Decreasing Lab Turnaround Time Improves Emergency Department Throughput and Decreases Emergency Medical Services Diversion: A Simulation Model

被引:87
作者
Storrow, Alan B. [1 ]
Zhou, Chuan [2 ]
Gaddis, Gary [4 ]
Han, Jin H. [1 ]
Miller, Karen [1 ]
Klubert, David [5 ]
Laidig, Andy [5 ]
Aronsky, Dominik [1 ,3 ]
机构
[1] Vanderbilt Univ, Dept Emergency Med, Nashville, TN 37203 USA
[2] Vanderbilt Univ, Dept Biostat, Nashville, TN USA
[3] Vanderbilt Univ, Dept Biomed Informat, Nashville, TN USA
[4] St Lukes Hosp, Ctr Res Innovat, Kansas City, MO USA
[5] Apogee Informat Corp, Huntsville, AL USA
关键词
simulation; point-of-care testing;
D O I
10.1111/j.1553-2712.2008.00181.x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The effect of decreasing lab turnaround times on emergency department (ED) efficiency can be estimated through system-level simulation models and help identify important outcome measures to study prospectively. Furthermore, such models may suggest the advantage of bedside or point-of-care testing and how they might affect efficiency measures. The authors used a sophisticated simulation model in place at an adult urban ED with an annual census of 55,000 patient visits. The effect of decreasing turnaround times on emergency medical services (EMS) diversion, ED patient throughput, and total ED length of stay (LOS) was determined. Data were generated by using system dynamics analytic modeling and simulation approach on 90 separate days from December 2, 2007, through February 29, 2008. The model was a continuous simulation of ED flow, driven by real-time actual patient data, and had intrinsic error checking to assume reasonable goodness-of-fit. A return of complete laboratory results incrementally at 120, 100, 80, 60, 40, 20, and 10 minutes was compared. Diversion calculation assumed EMS closure when more than 10 patients were in the waiting room and 100% ED bed occupancy had been reached for longer than 30 minutes, as per local practice. LOS was generated from data insertion into the patient flow stream and calculation of time to specific predefined gates. The average accuracy of four separate measurement channels (waiting room volume, ED census, inpatient admit stream, and ED discharge stream), all across 24 hours, was measured by comparing the area under the simulated curve against the area under the measured curve. Each channel's accuracy was summed and averaged for an overall accuracy rating. As lab turnaround time decreased from 120 to 10 minutes, the total number of diversion days (maximum 57 at 120 minutes, minimum 29 at 10 minutes), average diversion hours per day (10.8 hours vs. 6.0 hours), percentage of days with diversion (63% vs. 32%), and average ED LOS (2.77 hours vs. 2.17 hours) incrementally decreased, while average daily throughput (104 patients vs. 120 patients) increased. All runs were at least 85% accurate. This simulation model suggests compelling improvement in ED efficiency with decreasing lab turnaround time. Outcomes such as time on EMS diversion, ED LOS, and ED throughput represent important but understudied areas that should be evaluated prospectively. EDs should consider processes that will improve turnaround time, such as point-of-care testing, to obtain these goals.
引用
收藏
页码:1130 / 1135
页数:6
相关论文
共 47 条
[1]   Point-of-care testing of cardiac markers: results from an experience in an Emergency Department [J].
Altinier, S ;
Zaninotto, M ;
Mion, M ;
Carraro, P ;
Rocco, S ;
Tosato, F ;
Plebani, M .
CLINICA CHIMICA ACTA, 2001, 311 (01) :67-72
[2]   Decreased patient charges following implementation of point-of-care cardiac troponin monitoring in acute coronary syndrome patients in a community hospital cardiology unit [J].
Apple, Fred S. ;
Chung, Adrine Y. ;
Kogut, Mary Ellen ;
Bubany, Susan ;
Murakami, MaryAnn M. .
CLINICA CHIMICA ACTA, 2006, 370 (1-2) :191-195
[3]  
Arendts Glenn, 2006, Emerg Med Australas, V18, P7, DOI 10.1111/j.1742-6723.2006.00798.x
[4]   Supporting patient care in the emergency department with a computerized whiteboard system [J].
Aronsky, Dominik ;
Ones, Ian ;
Lanaghan, Kevin ;
Slonvis, Corey M. .
JOURNAL OF THE AMERICAN MEDICAL INFORMATICS ASSOCIATION, 2008, 15 (02) :184-194
[5]   A conceptual model of emergency department crowding [J].
Asplin, BR ;
Magid, DJ ;
Rhodes, KV ;
Solberg, LI ;
Lurie, N ;
Camargo, CA .
ANNALS OF EMERGENCY MEDICINE, 2003, 42 (02) :173-180
[6]   Cardiac markers of acute coronary syndromes: is there a case for point-of-care testing? [J].
Azzazy, HME ;
Christenson, RH .
CLINICAL BIOCHEMISTRY, 2002, 35 (01) :13-27
[7]   Current role of platelet glycoprotein IIb/IIIa inhibitors in acute coronary syndromes [J].
Bhatt, DL ;
Topol, EJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 284 (12) :1549-1558
[8]  
BLICK KE, 2005, POINT CARE, V4, P11
[9]   Predictors of emergency department patient satisfaction: Stability over 17 months [J].
Boudreaux, ED ;
d'Autremont, S ;
Wood, K ;
Jones, GN .
ACADEMIC EMERGENCY MEDICINE, 2004, 11 (01) :51-58
[10]   Emergency department patient satisfaction: Examining the role of acuity [J].
Boudreaux, ED ;
Friedman, J ;
Chansky, ME ;
Baumann, BM .
ACADEMIC EMERGENCY MEDICINE, 2004, 11 (02) :162-168