Electron scattering cross section measurements in a variable pressure scanning electron microscope

被引:5
|
作者
Wight, Scott A. [1 ]
Konicek, Andrew R. [1 ]
机构
[1] NIST, Surface & Microanal Sci Div, Gaithersburg, MD 20899 USA
关键词
Scattering cross section; Stagnation gas thickness; Beam gas path length; Electron scattering; Environmental scanning electron microscope; ESEM; VPSEM; X-RAY-MICROANALYSIS; GAS PATH-LENGTH; BEAM SCATTERING; SEM;
D O I
10.1016/j.micron.2012.04.003
中图分类号
TH742 [显微镜];
学科分类号
摘要
Scattering of the incident electron beam in the variable pressure scanning electron microscope (VPSEM) affects the ability to perform quantitative chemical measurements. However, the manner in which the sum of the elastic and inelastic scattering cross sections varies as a function of gas type and accelerating voltage in the VPSEM is not well understood. A dual Faraday cup was constructed to measure the scattered fraction of the primary beam as a function of gas pressure, working distance, and accelerating voltage in air, water vapor, and argon environments. Experimentally measured values of the scattering cross section agree with previous experimental work, and agree within a factor of two with those values calculated carefully from theory. (C) 2012 Published by Elsevier Ltd.
引用
收藏
页码:985 / 991
页数:7
相关论文
共 50 条
  • [31] Contact detection for nanomanipulation in a scanning electron microscope
    Ru, Changhai
    To, Steve
    ULTRAMICROSCOPY, 2012, 118 : 61 - 66
  • [32] Investigation of scanning electron microscope overlay metrology
    Koike, T
    Ikeda, T
    Abe, H
    Komatsu, F
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1999, 38 (12B): : 7159 - 7163
  • [33] Autofocus on moving object in scanning electron microscope
    Kudryavtsev, Andrey V.
    Dembele, Sounkalo
    Piat, Nadine
    ULTRAMICROSCOPY, 2017, 182 : 216 - 225
  • [34] Testing meat tenderness using an in situ straining stage with variable pressure scanning electron microscopy
    James, Bryony
    Yang, Seo Won
    11TH INTERNATIONAL CONGRESS ON ENGINEERING AND FOOD (ICEF11), 2011, 1 : 258 - 266
  • [35] On the environmental scanning electron microscope for taxonomic purposes
    Valdecasas, AG
    Camacho, AI
    INVERTEBRATE BIOLOGY, 2005, 124 (01) : 66 - 73
  • [36] Low voltage and variable-pressure scanning electron microscopy of fractured composites
    de Oliveira Hein, Luis Rogerio
    de Campos, Kamila Amato
    Reis de Oliveira Caltabiano, Pietro Carelli
    MICRON, 2012, 43 (10) : 1039 - 1049
  • [37] Experimental evaluation of environmental scanning electron microscopes at high chamber pressure
    Fitzek, H.
    Schroettner, H.
    Wagner, J.
    Hofer, F.
    Rattenberger, J.
    JOURNAL OF MICROSCOPY, 2015, 260 (02) : 133 - 139
  • [38] Study on algorithm of automatic alignment compensation of electron gun in a scanning electron microscope
    Kim S.-J.
    Jang D.-Y.
    Jang, Dong-Young (dyjang@seoultech.ac.kr), 1600, Inderscience Publishers (13): : 362 - 370
  • [39] Electron impact scattering from pentane molecules and effect of isomerism on cross section
    Tomer, Himani
    Modak, Paresh
    Sinha, Nidhi
    Antony, Bobby
    CHEMICAL PHYSICS IMPACT, 2021, 3
  • [40] Transmission environmental scanning electron microscope with scintillation gaseous detection device
    Danilatos, Gerasimos
    Kollia, Mary
    Dracopoulos, Vassileios
    ULTRAMICROSCOPY, 2015, 150 : 44 - 53