Use of Dried Plasma Spots for the Quantification of Iothalamate in Clinical Studies

被引:17
作者
Hagan, Andrew S. [1 ,2 ]
Jones, David R. [3 ]
Agarwal, Rajiv [1 ,2 ]
机构
[1] Indiana Univ Sch Med, Indianapolis, IN USA
[2] Richard L Roudebush Vet Adm Med Ctr, Indianapolis, IN 46202 USA
[3] Indiana Univ Sch Med, Dept Med, Div Clin Pharmacol, Indianapolis, IN USA
来源
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY | 2013年 / 8卷 / 06期
基金
美国国家卫生研究院;
关键词
GLOMERULAR-FILTRATION-RATE; LIQUID-CHROMATOGRAPHY; FILTER-PAPER; GFR; CHILDREN; SAMPLES; INULIN;
D O I
10.2215/CJN.10471012
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background and objectives Although iothalamate clearances have been widely used to measure GFR, the need for transportation of plasma samples under refrigerated conditions obviates its use in resource-poor situations. Spots of blood or plasma dried on filter paper may provide a solution. Design, setting, participants, & measurements Using a validated HPLC technique, iothalamate in dried blood spots of different hematocrits was measured. GFR was measured over 5 hours in 10 subjects with CKD using dried plasma spots and standard methods. Results Lower hematocrit produced greater area of blood spreading and lowered the recovery of iothalamate from dried blood spots. However, the relationship between iothalamate concentrations in dried plasma spots and plasma showed a regression slope of 0.95 (95% confidence interval=0.92-0.98, P<0.001). Bland-Altman plot of paired sample points (n=116) showed a bias of 4 mu g/ml and limits of agreement of -38 to +30 mu g/ml. The relationship between GFRs using dried plasma spots and plasma methods also showed an excellent relationship (slope of 0.95, 95% confidence interval=0.82-1.17). Bland Altman plot of paired GFRs showed a bias of 2 ml/min, with limits of agreement of -6 to +10 ml/min. Precision was generally between 5% and 10%, and accuracy was within 5%. Conclusions Although dried blood spots are unsuitable for studies among those patients with very low hematocrit, dried plasma spots correct for this limitation, and this small pilot study shows that it is a reasonably reliable method for quantifying iothalamate and subsequently, determining GFR.
引用
收藏
页码:909 / 914
页数:6
相关论文
共 16 条
[2]   Liquid chromatography for iothalamate in biological samples [J].
Agarwal, R ;
Vasavada, N ;
Chase, SD .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 785 (02) :345-352
[3]   Assessment of Iothalamate Plasma Clearance: Duration of Study Affects Quality of GFR [J].
Agarwal, Rajiv ;
Bills, Jennifer E. ;
Yigazu, Paulos M. ;
Abraham, Terri ;
Gizaw, Andinet B. ;
Light, Robert P. ;
Bekele, Dagim. M. ;
Tegegne, Getachew G. .
CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2009, 4 (01) :77-85
[4]   Comparison of iothalamate clearance methods for measuring GFR [J].
Dowling, TC ;
Frye, RF ;
Fraley, DS ;
Matzke, GR .
PHARMACOTHERAPY, 1999, 19 (08) :943-950
[5]   Estimating Equations for Glomerular Filtration Rate in the Era of Creatinine Standardization A Systematic Review [J].
Earley, Amy ;
Miskulin, Dana ;
Lamb, Edmund J. ;
Levey, Andrew S. ;
Uhlig, Katrin .
ANNALS OF INTERNAL MEDICINE, 2012, 156 (11) :785-+
[6]   GLOMERULAR-FILTRATION RATE MEASUREMENT BY SINGLE-SHOT INJECTION OF INULIN [J].
FLORIJN, KW ;
BARENDREGT, JNM ;
LENTJES, EGWM ;
VANDAM, W ;
PRODJOSUDJADI, W ;
VANSAASE, JLCM ;
VANES, LA ;
CHANG, PC .
KIDNEY INTERNATIONAL, 1994, 46 (01) :252-259
[7]  
GUTHRIE R, 1963, PEDIATRICS, V32, P338
[8]  
Knudsen R, 2012, CDC GUIDELINES SHIPM
[9]   Dried blood spot sampling in combination with LC-MS/MS for quantitative analysis of small molecules [J].
Li, Wenkui ;
Tse, Francis L. S. .
BIOMEDICAL CHROMATOGRAPHY, 2010, 24 (01) :49-65
[10]   Use of filter paper for the collection and analysis of human whole blood specimens [J].
Mei, JV ;
Alexander, JR ;
Adam, BW ;
Hannon, WH .
JOURNAL OF NUTRITION, 2001, 131 (05) :1631S-1636S