共 50 条
Effect of Finishing and Polishing on Roughness and Gloss of Lithium Disilicate and Lithium Silicate Zirconia Reinforced Glass Ceramic for CAD/CAM Systems
被引:73
|作者:
Vichi, A.
[1
,2
,3
]
Fonzar, R. Fabian
[1
]
Goracci, C.
[1
]
Carrabba, M.
[1
]
Ferrari, M.
[1
,4
]
机构:
[1] Univ Siena, Dept Med Biotechnol, Siena, Italy
[2] LUdeS HEI Fdn, Fac Med Sci, Lugano, Switzerland
[3] LUdeS HEI Fdn, Fac Med Sci, La Valletta, Malta
[4] Univ Leeds, Dept Restorat Dent, Leeds, W Yorkshire, England
关键词:
SURFACE-ROUGHNESS;
FLEXURAL RESISTANCE;
DENTAL PORCELAIN;
IN-VIVO;
WEAR;
ENAMEL;
PERFORMANCE;
COMPOSITES;
STRENGTH;
TRANSLUCENCY;
D O I:
10.2341/16-381-L
中图分类号:
R78 [口腔科学];
学科分类号:
1003 ;
摘要:
Objective: To assess the efficacy of dedicated finishing/polishing systems on roughness and gloss of VITA Suprinity and IPS e.max CAD. Method: A total of 24 blocks of Suprinity and 24 of e.max were cut into a wedge shape using an InLab MC-XL milling unit. After crystallization, the 24 Suprinity wedges were divided into four subgroups: group A. 1: Suprinity Polishing Set Clinical used for 30 seconds and group A. 2: for 60 seconds; group A. 3: VITA Akzent Plus Paste; and group A. 4: spray. The 24 e.max wedges (group B) were divided into four subgroups according to the finishing procedure: group B. 1: Optrafine Ceramic Polishing System for 30 seconds and group B. 2: for 60 seconds; group B. 3: IPS e.max CAD Crystall/Glaze paste; and group B. 4: spray. After finishing/polishing, gloss was assessed with a gloss-meter and roughness evaluated with a profilometer. Results were analyzed by applying a two-way analysis of variance for gloss and another for roughness (alpha=0.05). One specimen per each subgroup was observed with a scanning electron microscope. Results: For roughness, materials and surface were significant factors (p < 0.001). Suprinity exhibited significantly lower roughness than e.max. Also the Material-Surface Treatment interaction was statistically significant (p=0.026). For gloss, both material and surface treatment were significant factors (p < 0.001). VITA Suprinity showed significantly higher gloss than e.max. Also the Material-Surface Treatment interaction was statistically significant (p < 0 .001). Conclusions: Manual finishing/polishing for 60 seconds and glazing paste are the most effective procedures in lowering the roughness of CAD/CAM silica-based glass ceramics. Manual finishing/polishing for 60 seconds allows milled silica-based glass ceramics to yield a higher gloss. VITA Suprinity displayed higher polishability than IPS e.max CAD.
引用
收藏
页码:90 / 100
页数:11
相关论文