Decreasing Lab Turnaround Time Improves Emergency Department Throughput and Decreases Emergency Medical Services Diversion: A Simulation Model

被引:85
|
作者
Storrow, Alan B. [1 ]
Zhou, Chuan [2 ]
Gaddis, Gary [4 ]
Han, Jin H. [1 ]
Miller, Karen [1 ]
Klubert, David [5 ]
Laidig, Andy [5 ]
Aronsky, Dominik [1 ,3 ]
机构
[1] Vanderbilt Univ, Dept Emergency Med, Nashville, TN 37203 USA
[2] Vanderbilt Univ, Dept Biostat, Nashville, TN USA
[3] Vanderbilt Univ, Dept Biomed Informat, Nashville, TN USA
[4] St Lukes Hosp, Ctr Res Innovat, Kansas City, MO USA
[5] Apogee Informat Corp, Huntsville, AL USA
关键词
simulation; point-of-care testing;
D O I
10.1111/j.1553-2712.2008.00181.x
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The effect of decreasing lab turnaround times on emergency department (ED) efficiency can be estimated through system-level simulation models and help identify important outcome measures to study prospectively. Furthermore, such models may suggest the advantage of bedside or point-of-care testing and how they might affect efficiency measures. The authors used a sophisticated simulation model in place at an adult urban ED with an annual census of 55,000 patient visits. The effect of decreasing turnaround times on emergency medical services (EMS) diversion, ED patient throughput, and total ED length of stay (LOS) was determined. Data were generated by using system dynamics analytic modeling and simulation approach on 90 separate days from December 2, 2007, through February 29, 2008. The model was a continuous simulation of ED flow, driven by real-time actual patient data, and had intrinsic error checking to assume reasonable goodness-of-fit. A return of complete laboratory results incrementally at 120, 100, 80, 60, 40, 20, and 10 minutes was compared. Diversion calculation assumed EMS closure when more than 10 patients were in the waiting room and 100% ED bed occupancy had been reached for longer than 30 minutes, as per local practice. LOS was generated from data insertion into the patient flow stream and calculation of time to specific predefined gates. The average accuracy of four separate measurement channels (waiting room volume, ED census, inpatient admit stream, and ED discharge stream), all across 24 hours, was measured by comparing the area under the simulated curve against the area under the measured curve. Each channel's accuracy was summed and averaged for an overall accuracy rating. As lab turnaround time decreased from 120 to 10 minutes, the total number of diversion days (maximum 57 at 120 minutes, minimum 29 at 10 minutes), average diversion hours per day (10.8 hours vs. 6.0 hours), percentage of days with diversion (63% vs. 32%), and average ED LOS (2.77 hours vs. 2.17 hours) incrementally decreased, while average daily throughput (104 patients vs. 120 patients) increased. All runs were at least 85% accurate. This simulation model suggests compelling improvement in ED efficiency with decreasing lab turnaround time. Outcomes such as time on EMS diversion, ED LOS, and ED throughput represent important but understudied areas that should be evaluated prospectively. EDs should consider processes that will improve turnaround time, such as point-of-care testing, to obtain these goals.
引用
收藏
页码:1130 / 1135
页数:6
相关论文
共 37 条
  • [1] The Effect of an Ambulance Diversion Ban on Emergency Department Length of Stay and Ambulance Turnaround Time
    Burke, Laura G.
    Joyce, Nina
    Baker, William E.
    Biddinger, Paul D.
    Dyer, K. Sophia
    Friedman, Franklin D.
    Imperato, Jason
    King, Alice
    Maciejko, Thomas M.
    Pearlmutter, Mark D.
    Sayah, Assaad
    Zane, Richard D.
    Epstein, Stephen K.
    ANNALS OF EMERGENCY MEDICINE, 2013, 61 (03) : 303 - 311
  • [2] A time-motion study of the emergency medical services turnaround interval
    Cone, DC
    Davidson, SJ
    Nguyen, Q
    ANNALS OF EMERGENCY MEDICINE, 1998, 31 (02) : 241 - 246
  • [3] Medical Laboratory/Emergency Trauma Education Decreases Turnaround Time for ED Patients
    Merrick, Terri W.
    AMERICAN JOURNAL OF CLINICAL PATHOLOGY, 2012, 138 : A248 - A248
  • [4] Decreasing troponin turnaround time in the emergency department using the central laboratory: A process improvement study
    Boelstler, Arlene M.
    Rowland, Ralph
    Theoret, Jennifer
    Takla, Robert B.
    Szpunar, Susan
    Patel, Shraddha P.
    Lowry, Andrew M.
    Pena, Margarita E.
    CLINICAL BIOCHEMISTRY, 2015, 48 (4-5) : 308 - 312
  • [5] Effect of an emergency department (ED) managed acute care unit on ED overcrowding and emergency medical services diversion
    Kelen, GD
    Scheulen, JJ
    Hill, PM
    ACADEMIC EMERGENCY MEDICINE, 2001, 8 (11) : 1095 - 1100
  • [6] The role of automation in reducing test turnaround time outliers and decreasing patient length of stay in the emergency department
    Holland, LL
    Smith, LL
    Blick, KE
    CLINICAL CHEMISTRY, 2005, 51 : A217 - A217
  • [7] Practice Policy and Quality Initiatives Decreasing Variability in Turnaround Time for Radiographic Studies from the Emergency Department
    Towbin, Alexander J.
    Iyer, Srikant B.
    Brown, James
    Varadarajan, Kartik
    Perry, Laurie A.
    Larson, David B.
    RADIOGRAPHICS, 2013, 33 (02) : 361 - 371
  • [8] A SIMULATION MODEL FOR EMERGENCY MEDICAL SERVICES CALL CENTERS
    van Buuren, Martin
    Kommer, Geert Jan
    van der Mei, Rob
    Bhulai, Sandjai
    2015 WINTER SIMULATION CONFERENCE (WSC), 2015, : 844 - 855
  • [9] CAN EMERGENCY MEDICAL SERVICES USE TURNAROUND TIME AS A PROXY FOR MEASURING AMBULANCE OFFLOAD TIME?
    Carter, Alix J. E.
    Overton, Jerry
    Terashima, Mikiko
    Cone, David C.
    JOURNAL OF EMERGENCY MEDICINE, 2014, 47 (01): : 30 - 35
  • [10] Managing emergency department overcrowding via ambulance diversion: A discrete event simulation model
    Lin, Chih-Hao
    Kao, Chung-Yao
    Huang, Chong-Ye
    JOURNAL OF THE FORMOSAN MEDICAL ASSOCIATION, 2015, 114 (01) : 64 - 71