Correspondence optimization in 2D standardized carotid wall thickness map by description length minimization: A tool for increasing reproducibility of 3D ultrasound-based measurements

被引:6
作者
Chen, Yimin [1 ]
Chiu, Bernard [1 ]
机构
[1] City Univ Hong Kong, Dept Elect Engn, Hong Kong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
point correspondence; three-dimensional ultrasound; carotid artery; vessel-wall-plus-plaque thickness (VWT); minimum description length (MDL); INTIMA-MEDIA THICKNESS; MINIMUM DESCRIPTION LENGTH; ACTIVE APPEARANCE MODELS; 3-DIMENSIONAL ULTRASOUND; VESSEL WALL; PLAQUE VOLUME; MYOCARDIAL-INFARCTION; FLATTENING MAPS; ARTERY INTIMA; RISK-FACTORS;
D O I
10.1118/1.4966702
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The previously described 2D standardized vessel-wall-plus-plaque thickness (VWT) maps constructed from 3D ultrasound vessel wall measurements using an arc-length (AL) scaling approach adjusted the geometric variability of carotid arteries and has allowed for the comparisons of VWT distributions in longitudinal and cross-sectional studies. However, this mapping technique did not optimize point correspondence of the carotid arteries investigated. The potential misalignment may lead to errors in point-wise VWT comparisons. In this paper, we developed and validated an algorithm based on steepest description length (DL) descent to optimize the point correspondence implied by the 2D VWT maps. Methods: The previously described AL approach was applied to obtain initial 2D maps for a group of carotid arteries. The 2D maps were reparameterized based on an iterative steepest DL descent approach, which consists of the following two steps. First, landmarks established by resampling the 2D maps were aligned using the Procrustes algorithm. Then, the gradient of the DL with respect to horizontal and vertical reparameterizations of each landmark on the 2D maps was computed, and the 2D maps were subsequently deformed in the direction of the steepest descent of DL. These two steps were repeated until convergence. The quality of the correspondence was evaluated in a phantom study and an in vivo study involving ten carotid arteries enrolled in a 3D ultrasound interscan variability study. The correspondence quality was evaluated in terms of the compactness and generalization ability of the statistical shape model built based on the established point correspondence in both studies. In the in vivo study, the effect of the proposed algorithm on interscan variability of VWT measurements was evaluated by comparing the percentage of landmarks with statistically significant VWT-change before and after point correspondence optimization. Results: The statistical shape model constructed with optimized correspondence was more compact and had a better generalization ability than that constructed using the AL approach in both the phantom and in vivo studies. A statistical test on the group-average VWT-Change at each point of the 2D carotid template showed that the group-average VWT-change was significantly different from 0 in 18% of landmarks when the AL approach was used, and this percentage was reduced to 11% after correspondence optimization. Conclusions: The optimized correspondence resulted in a more compact and generalizable statistical shape model, and the algorithm was shown to reduce interscan variability of point-wise VWT measurements obtained using the previously described arc-length scaling parameterization approach. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:6474 / 6490
页数:17
相关论文
共 54 条
  • [1] 3D ultrasound measurement of change in carotid plaque volume - A tool for rapid evaluation of new therapies
    Ainsworth, CD
    Blake, CC
    Tamayo, A
    Beletsky, V
    Fenster, A
    Spence, JD
    [J]. STROKE, 2005, 36 (09) : 1904 - 1909
  • [2] Differences between carotid wall morphological phenotypes measured by ultrasound in one, two and three dimensions
    Al-Shali, K
    House, AA
    Hanley, AJG
    Khan, HMR
    Harris, SB
    Mamakeesick, M
    Zinman, B
    Fenster, A
    Spence, JD
    Hegele, RA
    [J]. ATHEROSCLEROSIS, 2005, 178 (02) : 319 - 325
  • [3] Carotid artery intima-media thickness measured by ultrasonography in normal clinical practice correlates well with atherosclerosis risk factors
    Baldassarre, D
    Amato, M
    Bondioli, A
    Sirtori, CR
    Tremoli, E
    [J]. STROKE, 2000, 31 (10) : 2426 - 2430
  • [5] Nonlinear virtual colon unfolding
    Bartroli, AV
    Wegenkittl, R
    König, A
    Gröller, E
    [J]. VISUALIZATION 2001, PROCEEDINGS, 2001, : 411 - 418
  • [6] Bhatia KK, 2004, 2004 2ND IEEE INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING: MACRO TO NANO, VOLS 1 AND 2, P908
  • [7] Intima media thickness as a surrogate marker for generalised atherosclerosis
    Bots, ML
    Grobbee, DE
    [J]. CARDIOVASCULAR DRUGS AND THERAPY, 2002, 16 (04) : 341 - 351
  • [8] Common carotid intima-media thickness and risk of stroke and myocardial infarction - The Rotterdam Study
    Bots, ML
    Hoes, AW
    Koudstaal, PJ
    Hofman, A
    Grobbee, DE
    [J]. CIRCULATION, 1997, 96 (05) : 1432 - 1437
  • [9] A framework for the co-registration of hemodynamic forces and atherosclerotic plaque components
    Canton, Gador
    Chiu, Bernard
    Chen, Huijun
    Chen, Yimin
    Hatsukami, Thomas S.
    Kerwin, William S.
    Yuan, Chun
    [J]. PHYSIOLOGICAL MEASUREMENT, 2013, 34 (09) : 977 - 990
  • [10] Modeling hemodynamic forces in carotid artery based on local geometric features
    Chen, Yimin
    Canton, Gador
    Kerwin, William S.
    Chiu, Bernard
    [J]. MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2016, 54 (09) : 1437 - 1452