Double Filtration During Carotid Artery Stenting Using a Novel Post-Dilation Balloon With Integrated Embolic Protection

被引:11
|
作者
Langhoff, Ralf [1 ]
Schofer, Joachim [2 ]
Scheinert, Dierk [3 ]
Schmidt, Andrej [3 ]
Sedgewick, Gerald [4 ]
Saylors, Elizabeth [5 ]
Sachar, Ravish [6 ]
Sievert, Horst [7 ,8 ]
Zeller, Thomas [9 ]
机构
[1] Sankt Gertrauden Krankenhaus GmbH, Dept Angiol, Berlin, Germany
[2] Med Care Ctr Prof Mathey, Dept Cardiol, Hamburg, Germany
[3] Univ Hosp Leipzig, Clin Angiol, Leipzig, Germany
[4] Imaging & Anal LLC, St Paul, MN USA
[5] Contego Med LLC, Raleigh, NC USA
[6] UNC REX Healthcare, Heart & Vasc Serv, Raleigh, NC USA
[7] CardioVasc Ctr Frankfurt, Frankfurt, Germany
[8] Anglia Ruskin Univ, Chelmsford, Essex, England
[9] Univ Herzzentrum Freiburg Bad Krozingen, Dept Angiol, Bad Krozingen, Germany
关键词
carotid artery stenting; cerebral embolic protection; double filtration; periprocedural stroke; SURGICAL-RISK PATIENTS; FILTER PROTECTION; DISTAL PROTECTION; ENDARTERECTOMY; TRIAL; METAANALYSIS; ANGIOPLASTY; OCCLUSION; REGISTRY; MICROEMBOLIZATION;
D O I
10.1016/j.jcin.2018.11.039
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study evaluated the safety and performance of the Paladin System, a novel angioplasty balloon with an integrated embolic protection filter designed to increase embolic protection during post-dilation. BACKGROUND The risk of major adverse events during carotid artery stenting (CAS) is equivalent to carotid endarterectomy. However, the risk of minor stroke remains higher with CAS. Much of this risk occurs during post-stent dilation. METHODS A total of 106 patients were enrolled in 5 centers in Germany. The study's primary endpoint was all-cause death, myocardial infarction, and stroke at 30 days post-procedure. Pre- and post-procedural diffusion-weighted magnetic resonance imaging evaluated new ischemic lesions in 30 subjects. Filter histomorphometric analysis was performed in 23 patients. Retrospective analyses compared outcome rates to historical controls. RESULTS Device and procedural success rates were 100%. The combined major adverse event rate (death, myocardial infarction, and stroke) at discharge and at 30 days was 0% and 1.0%, respectively. The single adverse event was a stroke, which occurred at day 12 and was believed unrelated to the device or procedure. New ischemic lesions were found in 11 (36.7%) patients in the diffusion-weighted magnetic resonance imaging subset. New ipsilateral lesions were seen in 9 (30.0%) patients. Mean lesion volume per patient was 0.010 cm(3). Debris was present in all filters, and approximately 90% of captured particles were <100 mm. CONCLUSIONS Use of the Paladin System for post-stent dilation during CAS appears safe, and it may effectively decrease the number of embolic particles reaching the brain, which may help reduce the risk of procedure-related stroke. (A Multi-Center Study to Evaluate Acute Safety and Clinical Performance of Paladin (R) Carotid Post-Dilation Balloon System With Integrated Embolic Protection; NCT02501148) (J Am Coll Cardiol Intv 2019;12:395-403) (c) 2019 by the American College of Cardiology Foundation.
引用
收藏
页码:395 / 403
页数:9
相关论文
共 45 条
  • [1] Transradial carotid artery stenting using double layer micromesh stent and novel post-dilation balloon with integrated embolic protection
    Petkoska, Danica
    Zafirovska, Biljana
    Vasilev, Ivan
    Saylors, Elizabeth
    Sachar, Ravish
    Kedev, Sasko
    CARDIOVASCULAR REVASCULARIZATION MEDICINE, 2024, 63 : 43 - 51
  • [2] PERFORMANCE 1 study: Novel carotid stent system with integrated post-dilation balloon and embolic protection device
    Langhoff, Ralf
    Petrov, Ivo
    Kedev, Sasko
    Milosevic, Zoran
    Schmidt, Andrej
    Scheinert, Dierk
    Schofer, Joachim
    Sievert, Horst
    Sedgewick, Gerald
    Saylors, Elizabeth
    Sachar, Ravish
    Cremonesi, Alberto
    Micari, Antonio
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 100 (06) : 1090 - 1099
  • [3] Carotid Artery Stenting Without Post-Dilation
    Spacek, Miloslav
    Zimolova, Petra
    Veselka, Josef
    JOURNAL OF INTERVENTIONAL CARDIOLOGY, 2012, 25 (02) : 190 - 196
  • [4] Evaluation of proximal protection devices during carotid artery stenting as the first choice for embolic protection
    Hornung, Marius
    Bertog, Stefan C.
    Franke, Jennifer
    Id, Dani
    Grunwald, Iris
    Sievert, Horst
    EUROINTERVENTION, 2015, 10 (11) : 1362 - 1367
  • [5] Comparison of anti-embolic protection with proximal balloon occlusion and filter devices during carotid artery stenting: clinical and procedural outcomes
    Tatli, Ersan
    Buturak, Ali
    Grunduz, Yasemin
    Dogan, Emir
    Alkan, Mustafa
    Sayin, Murat
    Yilmaztepe, Mustafa
    Atakay, Selcuk
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2013, 9 (03): : 221 - 227
  • [6] Double embolic protection during carotid artery stenting with persistent hypoglossal artery
    Silva, Christine F.
    Hou, Samuel Y.
    Kuehn, Anna L.
    Whitten, Richard H.
    Wakhloo, Ajay K.
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2014, 6 (03) : e23
  • [7] Comparison of dual protection and distal filter protection as a distal embolic protection method during carotid artery stenting: a single-center carotid artery stenting experience
    Kajihara, Yosuke
    Sakamoto, Shigeyuki
    Kiura, Yoshihiro
    Mukada, Kazutoshi
    Chaki, Takahiro
    Kajihara, Shiro
    Kurisu, Kaoru
    NEUROSURGICAL REVIEW, 2015, 38 (04) : 671 - 676
  • [8] Usefulness of dual protection combined with blood aspiration for distal embolic protection during carotid artery stenting
    Sakamoto, Shigeyuki
    Kiura, Yoshihiro
    Okazaki, Takahito
    Shinagawa, Katsuhiro
    Ichinose, Nobuhiko
    Shibukawa, Masaaki
    Orita, Yoji
    Shimonaga, Koji
    Kajihara, Yosuke
    Kurisu, Kaoru
    ACTA NEUROCHIRURGICA, 2015, 157 (03) : 371 - 377
  • [9] Postoperative ischemic events in patients undergoing carotid artery stenting using algorithmic selection for embolic protection
    Kawabata, Yasuhiro
    Nakajima, Norio
    Miyake, Hidenori
    Fukuda, Shunichi
    Tsukahara, Tetsuya
    NEURORADIOLOGY JOURNAL, 2019, 32 (04) : 294 - 302
  • [10] First clinical experience with the GARDEX EPD: a novel embolic protection device for carotid artery stenting
    Werner, Martin
    Scheinert, Dierk
    Borghesi, Raffaello
    Cremonesi, Alberto
    Rosenschein, Uri
    Scheinert, Susanne
    Braeunlich, Sven
    Bausback, Yvonne
    Ulrich, Matthias
    Schmidt, Andrej
    EUROINTERVENTION, 2013, 8 (09) : 1026 - 1032