Effect of Finishing and Polishing on Roughness and Gloss of Lithium Disilicate and Lithium Silicate Zirconia Reinforced Glass Ceramic for CAD/CAM Systems
被引:73
|
作者:
论文数: 引用数:
h-index:
机构:
Vichi, A.
[1
,2
,3
]
论文数: 引用数:
h-index:
机构:
Fonzar, R. Fabian
[1
]
论文数: 引用数:
h-index:
机构:
Goracci, C.
[1
]
论文数: 引用数:
h-index:
机构:
Carrabba, M.
[1
]
Ferrari, M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ Siena, Dept Med Biotechnol, Siena, Italy
Univ Leeds, Dept Restorat Dent, Leeds, W Yorkshire, EnglandUniv Siena, Dept Med Biotechnol, Siena, Italy
Ferrari, M.
[1
,4
]
机构:
[1] Univ Siena, Dept Med Biotechnol, Siena, Italy
[2] LUdeS HEI Fdn, Fac Med Sci, Lugano, Switzerland
[3] LUdeS HEI Fdn, Fac Med Sci, La Valletta, Malta
[4] Univ Leeds, Dept Restorat Dent, Leeds, W Yorkshire, England
Objective: To assess the efficacy of dedicated finishing/polishing systems on roughness and gloss of VITA Suprinity and IPS e.max CAD. Method: A total of 24 blocks of Suprinity and 24 of e.max were cut into a wedge shape using an InLab MC-XL milling unit. After crystallization, the 24 Suprinity wedges were divided into four subgroups: group A. 1: Suprinity Polishing Set Clinical used for 30 seconds and group A. 2: for 60 seconds; group A. 3: VITA Akzent Plus Paste; and group A. 4: spray. The 24 e.max wedges (group B) were divided into four subgroups according to the finishing procedure: group B. 1: Optrafine Ceramic Polishing System for 30 seconds and group B. 2: for 60 seconds; group B. 3: IPS e.max CAD Crystall/Glaze paste; and group B. 4: spray. After finishing/polishing, gloss was assessed with a gloss-meter and roughness evaluated with a profilometer. Results were analyzed by applying a two-way analysis of variance for gloss and another for roughness (alpha=0.05). One specimen per each subgroup was observed with a scanning electron microscope. Results: For roughness, materials and surface were significant factors (p < 0.001). Suprinity exhibited significantly lower roughness than e.max. Also the Material-Surface Treatment interaction was statistically significant (p=0.026). For gloss, both material and surface treatment were significant factors (p < 0.001). VITA Suprinity showed significantly higher gloss than e.max. Also the Material-Surface Treatment interaction was statistically significant (p < 0 .001). Conclusions: Manual finishing/polishing for 60 seconds and glazing paste are the most effective procedures in lowering the roughness of CAD/CAM silica-based glass ceramics. Manual finishing/polishing for 60 seconds allows milled silica-based glass ceramics to yield a higher gloss. VITA Suprinity displayed higher polishability than IPS e.max CAD.
机构:
Yonsei Univ, Dept Prosthodont, Coll Dent, Seoul 120749, South KoreaYonsei Univ, Dept Prosthodont, Coll Dent, Seoul 120749, South Korea
Kim, Jee Hwan
Lee, Su-Jeong
论文数: 0引用数: 0
h-index: 0
机构:
Korea Univ, Grad Sch Clin Dent, Dept Esthet Restorat Dent, Seoul 136713, South KoreaYonsei Univ, Dept Prosthodont, Coll Dent, Seoul 120749, South Korea
Lee, Su-Jeong
Park, Jun Sub
论文数: 0引用数: 0
h-index: 0
机构:
Korea Univ, Grad Sch Clin Dent, Dept Esthet Restorat Dent, Seoul 136713, South KoreaYonsei Univ, Dept Prosthodont, Coll Dent, Seoul 120749, South Korea
Park, Jun Sub
Ryu, Jae Jun
论文数: 0引用数: 0
h-index: 0
机构:
Korea Univ, Grad Sch Clin Dent, Dept Esthet Restorat Dent, Seoul 136713, South KoreaYonsei Univ, Dept Prosthodont, Coll Dent, Seoul 120749, South Korea
机构:Gangneung Wonju Natl Univ, Dept Prosthodont, Kangnung, South Korea
Lee, Ye-Jin
Huh, Yoon-Hyuk
论文数: 0引用数: 0
h-index: 0
机构:Gangneung Wonju Natl Univ, Dept Prosthodont, Kangnung, South Korea
Huh, Yoon-Hyuk
Ko, Kyung-Ho
论文数: 0引用数: 0
h-index: 0
机构:Gangneung Wonju Natl Univ, Dept Prosthodont, Kangnung, South Korea
Ko, Kyung-Ho
Park, Chan-Jin
论文数: 0引用数: 0
h-index: 0
机构:Gangneung Wonju Natl Univ, Dept Prosthodont, Kangnung, South Korea
Park, Chan-Jin
Cho, Lee-Ra
论文数: 0引用数: 0
h-index: 0
机构:
Gangneung Wonju Natl Univ, Dept Prosthodont, Kangnung, South Korea
Gangneung Wonju Natl Univ, Res Inst Oral Sci, Coll Den, Kangnung, South KoreaGangneung Wonju Natl Univ, Dept Prosthodont, Kangnung, South Korea
机构:
King Abdulaziz Univ, Fac Dent, Oral & Maxillofacial Prosthodont Dept, Jeddah, Saudi Arabia
King Abdulaziz Univ, Fac Dent, Dept Oral & Maxillofacial Prosthodont, POB 80200, Jeddah 21589, Saudi ArabiaKing Abdulaziz Univ, Fac Dent, Oral & Maxillofacial Prosthodont Dept, Jeddah, Saudi Arabia
Alshali, Ruwaida Z.
AlQahtani, Mohammed A.
论文数: 0引用数: 0
h-index: 0
机构:
King Saud Univ, Coll Dent, Prosthet Dent Sci, Riyadh, Saudi ArabiaKing Abdulaziz Univ, Fac Dent, Oral & Maxillofacial Prosthodont Dept, Jeddah, Saudi Arabia
AlQahtani, Mohammed A.
Bukhary, Dalea M.
论文数: 0引用数: 0
h-index: 0
机构:
King Abdulaziz Univ, Fac Dent, Oral & Maxillofacial Prosthodont Dept, Jeddah, Saudi ArabiaKing Abdulaziz Univ, Fac Dent, Oral & Maxillofacial Prosthodont Dept, Jeddah, Saudi Arabia
Bukhary, Dalea M.
Alzahrani, Mlak A.
论文数: 0引用数: 0
h-index: 0
机构:
King Abdulaziz Univ, Fac Dent, Jeddah, Saudi ArabiaKing Abdulaziz Univ, Fac Dent, Oral & Maxillofacial Prosthodont Dept, Jeddah, Saudi Arabia
Alzahrani, Mlak A.
Alsoraihi, Shatha S.
论文数: 0引用数: 0
h-index: 0
机构:
Minist Hlth, Mecca, Makkah, Saudi ArabiaKing Abdulaziz Univ, Fac Dent, Oral & Maxillofacial Prosthodont Dept, Jeddah, Saudi Arabia
Alsoraihi, Shatha S.
Alqahtani, Majed A.
论文数: 0引用数: 0
h-index: 0
机构:
Minist Hlth, Abha, Aseer, Saudi ArabiaKing Abdulaziz Univ, Fac Dent, Oral & Maxillofacial Prosthodont Dept, Jeddah, Saudi Arabia