The Reverse-Brayton cycle has been used for aircraft cabin cooling for many decades. However, air-cycle cooling hasn't been popular in the automotive field yet. This study demonstrates that air-cycle technology can provide sufficient cooling for certain applications. The primary focus is a novel forced induction engine control system, where compressor bleed is used both to provide engine boost control and air-conditioning. The bleed-air drives an air-cycle machine (ACM) consisting of typical automotive components: a turbocharger, heat exchanger, and ducting. The components of an ACM system are lightweight and compact compared to those of a typical vapor compression system; both qualities are critical in high performance applications, where such a system seems to make most sense. The ACM was tested first on a test stand and then directly on an engine, in a bootstrap-cycle configuration. The turbocharged test engine's intake manifold pressure was controlled by bleeding air from the outlet of the engine's intercooler and feeding the ACM compressor inlet. Once the compressed air was supplied to the ACM it was further compressed by the ACM, cooled by the secondary intercooler, and expanded through the ACM turbine. The engine's turbocharger was resized to compensate for the increased air flow during ACM operation. The results show that a dry-air-rated (DAR) coefficient of performance (COP) of 0.73 and a DAR cooling capacity of 1.5 tons are possible on a test stand, and a DAR COP of 0.56 and a DAR cooling capacity of 0.72 tons are possible on-engine. The data available from the on-engine testing was limited to lower ACM pressure ratios due to a bearing failure before full testing was complete; performance would likely increase with higher inlet pressures, as shown by the compressed air test stand results. The test results strongly suggest that continued development and in-vehicle testing will provide adequate air-conditioning and engine performance, using only the most benign and environmentally friendly working fluid: air.
引用
收藏
页码:833 / 842
页数:10
相关论文
共 35 条
  • [21] A control-oriented hybrid model for a direct expansion air conditioning system
    Xu, Xiangguo
    Huang, Zhiyuan
    Wang, Xiaofei
    Zhong, Ziwen
    Zhang, Xiaobo
    ENERGY AND BUILDINGS, 2017, 155 : 76 - 87
  • [22] Life Cycle Comparison of the Environmental and Economic Performance of an Informal Low-Capacity Passenger Transport System
    Kalifa, Muhammad
    Ozdemir, Alp
    Banar, Mufide
    TRANSPORTATION RESEARCH RECORD, 2024, 2678 (09) : 1 - 17
  • [23] Development of a superheat controller for mitigating hunting in a direct expansion air conditioning system
    Xia, Yudong
    Ding, Qiang
    Jiang, Zhoushu
    Deng, Shiming
    Song, Mengjie
    INNOVATIVE SOLUTIONS FOR ENERGY TRANSITIONS, 2019, 158 : 2085 - 2091
  • [24] Performance simulation of CO2 transcritical cooling system with mechanical subcooling cycle for automobile air conditioning
    Na, Sun-Ik
    Kim, Minsung
    Kim, Min Soo
    JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2022, 36 (09) : 4797 - 4807
  • [25] Modeling and optimal control of an energy-efficient hybrid solar air conditioning system
    Ha, Q. P.
    Vakiloroaya, V.
    AUTOMATION IN CONSTRUCTION, 2015, 49 : 262 - 270
  • [26] A control-oriented semi-physical model for a direct expansion air conditioning system
    Xu Xiangguo
    Deng Shiming
    Han Xiaohong
    Zhang Xuejun
    BUILDING SERVICES ENGINEERING RESEARCH & TECHNOLOGY, 2014, 35 (06) : 585 - 599
  • [27] Thermo-economic and environmental evaluation of a novel SOFC based trigeneration system using organic Rankine cycle and cascaded vapor compression-absorption refrigeration system
    Khan, Yunis
    Singh, Pawan Kumar
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2025, 57
  • [28] Assessing the environmental performance of optimized commercial refrigerators with alternative refrigerants and remote monitoring system: A cradle-to-grave life cycle assessment
    Temporim, Ramoon Barros Lovate
    Di Giuseppe, Alessia
    Landi, Fabiana Frota de Albuquerque
    Nicolini, Andrea
    HELIYON, 2024, 10 (07)
  • [29] Generic simulation model of multi-evaporator variable refrigerant flow air conditioning system for control analysis
    Zhu, Yonghua
    Jin, Xinqiao
    Du, Zhimin
    Fan, Bo
    Fu, Sijie
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2013, 36 (06): : 1602 - 1615
  • [30] A DDC-based capacity controller of a direct expansion (DX) air conditioning (A/C) unit for simultaneous indoor air temperature and humidity control - Part II: Further development of the controller to improve control sensitivity
    Li, Zheng
    Deng, Shiming
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2007, 30 (01): : 124 - 133