Double Filtration During Carotid Artery Stenting Using a Novel Post-Dilation Balloon With Integrated Embolic Protection

被引:11
|
作者
Langhoff, Ralf [1 ]
Schofer, Joachim [2 ]
Scheinert, Dierk [3 ]
Schmidt, Andrej [3 ]
Sedgewick, Gerald [4 ]
Saylors, Elizabeth [5 ]
Sachar, Ravish [6 ]
Sievert, Horst [7 ,8 ]
Zeller, Thomas [9 ]
机构
[1] Sankt Gertrauden Krankenhaus GmbH, Dept Angiol, Berlin, Germany
[2] Med Care Ctr Prof Mathey, Dept Cardiol, Hamburg, Germany
[3] Univ Hosp Leipzig, Clin Angiol, Leipzig, Germany
[4] Imaging & Anal LLC, St Paul, MN USA
[5] Contego Med LLC, Raleigh, NC USA
[6] UNC REX Healthcare, Heart & Vasc Serv, Raleigh, NC USA
[7] CardioVasc Ctr Frankfurt, Frankfurt, Germany
[8] Anglia Ruskin Univ, Chelmsford, Essex, England
[9] Univ Herzzentrum Freiburg Bad Krozingen, Dept Angiol, Bad Krozingen, Germany
关键词
carotid artery stenting; cerebral embolic protection; double filtration; periprocedural stroke; SURGICAL-RISK PATIENTS; FILTER PROTECTION; DISTAL PROTECTION; ENDARTERECTOMY; TRIAL; METAANALYSIS; ANGIOPLASTY; OCCLUSION; REGISTRY; MICROEMBOLIZATION;
D O I
10.1016/j.jcin.2018.11.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study evaluated the safety and performance of the Paladin System, a novel angioplasty balloon with an integrated embolic protection filter designed to increase embolic protection during post-dilation. BACKGROUND The risk of major adverse events during carotid artery stenting (CAS) is equivalent to carotid endarterectomy. However, the risk of minor stroke remains higher with CAS. Much of this risk occurs during post-stent dilation. METHODS A total of 106 patients were enrolled in 5 centers in Germany. The study's primary endpoint was all-cause death, myocardial infarction, and stroke at 30 days post-procedure. Pre- and post-procedural diffusion-weighted magnetic resonance imaging evaluated new ischemic lesions in 30 subjects. Filter histomorphometric analysis was performed in 23 patients. Retrospective analyses compared outcome rates to historical controls. RESULTS Device and procedural success rates were 100%. The combined major adverse event rate (death, myocardial infarction, and stroke) at discharge and at 30 days was 0% and 1.0%, respectively. The single adverse event was a stroke, which occurred at day 12 and was believed unrelated to the device or procedure. New ischemic lesions were found in 11 (36.7%) patients in the diffusion-weighted magnetic resonance imaging subset. New ipsilateral lesions were seen in 9 (30.0%) patients. Mean lesion volume per patient was 0.010 cm(3). Debris was present in all filters, and approximately 90% of captured particles were <100 mm. CONCLUSIONS Use of the Paladin System for post-stent dilation during CAS appears safe, and it may effectively decrease the number of embolic particles reaching the brain, which may help reduce the risk of procedure-related stroke. (A Multi-Center Study to Evaluate Acute Safety and Clinical Performance of Paladin (R) Carotid Post-Dilation Balloon System With Integrated Embolic Protection; NCT02501148) (J Am Coll Cardiol Intv 2019;12:395-403) (c) 2019 by the American College of Cardiology Foundation.
引用
收藏
页码:395 / 403
页数:9
相关论文
共 45 条
  • [31] Clinical Analysis Comparing Efficacy between a Distal Filter Protection Device and Proximal Balloon Occlusion Device during Carotid Artery Stenting
    Lee, Jong Hyeok
    Sohn, Hee Eon
    Chung, Seung Young
    Park, Moon Sun
    Kim, Seong Min
    Lee, Do Sung
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2015, 58 (04) : 316 - 320
  • [32] Carotid artery stenting with double cerebral embolic protection in asymptomatic patients - a diffusion-weighted MRI controlled study
    Vuruskan, Ertan
    Saracoglu, Erhan
    Ergun, Ugur
    Poyraz, Fatih
    Duzen, Irfan Veysel
    VASA-EUROPEAN JOURNAL OF VASCULAR MEDICINE, 2017, 46 (01) : 29 - 35
  • [33] Very Low Rate of New Brain Lesions After Vulnerable Carotid Artery Stenting Cases Using Only FilterWire EZ as Distal Embolic Protection
    Ishida, Atsushi
    Asakuno, Keizoh
    Shiramizu, Hideki
    Yoshimoto, Haruko
    Nakase, Ko
    Kato, Masataka
    Matsuo, Seigo
    WORLD NEUROSURGERY, 2020, 141 : E145 - E150
  • [34] Tandem balloon protection during emergency carotid artery stenting of a stenotic ICA lesion with intraluminal thrombus
    Imai, Keisuke
    Makino, Masahiro
    Niwa, Furnitoshi
    Takegarni, Tetsuro
    Koike, Hironori
    Azuma, Yurniko
    Oshima, Fumiko
    Oda, Kenichiro
    Kakita, Kiyohito
    JOURNAL OF ENDOVASCULAR THERAPY, 2007, 14 (02) : 214 - 218
  • [35] Technical Complications Associated with Embolic Protection Device During Carotid Artery Stenting: Incidence, Risk Factors, Clinical Implications, and Rescue Maneuvers
    Kim, Bo Kyu
    Kim, Byungjun
    You, Sung-Hye
    Ryoo, Inseon
    Jung, Hye Na
    DIAGNOSTICS, 2024, 14 (23)
  • [36] Transfemoral Stenting of Stenoses at the Common Carotid Artery Origin Using an Anchoring Technique With a Balloon Protection Device
    Tsuji, Kiyoshi
    Fukawa, Norihito
    Nakagawa, Nobuhiro
    Watanabe, Akira
    Murakami, Saori
    Nagatsuka, Kazuhiro
    Nakano, Naoki
    Kataoka, Kazuo
    Kato, Amami
    NEUROSURGERY, 2016, 79 (04) : 598 - 603
  • [37] Carotid artery stenting with proximal embolic protection via the transbrachial approach: sheathless navigation of a 9-F balloon-guiding catheter
    Koge, Junpei
    Iwata, Tomonori
    Hashimoto, Tetsuya
    Mizuta, Shigehisa
    Nakamura, Yukihiko
    Tanaka, Eri
    Kawajiri, Masakazu
    Matsumoto, Shun-ichi
    Yamada, Takeshi
    NEURORADIOLOGY, 2018, 60 (10) : 1097 - 1101
  • [38] Initial experience of using the filter protection device during carotid artery stenting in Japan
    Takayama, Katsutoshi
    Nakagawa, Hiroyuki
    Iwasaki, Satoru
    Taoka, Toshiaki
    Miyasaka, Toshiteru
    Myouchin, Kaoru
    Wada, Takeshi
    Sakamoto, Masahiko
    Fukusumi, Akio
    Nakagawa, Ichiro
    Kurokawa, Shinichiro
    Kichikawa, Kimihiko
    RADIATION MEDICINE, 2008, 26 (06): : 348 - 354
  • [39] Carotid artery stenting with proximal embolic protection via the transbrachial approach: sheathless navigation of a 9-F balloon-guiding catheter
    Junpei Koge
    Tomonori Iwata
    Tetsuya Hashimoto
    Shigehisa Mizuta
    Yukihiko Nakamura
    Eri Tanaka
    Masakazu Kawajiri
    Shun-ichi Matsumoto
    Takeshi Yamada
    Neuroradiology, 2018, 60 : 1097 - 1101
  • [40] Initial experience of using the filter protection device during carotid artery stenting in Japan
    Katsutoshi Takayama
    Hiroyuki Nakagawa
    Satoru Iwasaki
    Toshiaki Taoka
    Toshiteru Miyasaka
    Kaoru Myouchin
    Takeshi Wada
    Masahiko Sakamoto
    Akio Fukusumi
    Ichiro Nakagawa
    Shinichiro Kurokawa
    Kimihiko Kichikawa
    Radiation Medicine, 2008, 26 : 348 - 354