The coupled single-port model has been proposed recently for wide-area measurement-based voltage stability assessment. This concept relies in decoupling a mesh power grid into the local single-port circuit coupled with an extra impedance. However, underestimations in this approach have been observed in simulation studies. In this paper, a modified coupled single-port model is proposed. Based on real-time PMU measurements of individual load bus, the reactive power response used in the extended Ward-type equivalent will be explored to compensate the reactive power mismatch in the existing model. In addition, a mitigation factor is introduced to modify the Thevenin equivalent parameter of the existing model. Due to the simplicity of the proposed model, several voltage stability indicators can be applied with slight modifications. Simulations on various IEEE test systems are presented to validate the accuracy of the proposed method.
引用
收藏
页码:756 / 764
页数:9
相关论文
共 32 条
[1]   THE CONTINUATION POWER FLOW - A TOOL FOR STEADY-STATE VOLTAGE STABILITY ANALYSIS [J].
AJJARAPU, V ;
CHRISTY, C .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1992, 7 (01) :416-423
[2]   POWER-SYSTEM OBSERVABILITY WITH MINIMAL PHASOR MEASUREMENT PLACEMENT [J].
BALDWIN, TL ;
MILI, L ;
BOISEN, MB ;
ADAPA, R .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1993, 8 (02) :707-715
[3]   Calculating optimal system parameters to maximize the distance to saddle-node bifurcations [J].
Canizares, CA .
IEEE TRANSACTIONS ON CIRCUITS AND SYSTEMS I-FUNDAMENTAL THEORY AND APPLICATIONS, 1998, 45 (03) :225-237
[4]   POINT OF COLLAPSE METHODS APPLIED TO AC DC POWER-SYSTEMS [J].
CANIZARES, CA ;
ALVARADO, FL ;
DEMARCO, CL ;
DOBSON, I ;
LONG, WF ;
PAL, MK ;
SEMLYEN, A .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1992, 7 (02) :673-683
[5]   CPFLOW - A PRACTICAL TOOL FOR TRACING POWER-SYSTEM STEADY-STATE STATIONARY BEHAVIOR DUE TO LOAD AND GENERATION VARIATIONS [J].
CHIANG, HD ;
FLUECK, AJ ;
SHAH, KS ;
BALU, N .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1995, 10 (02) :623-630
[6]   Reactive power response of wind generators under an incremental network-loss allocation approach [J].
De Oliveira-De Jesus, P. M. ;
Castronuovo, Edgardo D. ;
de Leao, M. T. Ponce .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2008, 23 (02) :612-621
[7]   COMPUTING A CLOSEST BIFURCATION INSTABILITY IN MULTIDIMENSIONAL PARAMETER SPACE [J].
DOBSON, I .
JOURNAL OF NONLINEAR SCIENCE, 1993, 3 (03) :307-327
[8]  
Glavic M., 2011, Power and Energy Society General Meeting, 2011 IEEE, P1
[9]  
Glavic M, 2011, P IEEE POW EN SOC GE, P24
[10]   NONLINEAR DYNAMIC LOAD MODELS WITH RECOVERY FOR VOLTAGE STABILITY STUDIES [J].
HILL, DJ ;
FISCHL, R ;
PAL, MK ;
XU, WS ;
MANSOUR, Y ;
NWANKPA, CO ;
XU, L .
IEEE TRANSACTIONS ON POWER SYSTEMS, 1993, 8 (01) :166-176