Motion correction methods for MRS: experts' consensus recommendations

被引:37
作者
Andronesi, Ovidiu C. [1 ]
Bhattacharyya, Pallab K. [2 ]
Bogner, Wolfgang [3 ]
Choi, In-Young [4 ]
Hess, Aaron T. [5 ]
Lee, Phil [6 ]
Meintjes, Ernesta M. [7 ]
Tisdall, M. Dylan [8 ]
Zaitzev, Maxim [9 ,10 ]
van der Kouwe, Andre [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Dept Radiol, Athinoula A Martinos Ctr Biomed Imaging, Thirteenth St, Boston, MA 02129 USA
[2] Cleveland Clin, Imaging Inst, Cleveland, OH 44106 USA
[3] Med Univ Vienna, Dept Biomed Imaging & Image Guided Therapy, High Field MR Ctr, Vienna, Austria
[4] Univ Kansas, Med Ctr, Dept Neurol, Hoglund Biomed Imaging Ctr, Kansas City, KS 66103 USA
[5] Univ Oxford, Univ Oxford Ctr Clin Magnet Resonance Res, Div Cardiovasc Med, Oxford, England
[6] Univ Kansas, Med Ctr, Dept Radiol, Hoglund Biomed Imaging Ctr, Kansas City, KS 66103 USA
[7] Univ Cape Town, Div Biomed Engn, Dept Human Biol, Biomed Engn Res Ctr,Fac Hlth Sci, Cape Town, South Africa
[8] Univ Penn, Dept Radiol, Perelman Sch Med, Philadelphia, PA 19104 USA
[9] Univ Freiburg, Dept Radiol, Med Ctr, Med Phys, Freiburg, Germany
[10] Med Univ Vienna, High Field Magnet Resonance Ctr, Ctr Med Phys & Biomed Engn, Vienna, Austria
基金
奥地利科学基金会; 英国医学研究理事会; 新加坡国家研究基金会;
关键词
Metabolites-neurochemistry; motion correction; MRS; navigator; NMR probes; optical tracking; real time; shim correction; REAL-TIME MOTION; RESONANCE-SPECTROSCOPY; HUMAN BRAIN; WATER-SUPPRESSION; SPECTRAL QUALITY; VOLUMETRIC NAVIGATORS; PROTON SPECTROSCOPY; SIGNAL LOSS; FREQUENCY; ARTIFACTS;
D O I
10.1002/nbm.4364
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Long acquisition times due to intrinsically low signal-to-noise ratio and the need for highly homogeneousB(0)field make MRS particularly susceptible to motion or scanner instability compared with MRI. Motion-induced changes in both localization and shimming (ieB(0)homogeneity) degrade MRS data quality. To mitigate the effects of motion three approaches can be employed: (1) subject immobilization, (2) retrospective correction, and (3) prospective real-time correction using internal and/or external tracking methods. Prospective real-time correction methods can simultaneously update localization and theB(0)field to improve MRS data quality. While localization errors can be corrected with both internal (navigators) and external (optical camera, NMR probes) tracking methods, theB(0)field correction requires internal navigator methods to measure theB(0)field inside the imaged volume and the possibility to update the scanner shim hardware in real time. Internal and external tracking can rapidly update the MRS localization with submillimeter and subdegree precision, while scanner frequency and first-order shims of scanner hardware can be updated by internal methods every sequence repetition. These approaches are most well developed for neuroimaging, for which rigid transformation is primarily applicable. Real-time correction greatly improves the stability of MRS acquisition and quantification, as shown in clinical studies on subjects prone to motion, including children and patients with movement disorders, enabling robust measurement of metabolite signals including those with low concentrations, such as gamma-aminobutyric acid and glutathione. Thus, motion correction is recommended for MRS users and calls for tighter integration and wider availability of such methods by MR scanner manufacturers.
引用
收藏
页数:15
相关论文
共 50 条
[21]   Fast high-resolution prospective motion correction for single-voxel spectroscopy [J].
Adanyeguh, Isaac M. ;
Bikkamane Jayadev, Nutandev ;
Henry, Pierre-Gilles ;
Deelchand, Dinesh K. .
MAGNETIC RESONANCE IN MEDICINE, 2024, 91 (04) :1301-1313
[22]   Self-navigated prospective motion correction for 3D-EPI acquisition [J].
Bayih, Samuel Getaneh ;
Jankiewicz, Marcin ;
Alhamud, A. ;
van der Kouwe, Andre J. W. ;
Meintjes, Ernesta M. .
MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (01) :211-223
[23]   Advanced Motion Correction Methods in PET (Review Article) [J].
Rahmim, Arman .
IRANIAN JOURNAL OF NUCLEAR MEDICINE, 2005, 13 (02) :1-17
[24]   Comparison of nonlinear methods of motion correction in fMRI data [J].
Efitorov, Alexander ;
Orlov, Vyacheslav ;
Ushakov, Vadim ;
Shirokiy, Vladimir ;
Dolenko, Sergey .
POSTPROCEEDINGS OF THE 9TH ANNUAL INTERNATIONAL CONFERENCE ON BIOLOGICALLY INSPIRED COGNITIVE ARCHITECTURES (BICA 2018), 2018, 145 :188-192
[25]   Accuracy of motion correction methods for PET brain imaging [J].
Fulton, R ;
Tellmann, L ;
Pietrzyk, U ;
Winz, O ;
Stangier, I ;
Nickel, I ;
Schmid, A ;
Meikle, S ;
Herzog, H .
2004 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-7, 2004, :4226-4230
[26]   Head motion measurement and correction using FID navigators [J].
Wallace, Tess E. ;
Afacan, Onur ;
Waszak, Maryna ;
Kober, Tobias ;
Warfield, Simon K. .
MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (01) :258-274
[27]   Analysis and comparison of two methods for motion correction in PET imaging [J].
Polycarpou, I. ;
Tsoumpas, C. ;
Marsden, P. K. .
MEDICAL PHYSICS, 2012, 39 (10) :6474-6483
[28]   Reverse Retrospective Motion Correction [J].
Zahneisen, Benjamin ;
Keating, Brian ;
Singh, Aditya ;
Herbst, Michael ;
Ernst, Thomas .
MAGNETIC RESONANCE IN MEDICINE, 2016, 75 (06) :2341-2349
[29]   Motion correction in MRI of the brain [J].
Godenschweger, F. ;
Kaegebein, U. ;
Stucht, D. ;
Yarach, U. ;
Sciarra, A. ;
Yakupov, R. ;
Luesebrink, F. ;
Schulze, P. ;
Speck, O. .
PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (05) :R32-R56
[30]   Stop moving: MR motion correction as an opportunity for artificial intelligence [J].
Zhou, Zijian ;
Hu, Peng ;
Qi, Haikun .
MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024, 37 (03) :397-409