ASSESSMENT OF IONIZING RADIATION DOSES DELIVERED TO CARDIOLOGISTS DURING INTERVENTIONAL PROCEDURES

被引:0
作者
Gedvilas, Marius [1 ]
Griciene, Birute
Medvedevas, Nikolajus [1 ]
机构
[1] Kaunas Univ Technol, Kaunas, Lithuania
来源
MEDICAL PHYSICS IN THE BALTIC STATES | 2011年
关键词
interventional; cardiology; coronary angiography; percutaneous coronary intervention; skin dose equivalent; thermoluminescence dosimeter; personal dose equivalent;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Interventional radiology provides a great number of vascular and extravascular information and therefore are commonly used in medical practice. The complexity of interventional procedures causes relative high doses to interventional cardiologists due to near vicinity of radiation source during procedures. In this paper results of measurements by thermoluminescence dosimeters of skin doses at different body height levels and doses to eye lenses accessible by interventional cardiologists are presented and discussed.
引用
收藏
页码:124 / 126
页数:3
相关论文
共 8 条
  • [1] Biie B., 2011, RADIAT PROT DOSIM, P501
  • [2] Patient doses and dosimetric evaluations in interventional cardiology
    Bor, Dogan
    Olgar, Turan
    Toklu, Tuerkay
    Caglan, Ayca
    Oenal, Elif
    Padovani, Renato
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (01): : 31 - 42
  • [3] Radiation exposure to cardiologists performing interventional cardiology procedures
    Delichas, M
    Psarrakos, K
    Molyvda-Athanassopoulou, E
    Giannoglou, G
    Sioundas, A
    Hatziioannou, K
    Papanastassiou, E
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2003, 48 (03) : 268 - 273
  • [4] Assessment of effective dose and dose to the lens of the eye for the interventional cardiologist
    Lie, Oydis Ostbye
    Paulsen, Gudrun Uthaug
    Wohni, Tor
    [J]. RADIATION PROTECTION DOSIMETRY, 2008, 132 (03) : 313 - 318
  • [5] Molyvda-Athanasopoulou E., 2011, RADIAT PROT DOSIM, P1
  • [6] Paolucci M., 2011, RAD MEASURE IN PRESS, P1
  • [7] Radiation effects analysis in a group of interventional radiologists using biological and physical dosimetry methods
    Ramos, M.
    Montoro, A.
    Almonacid, M.
    Ferrer, S.
    Barquinero, J. F.
    Tortosa, R.
    Verdu, G.
    Rodriguez, P.
    Barrios, L. L.
    Villaescusa, J. I.
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2010, 75 (02) : 259 - 264
  • [8] Radiation dose to patients and staff during angiography of the lower limbs. Derivation of local dose reference levels
    Topaltzikis, T.
    Rountas, C.
    Moisidou, R.
    Fezoulidis, I.
    Kappas, C.
    Theodoru, K.
    [J]. PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2009, 25 (01): : 25 - 30