Reconstruction of facial morphology from laser scanned data.: Part I:: reliability of the technique

被引:28
作者
Ramieri, G. A.
Spada, M. C.
Nasi, A.
Tavolaccini, A.
Vezzetti, E.
Tornincasa, S.
Bianchi, S. D.
Verze, L.
机构
[1] Univ Turin, Dept Maxillofacial Surg, Turin, Italy
[2] Politecn Torino, Dept Prod Syst, Turin, Italy
[3] Univ Turin, Dept Radiol, Turin, Italy
[4] Univ Turin, Dept Anat, Turin, Italy
关键词
three-dimensional imaging; anthropometry; face; validation studies;
D O I
10.1259/dmfr/43516583
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of this study was to evaluate the effects of scanning parameters on the precision of the data acquired using a facial laser scanner and to assess the reliability of automatic model recording in humans. Methods: Data were acquired using a laser scanner (Cyberware 3030RGB); analysis and measurements were performed with Rapid Form 2004 software. A mannequin and six volunteers were scanned to investigate the effects of environmental conditions, positioning, head orientation, and software procedures. Precision and accuracy of the data were evaluated comparing six linear measures calculated on scanned data with those obtained directly. Two sessions with different head inclination were performed. The reliability of repeated scans was also assessed measuring the distance between the surfaces reconstructed from two separate scans of the same subject, at 12 anatomical points, in 5 subjects, during two sessions using a different head inclination. Differences were analysed using paired t-tests or analysis of variance (ANOVA). Results: The accuracy of scanning was +/- 0.65 mm. The development of a specific protocol resulted in a mean scanning error of 1-1.2 mm and a recording error of 0.3-0.4 mm on repeated scans of human subjects. Conclusions: This study indicates that scanning of the human face may be hampered by errors and artefacts, mainly due to movements. While the effect of trembling and involuntary movements during the exam may be minimized using faster scanning devices, comparative observation over time may be affected by unreal differences due to the uncertainty of facial expression. The overall error is, however, in the range useful for most clinical studies.
引用
收藏
页码:158 / 164
页数:7
相关论文
共 20 条
[1]  
[Anonymous], CYB COL 3D DIG PROD
[2]   EVALUATION OF THE LASER SCANNER AS A SURFACE MEASURING TOOL AND ITS ACCURACY COMPARED WITH DIRECT FACIAL ANTHROPOMETRIC MEASUREMENTS [J].
AUNG, SC ;
NGIM, RCK ;
LEE, ST .
BRITISH JOURNAL OF PLASTIC SURGERY, 1995, 48 (08) :551-558
[3]   Three-dimensional facial anthropometry using a laser surface scanner: Validation of the technique [J].
Bush, K ;
Antonyshyn, O .
PLASTIC AND RECONSTRUCTIVE SURGERY, 1996, 98 (02) :226-235
[4]   Three-dimensional computed tomography landmark measurement in craniofacial surgical planning: Experimental validation in vitro [J].
Cavalcanti, MGP ;
Haller, JW ;
Vannier, MW .
JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1999, 57 (06) :690-694
[5]   Craniofacial applications of three-dimensional laser surface scanning [J].
Da Silveira, AC ;
Daw, JL ;
Kusnoto, B ;
Evans, C ;
Cohen, M .
JOURNAL OF CRANIOFACIAL SURGERY, 2003, 14 (04) :449-456
[6]   Soft tissue facial anthropometry in Down syndrome subjects [J].
Ferrario, VF ;
Dellavia, C ;
Zanotti, G ;
Sforza, C .
JOURNAL OF CRANIOFACIAL SURGERY, 2004, 15 (03) :528-532
[7]   Facial three-dimensional morphometry [J].
Ferrario, VF ;
Sforza, C ;
Poggio, CE ;
Serrao, G .
AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 1996, 109 (01) :86-93
[8]   Novel methods for quantifying soft tissue changes after orthognathic surgery [J].
Guest, E ;
Berry, E ;
Morris, D .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 30 (06) :484-489
[9]   Use of hand-held laser scanning in the assessment of facial swelling: a preliminary study [J].
Harrison, JA ;
Nixon, MA ;
Fright, WR ;
Snape, L .
BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2004, 42 (01) :8-17
[10]   3D laser surface scanning and geometric morphometric analysis of craniofacial shape as in index of cerebro-craniofacial morphogenesis: Initial application to sexual dimorphism [J].
Hennessy, RJ ;
Kinsella, A ;
Waddington, JL .
BIOLOGICAL PSYCHIATRY, 2002, 51 (06) :507-514