Multi-Material Decomposition using Low-Current X-Ray and a Photon-Counting CZT Detector

被引:0
作者
Kim, Sangtaek [1 ]
Hernandez, Andrew
Alhassen, Fares [1 ]
Pivovaroff, Michael [2 ]
Cho, Hyo-Min [3 ]
Gould, Robert G. [1 ]
Seo, Youngho [1 ]
机构
[1] Univ Calif San Francisco, Phys Res Lab, San Francisco, CA 94107 USA
[2] Lawrence Livermore Natl Lab, Livermore, CA 94550 USA
[3] Yonsei Univ, Wonju, South Korea
来源
2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC) | 2011年
基金
美国国家卫生研究院;
关键词
CT; DENSITY; SYSTEM;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We developed and evaluated an x-ray photon-counting imaging system using an energy-resolving cadmium zinc telluride (CZT) detector coupled with application specific integrated circuit (ASIC) readouts. This x-ray imaging system can be used to identify different materials inside the object. The CZT detector has a large active area (5x5 array of 25 CZT modules, each with 16x16 pixels, cover a total area of 200 mm x 200 mm), high stopping efficiency for x-ray photons (similar to 100 % at 60 keV and 5 mm thickness). We explored the performance of this system by applying different energy windows around the absorption edges of target materials, silver and indium, in order to distinguish one material from another. The photon-counting CZT-based x-ray imaging system was able to distinguish between the materials, demonstrating its capability as a radiation-spectroscopic decomposition system.
引用
收藏
页码:4735 / 4738
页数:4
相关论文
共 15 条
  • [1] Comparison of dual energy detector system performance
    Alvarez, RE
    Seibert, JA
    Thompson, SK
    [J]. MEDICAL PHYSICS, 2004, 31 (03) : 556 - 565
  • [2] An application specific integrated circuit and data acquisition system for digital X-ray imaging
    Beuville, E
    Cederstrom, B
    Danielsson, M
    Luo, L
    Nygren, D
    Oltman, E
    Vestlund, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1998, 406 (02) : 337 - 342
  • [3] Nanocrystal Core High-Density Lipoproteins: A Multimodality Contrast Agent Platform
    Cormode, David P.
    Skajaa, Torjus
    van Schooneveld, Matti M.
    Koole, Rolf
    Jarzyna, Peter
    Lobatto, Mark E.
    Calcagno, Claudia
    Barazza, Alessandra
    Gordon, Ronald E.
    Zanzonico, Pat
    Fisher, Edward A.
    Fayad, Zahi A.
    Mulder, Willem J. M.
    [J]. NANO LETTERS, 2008, 8 (11) : 3715 - 3723
  • [4] Atherosclerotic Plaque Composition: Analysis with Multicolor CT and Targeted Gold Nanoparticles
    Cormode, David P.
    Roessl, Ewald
    Thran, Axel
    Skajaa, Torjus
    Gordon, Ronald E.
    Schlomka, Jens-Peter
    Fuster, Valentin
    Fisher, Edward A.
    Mulder, Willem J. M.
    Proksa, Roland
    Fayad, Zahi A.
    [J]. RADIOLOGY, 2010, 256 (03) : 774 - 782
  • [5] Multienergy Photon-counting K-edge Imaging: Potential for Improved Luminal Depiction in Vascular Imaging
    Feuerlein, Sebastian
    Roessl, Ewald
    Proksa, Roland
    Martens, Gerhard
    Klass, Oliver
    Jeltsch, Martin
    Rasche, Volker
    Brambs, Hans-Juergen
    Hoffmann, Martin H. K.
    Schlomka, Jens-Peter
    [J]. RADIOLOGY, 2008, 249 (03) : 1010 - 1016
  • [6] GENERALIZED IMAGE COMBINATIONS IN DUAL KVP DIGITAL RADIOGRAPHY
    LEHMANN, LA
    ALVAREZ, RE
    MACOVSKI, A
    BRODY, WR
    PELC, NJ
    RIEDERER, SJ
    HALL, AL
    [J]. MEDICAL PHYSICS, 1981, 8 (05) : 659 - 667
  • [7] Targeted Gold Nanoparticles Enable Molecular CT Imaging of Cancer
    Popovtzer, Rachela
    Agrawal, Ashish
    Kotov, Nicholas A.
    Popovtzer, Aron
    Balter, James
    Carey, Thomas. E.
    Kopelman, Raoul
    [J]. NANO LETTERS, 2008, 8 (12) : 4593 - 4596
  • [8] Improved dual-energy material discrimination for dual-source CT by means of additional spectral filtration
    Primak, A. N.
    Ramirez Giraldo, J. C.
    Liu, X.
    Yu, L.
    McCollough, C. H.
    [J]. MEDICAL PHYSICS, 2009, 36 (04) : 1359 - 1369
  • [9] K-edge imaging in x-ray computed tomography using multi-bin photon counting detectors
    Roessl, E.
    Proksa, R.
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (15) : 4679 - 4696
  • [10] Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method
    Saito, Masatoshi
    [J]. MEDICAL PHYSICS, 2009, 36 (08) : 3631 - 3642