASTY; CORROSION; TRUNNIONOSIS; RETRIEVAL; IMPLANTS; JUNCTION;
D O I
10.1016/j.arth.2017.12.022
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Numerous studies have reported on clinical significant volumes of material loss and corrosion at the head-stem junction of metal-on-metal (MOM) hips; less is understood about metal-onpolyethylene (MOP) hips. We compared the effect of bearing type (MOM vs MOP) on taper material loss for a hip system of a single design. Methods: In this cohort study, we recruited retrieved MOM (n = 30) and MOP (n = 22) bearing hips that were consecutively received at our center. We prospectively collected associated clinical and imaging data. We measured the severity of corrosion and volumes of material loss at each head taper surface and used multivariate statistical analysis to investigate differences between the 2 bearing types. Results: The median rate of material loss for the MOM and MOP groups was 0.81 mm(3)/y (0.01-3.45) and 0.03 mm(3)/y (0-1.07), respectively (P <.001). Twenty-nine of 30 MOM hips were revised for adverse metal reactions, compared with 1 of 22 MOP hips. Conclusion: MOP hips lost significantly less material from their taper junctions than MOM hips. Our results can reassure patients with MOP Pinnacle hips that they are unlikely to experience clinically significant problems related to material loss from the taper junction. (C) 2018 Elsevier Inc. All rights reserved.
引用
收藏
页码:1588 / 1593
页数:6
相关论文
共 50 条
  • [1] Comparative study of material loss at the taper interface in retrieved metal-on-polyethylene and metal-on-metal femoral components from a single manufacturer
    Bills, Paul
    Racasan, Radu
    Bhattacharya, Saugatta
    Blunt, Liam
    Isaac, Graham
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2017, 231 (08) : 683 - 690
  • [2] Influence of stem type on material loss at the metal-on-metal pinnacle taper junction
    Hothi, Harry S.
    Whittaker, Robert K.
    Meswania, Jay M.
    Blunn, Gordon W.
    Skinner, John A.
    Hart, Alister J.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2015, 229 (01) : 91 - 97
  • [3] Volumetric material loss in metal-on-metal total hip arthroplasty: Bearing surface wear versus taper corrosion
    Hexter, A.
    Matthies, A.
    Bills, P.
    Skinner, J.
    Hart, A.
    BRITISH JOURNAL OF SURGERY, 2013, 100 : 42 - 42
  • [4] Method for Characterization of Material Loss from Modular Head-Stem Taper Surfaces of Hip Replacement Devices
    Racasan, Radu
    Bills, Paul
    Blunt, Liam
    Hart, Alister
    Skinner, John
    MODULARITY AND TAPERS IN TOTAL JOINT REPLACEMENT DEVICES, 2015, 1591 : 132 - 146
  • [5] Characterization of Material Loss from Femoral Stem Taper Surfaces through Development of a Responsive Morphological Filtering Technique
    Dransfield, Karl
    Racasan, Radu
    Blunt, Liam
    Bills, Paul
    BEYOND THE IMPLANT: RETRIEVAL ANALYSIS METHODS FOR IMPLANT SURVEILLANCE, 2018, 1606 : 173 - 190
  • [6] Quantifying material loss from the bearing surfaces of retrieved hip replacements: Method validation
    Bergiers, Sean
    Hothi, Harry
    Richards, Robin
    Dall'Ava, Lorenzo
    Henckel, Johann
    Hart, Alister
    TRIBOLOGY INTERNATIONAL, 2020, 142
  • [8] Quantification of material loss from the neck piece taper junctions of a bimodular primary hip prosthesis. A retrieval study from 27 failed Rejuvenate bimodular hip arthroplasties
    Buente, D.
    Huber, G.
    Bishop, N.
    Morlock, M.
    BONE & JOINT JOURNAL, 2015, 97B (10): : 1350 - 1357
  • [9] THE EFFECT OF FINENESS OF GRINDING OF A SAMPLE ON THE LOSS OF MATERIAL FROM NYLON BAGS INCUBATED IN THE RUMEN OF SHEEP
    KYLE, DJ
    HOVELL, FDD
    ANIMAL PRODUCTION, 1987, 44 : 496 - 496
  • [10] Effect of the reflected light from the surface of a material on measurement with reflecting type laser photoelasticity
    Shima, Yasufumi
    Yamashita, Daisuke
    Niitsu, Yasushi
    Nippon Kikai Gakkai Ronbunshu, A Hen/Transactions of the Japan Society of Mechanical Engineers, Part A, 2003, 69 (02): : 338 - 343