Biomechanical Model-Based Development of an Active Occupational Upper-Limb Exoskeleton to Support Healthcare Workers in the Surgery Waiting Room

被引:42
作者
Troester, Mark [1 ]
Wagner, David [1 ]
Mueller-Graf, Felix [1 ]
Maufroy, Christophe [1 ]
Schneider, Urs [1 ,2 ]
Bauernhansl, Thomas [1 ,2 ]
机构
[1] Fraunhofer Inst Mfg Engn & Automat IPA, Nobelstr 12, D-70569 Stuttgart, Germany
[2] Univ Stuttgart, Inst Ind Mfg & Management IFF, Allmandring 35, D-70569 Stuttgart, Germany
关键词
healthcare; ergonomics; manual work; exoskeleton; musculoskeletal modeling; OPTIMIZATION; DESIGN;
D O I
10.3390/ijerph17145140
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Occupational ergonomics in healthcare is an increasing challenge we have to handle in the near future. Physical assistive systems, so-called exoskeletons, are promising solutions to prevent work-related musculoskeletal disorders (WMSDs). Manual handling like pushing, pulling, holding and lifting during healthcare activities require practical and biomechanical effective assistive devices. In this article, a musculoskeletal-model-based development of an assistive exoskeleton is described for manual patient transfer in the surgery waiting room. For that purpose, kinematic data collected with an experimental set-up reproducing real patient transfer conditions are first used to define the kinetic boundary conditions for the model-based development approach. Model-based analysis reveals significant relief potential in the lower back and shoulder area of the musculoskeletal apparatus. This is corroborated by subjective feedback collected during measurements with real surgery assistants. A shoulder-arm exoskeleton design is then proposed, optimized and evaluated within the same simulation framework. The presented results illustrate the potential for the proposed design to reduce significantly joint compressions and muscle activities in the shoulder complex in the considered patient transfer scenarios.
引用
收藏
页码:1 / 16
页数:16
相关论文
共 24 条
[1]   In vivo glenohumeral contact forces -: Measurements in the first patient 7 months postoperatively [J].
Bergmann, G. ;
Graichen, F. ;
Bender, A. ;
Kaab, M. ;
Rohlmann, A. ;
Westerhoff, P. .
JOURNAL OF BIOMECHANICS, 2007, 40 (10) :2139-2149
[2]  
Brenscheidt S., 2020, ARBEITSWELT WANDEL Z, DOI https://doi.org/10.21934/baua:praxis20200131
[3]   JackEx: the new digital manufacturing resource for optimization of Exoskeleton-based factory environments [J].
Constantinescu, Carmen ;
Muresan, Paul-Cristian ;
Simon, Gabriel-Marian .
26TH CIRP DESIGN CONFERENCE, 2016, 50 :508-511
[4]  
Ellapen T., 2014, Journal Of Ergonomics, VS4, P1, DOI [10.4172/2165-7556.S4-003, 10.4172/2165-7556.s4-003, DOI 10.4172/2165-7556.S4-003]
[5]   Developments in hardware systems of active upper-limb exoskeleton robots: A review [J].
Gopura, R. A. R. C. ;
Bandara, D. S. V. ;
Kiguchi, Kazuo ;
Mann, G. K. I. .
ROBOTICS AND AUTONOMOUS SYSTEMS, 2016, 75 :203-220
[6]  
Inose Hiroki, 2017, 2017 IEEE International Conference on Robotics and Automation (ICRA), P6014, DOI 10.1109/ICRA.2017.7989711
[7]   Development and simulation of a passive upper extremity orthosis for amyoplasia [J].
Jensen, Erik F. ;
Raunsbaek, Joakim ;
Lund, Jan N. ;
Rahman, Tariq ;
Rasmussen, John ;
Castro, Miguel N. .
JOURNAL OF REHABILITATION AND ASSISTIVE TECHNOLOGIES ENGINEERING, 2018, 5
[8]  
Konig A.M., 2019, P INT JOINT C OCC HL
[9]   Solving the surgeon ergonomic crisis with surgical exosuit [J].
Liu, Shanglei ;
Hemming, Daniel ;
Luo, Ran B. ;
Reynolds, Jessica ;
Delong, Jonathan C. ;
Sandler, Bryan J. ;
Jacobsen, Garth R. ;
Horgan, Santiago .
SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2018, 32 (01) :236-244
[10]  
Luttmann A., 2003, PROTECTING WORKERSPR, V5