Double Filtration During Carotid Artery Stenting Using a Novel Post-Dilation Balloon With Integrated Embolic Protection

被引:11
|
作者
Langhoff, Ralf [1 ]
Schofer, Joachim [2 ]
Scheinert, Dierk [3 ]
Schmidt, Andrej [3 ]
Sedgewick, Gerald [4 ]
Saylors, Elizabeth [5 ]
Sachar, Ravish [6 ]
Sievert, Horst [7 ,8 ]
Zeller, Thomas [9 ]
机构
[1] Sankt Gertrauden Krankenhaus GmbH, Dept Angiol, Berlin, Germany
[2] Med Care Ctr Prof Mathey, Dept Cardiol, Hamburg, Germany
[3] Univ Hosp Leipzig, Clin Angiol, Leipzig, Germany
[4] Imaging & Anal LLC, St Paul, MN USA
[5] Contego Med LLC, Raleigh, NC USA
[6] UNC REX Healthcare, Heart & Vasc Serv, Raleigh, NC USA
[7] CardioVasc Ctr Frankfurt, Frankfurt, Germany
[8] Anglia Ruskin Univ, Chelmsford, Essex, England
[9] Univ Herzzentrum Freiburg Bad Krozingen, Dept Angiol, Bad Krozingen, Germany
关键词
carotid artery stenting; cerebral embolic protection; double filtration; periprocedural stroke; SURGICAL-RISK PATIENTS; FILTER PROTECTION; DISTAL PROTECTION; ENDARTERECTOMY; TRIAL; METAANALYSIS; ANGIOPLASTY; OCCLUSION; REGISTRY; MICROEMBOLIZATION;
D O I
10.1016/j.jcin.2018.11.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study evaluated the safety and performance of the Paladin System, a novel angioplasty balloon with an integrated embolic protection filter designed to increase embolic protection during post-dilation. BACKGROUND The risk of major adverse events during carotid artery stenting (CAS) is equivalent to carotid endarterectomy. However, the risk of minor stroke remains higher with CAS. Much of this risk occurs during post-stent dilation. METHODS A total of 106 patients were enrolled in 5 centers in Germany. The study's primary endpoint was all-cause death, myocardial infarction, and stroke at 30 days post-procedure. Pre- and post-procedural diffusion-weighted magnetic resonance imaging evaluated new ischemic lesions in 30 subjects. Filter histomorphometric analysis was performed in 23 patients. Retrospective analyses compared outcome rates to historical controls. RESULTS Device and procedural success rates were 100%. The combined major adverse event rate (death, myocardial infarction, and stroke) at discharge and at 30 days was 0% and 1.0%, respectively. The single adverse event was a stroke, which occurred at day 12 and was believed unrelated to the device or procedure. New ischemic lesions were found in 11 (36.7%) patients in the diffusion-weighted magnetic resonance imaging subset. New ipsilateral lesions were seen in 9 (30.0%) patients. Mean lesion volume per patient was 0.010 cm(3). Debris was present in all filters, and approximately 90% of captured particles were <100 mm. CONCLUSIONS Use of the Paladin System for post-stent dilation during CAS appears safe, and it may effectively decrease the number of embolic particles reaching the brain, which may help reduce the risk of procedure-related stroke. (A Multi-Center Study to Evaluate Acute Safety and Clinical Performance of Paladin (R) Carotid Post-Dilation Balloon System With Integrated Embolic Protection; NCT02501148) (J Am Coll Cardiol Intv 2019;12:395-403) (c) 2019 by the American College of Cardiology Foundation.
引用
收藏
页码:395 / 403
页数:9
相关论文
共 45 条
  • [21] Retrieval of Entrapped Embolic Protection Device during Carotid Artery Stenting: A Case Report
    Fan, Gaoyang
    Ma, Wenyuan
    Su, Chunhai
    Feng, Lei
    Guo, Wenwen
    ANNALI ITALIANI DI CHIRURGIA, 2025, 96 (01) : 7 - 13
  • [22] Simulation study of distal balloon protection systems during carotid artery stenting
    Kuroiwa, T
    Sakai, N
    Sakaguchi, M
    Adachi, H
    Imamura, H
    Sakai, C
    Morizane, A
    Ishihara, H
    Yano, T
    Nakao, S
    Kikuchi, H
    INTERVENTIONAL NEURORADIOLOGY, 2004, 10 : 79 - 84
  • [23] Usefulness of dual protection combined with blood aspiration for distal embolic protection during carotid artery stenting
    Shigeyuki Sakamoto
    Yoshihiro Kiura
    Takahito Okazaki
    Katsuhiro Shinagawa
    Nobuhiko Ichinose
    Masaaki Shibukawa
    Yoji Orita
    Koji Shimonaga
    Yosuke Kajihara
    Kaoru Kurisu
    Acta Neurochirurgica, 2015, 157 : 371 - 377
  • [24] Distal embolic protection use during transfemoral carotid artery stenting is associated with improved in-hospital outcomes
    Wang, Sophie X.
    Marcaccio, Christina L.
    Patel, Priya B.
    Giles, Kristina A.
    Soden, Peter A.
    Schermerhorn, Marc L.
    Liang, Patric
    JOURNAL OF VASCULAR SURGERY, 2023, 77 (06)
  • [25] Entrapment of an embolic protection device within stent during carotid artery stenting: a case report
    Kim, Hyun Jin
    Kim, Sanghyeon
    Kang, Myongjin
    EGYPTIAN JOURNAL OF NEUROLOGY PSYCHIATRY AND NEUROSURGERY, 2023, 59 (01)
  • [26] Entrapment of an embolic protection device within stent during carotid artery stenting: a case report
    Hyun Jin Kim
    Sanghyeon Kim
    Myongjin Kang
    The Egyptian Journal of Neurology, Psychiatry and Neurosurgery, 59
  • [27] Hemodynamic instability during carotid artery stenting: the relative contribution of stent deployment versus balloon dilation
    Bussiere, Miguel
    Lownie, Stephen P.
    Lee, Donald
    Gulka, Irene
    Leung, Andrew
    Pelz, David M.
    JOURNAL OF NEUROSURGERY, 2009, 110 (05) : 905 - 912
  • [28] Carotid Artery Stenting Using the Walrus Balloon Guide Catheter With Flow Reversal for Proximal Embolic Protection: Technical Description and Single-Center Case Series
    Cappuzzo, Justin M.
    Monteiro, Andre
    Waqas, Muhammad
    Baig, Ammad A.
    Popoola, Daniel O.
    Almayman, Faisal
    Khawar, Wasiq I.
    Farkash, Zoe G.
    Davies, Jason M.
    Siddiqui, Adnan H.
    Levy, Elad I.
    Snyder, Kenneth V.
    OPERATIVE NEUROSURGERY, 2023, 24 (01) : 11 - 16
  • [29] Embolic protection devices during carotid artery stenting: Is there a difference between proximal occlusion and distal filter?
    Gargiulo, Giuseppe
    Stabile, Eugenio
    Sannino, Anna
    Perrino, Cinzia
    Trimarco, Bruno
    Esposito, Giovanni
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2015, 187 : 592 - 593
  • [30] Carotid Artery Stenting in High Surgical Risk Patients Using the FiberNet® Embolic Protection System: The EPIC Trial Results
    Myla, Subbarao
    Bacharach, J. Michael
    Ansel, Gary M.
    Dippel, Eric J.
    McCormick, Daniel J.
    Popma, Jeffrey J.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2010, 75 (06) : 817 - 822