Enhancing the Reliability of Chiller Control Using Fused Measurement of Building Cooling Load

被引:19
作者
Huang, Gongsheng [1 ]
Wang, Shengwei [1 ]
Sun, Yongjun [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Kowloon, Hong Kong, Peoples R China
来源
HVAC&R RESEARCH | 2008年 / 14卷 / 06期
关键词
D O I
10.1080/10789669.2008.10391048
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper presents a general framework of utilizing a fused measurement of the building instantaneous cooling load to improve the reliability of the chiller sequencing control in building automation systems. The fused measurement is obtained by combining the complementary advantages of two different approaches to measuring the building cooling load. One approach is the direct measurement, which calculates the building cooling load directly, using the differential water temperature and water flow rate measurements. The other is the indirect measurement, which calculates building cooling load based on chiller models using the instantaneous chiller electrical power input, etc. The combination strategy is tested using the field data collected from the central plant of the air-conditioning system in a high-rise building in Hong Kong. The confidence degree associated with the fused measurement is systematically evaluated. Periodic update of the fusion algorithm parameters is also developed to improve the performance of the fusion strategy and the chiller sequencing control.
引用
收藏
页码:941 / 958
页数:18
相关论文
共 23 条
  • [1] Combined bias and outlier identification in dynamic data reconciliation
    Abu-el-zeet, ZH
    Becerra, VM
    Roberts, PD
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 2002, 26 (06) : 921 - 935
  • [2] [Anonymous], ENG MAN AUT CONTR CO
  • [3] [Anonymous], ASHRAE T
  • [4] Brown M, 1994, NEUROFUZZY ADAPTIVE
  • [5] Optimal chiller sequencing by branch and boun method for saving energy
    Chang, YC
    Lin, FA
    Lin, CH
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2005, 46 (13-14) : 2158 - 2172
  • [6] Optimal chiller loading by genetic algorithm for reducing energy consumption
    Chang, YC
    Lin, JK
    Chuang, MH
    [J]. ENERGY AND BUILDINGS, 2005, 37 (02) : 147 - 155
  • [7] A strategy for simultaneous dynamic data reconciliation and outlier detection
    Chen, J
    Romagnoli, JA
    [J]. COMPUTERS & CHEMICAL ENGINEERING, 1998, 22 (4-5) : 559 - 562
  • [8] The fusion of redundant SEVA measurements
    Duta, M
    Henry, M
    [J]. IEEE TRANSACTIONS ON CONTROL SYSTEMS TECHNOLOGY, 2005, 13 (02) : 173 - 184
  • [9] A review of data fusion models and architectures: Towards engineering guidelines
    Esteban, J
    Starr, A
    Willetts, R
    Hannah, P
    Bryanston-Cross, P
    [J]. NEURAL COMPUTING & APPLICATIONS, 2005, 14 (04) : 273 - 281
  • [10] How varying condenser coolant flow rate affects chiller performance: thermodynamic modeling and experimental confirmation
    Gordon, JM
    Ng, KC
    Chua, HT
    Lim, CK
    [J]. APPLIED THERMAL ENGINEERING, 2000, 20 (13) : 1149 - 1159