Open-wedge high tibial osteotomy: comparison between manual and computer-assisted techniques

被引:64
作者
Iorio, R. [1 ,2 ]
Pagnottelli, M. [1 ,2 ]
Vadala, A. [1 ,2 ]
Giannetti, S. [1 ,2 ]
Di Sette, P. [1 ,2 ]
Papandrea, P. [1 ,2 ]
Conteduca, F. [1 ,2 ]
Ferretti, A. [1 ,2 ]
机构
[1] Univ Roma La Sapienza, S Andrea Hosp, Orthopaed Unit, I-00123 Rome, RM, Italy
[2] Univ Roma La Sapienza, S Andrea Hosp, Kirk Kilgour Sports Injury Ctr, I-00123 Rome, RM, Italy
关键词
Open-wedge high tibial osteotomy; mFTA; Tibial slope; Computer-assisted technique; TERM-FOLLOW-UP; LONG-TERM; VARUS GONARTHROSIS; VALGUS OSTEOTOMY; PATELLAR HEIGHT; SAGITTAL PLANE; CONVENTIONAL TECHNIQUE; EXTERNAL FIXATOR; AXIAL ALIGNMENT; KNEE;
D O I
10.1007/s00167-011-1785-5
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of our study was to compare clinical and radiological results of two groups of patients treated for medial compartment osteoarthritis of the knee with either conventional or computer-assisted open-wedge high tibial osteotomy (HTO). Goals of surgical treatment were a correction of the mechanical axis between 2A degrees and 6A degrees of valgus and a modification of posterior tibial slope between -2A degrees and +2A degrees. Twenty-four patients (27 knees) affected by varus knee deformity and operated with HTO were prospectively followed-up. They were randomly divided in two groups, A (11 patients, conventional treatment) and B (13 patients, navigated treatment). The American Knee Society Score and the Modified Cincinnati Rating System Questionnaire were used for clinical assessment. All patients were radiologically evaluated with a comparative lower limb weight-bearing digital radiograph, a standard digital anteroposterior, a latero-lateral radiograph of the knee, and a Rosenberg view. Patients were followed-up at a mean of 39 months. Clinical evaluation showed no statistical difference (n.s.) between the two groups. Radiological results showed an 86% reproducibility in achieving a mechanical axis of 182A degrees-186A degrees in group B compared to a 23% in group A (p = 0.0392); furthermore, in group B, we achieved a modification of posterior tibial slope between -2A degrees and +2A degrees in 100% of patients, while in group A, this goal was achieved only in 24% of cases (p = 0.0021). High tibial osteotomy with navigator is more accurate and reproducible in the correction of the deformity compared to standard technique. Therapeutic study, Level II.
引用
收藏
页码:113 / 119
页数:7
相关论文
共 55 条
  • [1] Effect of high tibial flexion osteotomy on cartilage pressure and joint kinematics: a biomechanical study in human cadaveric knees - Winner of the AGA-DonJoy Award 2004
    Agneskirchner, JD
    Hurschler, C
    Stukenborg-Colsman, C
    Imhoff, AB
    Lobenhoffer, P
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2004, 124 (09) : 575 - 584
  • [2] Closed-wedge high tibial osteotomy using computer-assisted surgery compared to the conventional technique
    Bae, D. K.
    Song, S. J.
    Yoon, K. H.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (09): : 1164 - 1171
  • [3] High tibial osteotomy with a calibrated osteotomy guide, rigid internal fixation, and early motion - Long-term follow-up
    Billings, A
    Scott, DF
    Camargo, MP
    Hofmann, AA
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (01) : 70 - 79
  • [4] Patellar height and the inclination of the tibial plateau after high tibial osteotomy -: The open versus the closed-wedge technique
    Brouwer, RW
    Bierma-Zeinstra, SMA
    van Koeveringe, AJ
    Verhaar, JAN
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (09): : 1227 - 1232
  • [5] Tibial slope and patellar height after opening wedge high tibia osteotomy using autologous tricortical iliac bone graft
    Chae, Dong Ju
    Shetty, Gautarn M.
    Lee, Dong Bong
    Choi, Hyun Woo
    Han, Seung Beorn
    Nha, Kyung Wook
    [J]. KNEE, 2008, 15 (02) : 128 - 133
  • [6] Coventry M B, 1982, Acta Orthop Belg, V48, P139
  • [7] PROXIMAL TIBIAL OSTEOTOMY - A CRITICAL LONG-TERM STUDY OF 87 CASES
    COVENTRY, MB
    ILSTRUP, DM
    WALLRICHS, SL
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1993, 75A (02) : 196 - 201
  • [8] COVENTRY MB, 1979, ORTHOP CLIN N AM, V10, P191
  • [9] Tibial slope changes following dome-type high tibial osteotomy
    Çullu, E
    Aydogdu, S
    Alparslan, B
    Sur, H
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2005, 13 (01) : 38 - 43
  • [10] A 12-28-year followup study of closing wedge high tibial osteotomy
    Flecher, Xavier
    Parratte, Sebastien
    Aubaniac, Jean-Manuel
    Argenson, Jean-Noel A.
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2006, (452) : 91 - 96