Automated liquid-liquid extraction based on 96-well plate format in conjunction with ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) for the quantitation of methoxsalen in human plasma

被引:12
|
作者
Yadav, Manish [1 ,2 ]
Contractor, Pritesh [2 ]
Upadhyay, Vivek [2 ]
Gupta, Ajay [2 ]
Guttikar, Swati [2 ]
Singhal, Puran [2 ]
Goswami, Sailendra [2 ]
Shrivastav, Pranav S. [1 ]
机构
[1] Gujarat Univ, Sch Sci, Dept Chem, Ahmadabad 380009, Gujarat, India
[2] Veeda Clin Res, Bioanalyt Res Dept, Ahmadabad 3800015, Gujarat, India
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2008年 / 872卷 / 1-2期
关键词
methoxsalen; 96-well plate liquid-liquid extraction; UPLC-MS/MS; high throughput; human plasma;
D O I
10.1016/j.jchromb.2008.06.058
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A sensitive, specific and high throughput bioanalytical method using automated sample processing via 96-well plate liquid-liquid extraction and ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS) has been developed for the determination of methoxsalen in human plasma. Plasma samples with ketoconazole as internal standard (IS) were prepared by employing 0.2 mL human plasma in ethyl acetate:dichloromethane (80:20, v/v). The chromatographic separation was achieved on a Waters Acquity UPLC BEH C18 column using isocratic mobile phase, consisting of 10 mM ammonium formate and acetonitrile (60:40, v/v), at a flow rate of 0.5 mL/min. The linear dynamic range was established over the concentration range 1.1-213.1 ng/mL for methoxsalen. The method was rugged and rapid with a total run time of 1.5 min. It was successfully applied to a pivotal bioequivalence study in 12 healthy human subjects after oral administration of 10 mg extended release methoxsalen formulation under fasting condition. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:167 / 171
页数:5
相关论文
共 50 条
  • [1] Liquid-liquid extraction using 96-well plate format in conjunction with liquid chromatography/tandem mass spectrometry for quantitative determination of methylphenidate (Ritalin®) in human plasma
    Ramos, L
    Bakhtiar, R
    Tse, FLS
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2000, 14 (09) : 740 - 745
  • [2] Determination of acrylamide in brewed coffee by dispersive liquid-liquid microextraction (DLLME) and ultra-performance liquid chromatography tandem mass spectrometry (UPLC-MS/MS)
    Galuch, Marilia Bellanda
    Santos Magon, Thiago Ferreira
    Silveira, Roberta
    Nicacio, Antonio Eduardo
    Pizzo, Jessica Santos
    Bonafe, Elton Guntendorfer
    Maldaner, Liane
    Santos, Oscar Oliveira
    Visentainer, Jesui Vergilio
    FOOD CHEMISTRY, 2019, 282 : 120 - 126
  • [3] Acylglycine Analysis by Ultra-Performance Liquid Chromatography-Tandem Mass Spectrometry (UPLC-MS/MS)
    Hobert, Judith A.
    Guymon, Rebecca
    Yuzyuk, Tatiana
    Pasquali, Marzia
    CURRENT PROTOCOLS, 2023, 3 (04):
  • [4] Enantiomeric separation and quantification of fluoxetine (Prozac®) in human plasma by liquid chromatography/tandem mass spectrometry using liquid-liquid extraction in 96-well plate format
    Shen, ZZ
    Wang, S
    Bakhtiar, R
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2002, 16 (05) : 332 - 338
  • [5] Quantification of acylcarnitines, and free carnitine by ultra-performance liquid chromatography/tandem mass spectrometry (UPLC-MS/MS)
    Christensen, M.
    Soeltoft, M.
    Lund, A. M.
    Christensen, E.
    JOURNAL OF INHERITED METABOLIC DISEASE, 2007, 30 : 46 - 46
  • [6] Quantitative analysis of simvastatin and its β-hydroxy acid in human plasma using automated liquid-liquid extraction based on 96-well plate format and liquid chromatography-tandem mass spectrometry
    Zhang, NY
    Yang, A
    Rogers, JD
    Zhao, JJ
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2004, 34 (01) : 175 - 187
  • [7] Liquid/liquid extraction using 96-well plate format in conjunction with hydrophilic interaction liquid chromatography-tandem mass spectrometry method for the analysis of fluconazole in human plasma
    Eerkes, A
    Shou, WZ
    Weng, ND
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 31 (05) : 917 - 928
  • [8] Comparison of plasma sample purification by manual liquid-liquid extraction, automated 96-well liquid-liquid extraction and automated 96-well solid-phase extraction for analysis by highperformance liquid chromatography with tandem mass spectrometry
    Jemal, M
    Teitz, D
    Ouyang, Z
    Khan, S
    JOURNAL OF CHROMATOGRAPHY B, 1999, 732 (02): : 501 - 508
  • [9] Determination of fluoroquinolones in aquaculture products by ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS)
    Pearce, J. N.
    Burns, B. G.
    van de Riet, J. M.
    Casey, M. D.
    Potter, R. A.
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2009, 26 (01): : 39 - 46
  • [10] Ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) for the sensitive determination of folates in rice
    De Brouwer, Veerle
    Storozhenko, Sergei
    Stove, Christophe P.
    Van Daele, Jeroen
    Van Der Straeten, Dominique
    Lambert, Willy E.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (3-4): : 509 - 513