Numerical simulation of heat transfer to separation air flow in an annular pipe

被引:32
作者
Oon, C. S. [1 ]
Togun, Hussein [1 ]
Kazi, S. N. [1 ]
Badarudin, A. [1 ]
Zubir, M. N. M. [1 ]
Sadeghinezhad, E. [1 ]
机构
[1] Univ Malaya, Dept Mech Engn, Kuala Lumpur 50603, Malaysia
关键词
Backward facing steps; Annular pipe flow; Heat exchanger; Numerical simulation; NATURAL-CONVECTION; FORCED-CONVECTION; NANOFLUID; ENCLOSURE; STEP;
D O I
10.1016/j.icheatmasstransfer.2012.06.019
中图分类号
O414.1 [热力学];
学科分类号
摘要
Separation and reattachment of air flow through a sudden expansion in an annular passage are considered in this study. Backward facing steps play a vital role in the design of many heat related applications where heat transfer is concerned. In the present work, numerical simulation is performed using computer fluid dynamics package (Fluent) to study the effect of step flow in an annular passage. The results are compared with the preliminary experimental findings. In the study, the flowing fluid was considered heated uniformly from the beginning of the expansion. Constant heat flux approach was also considered for the heat transfer investigation. Annular pipe flow system having a step ratio of D/d = 1.8 was considered where d and D are representing the diameter of the pipe before and after expansion. Numerical simulation review shows that the reattachment point extends further with the increase of velocity for different occasions. Finally, the local Nusselt number (Nu) in separation flow increases with the increase of Reynolds number (Re). (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1176 / 1180
页数:5
相关论文
共 19 条
[1]   A review of research on laminar mixed convection flow over backward- and forward-facing steps [J].
Abu-Mulaweh, HI .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2003, 42 (09) :897-909
[2]   Laminar forced convection flow over a backward facing step using nanofluids [J].
Al-aswadi, A. A. ;
Mohammed, H. A. ;
Shuaib, N. H. ;
Campo, Antonio .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2010, 37 (08) :950-957
[3]  
Ashurst W.T., 1980, S COMP VISC INV INT
[4]  
Calzada P.D.L, 2011, NUMERICAL HEAT TRA A, V60, P666
[5]  
Chang P.K., 1976, CONTROL FLOW SEPARAT
[6]  
Charwat A.E., 1961, J AEROSP SCI, V28, P512
[7]   HEAT TRANSFER IN SEPARATED REATTACHED AND REDEVELOPMENT REGIONS BEHIND A DOUBLE STEP AT ENTRANCE TO A FLAT DUCT [J].
FILETTI, EG ;
KAYS, WM .
JOURNAL OF HEAT TRANSFER, 1967, 89 (02) :163-&
[8]   Natural Convection Heat Transfer in an Inclined Enclosure Filled with a Water-Cuo Nanofluid [J].
Ghasemi, B. ;
Aminossadati, S. M. .
NUMERICAL HEAT TRANSFER PART A-APPLICATIONS, 2009, 55 (08) :807-823
[9]   Experimental study of condensation heat transfer of R-134a flow in corrugated tubes with different inclinations [J].
Khoeini, D. ;
Akhavan-Behabadi, M. A. ;
Saboonchi, A. .
INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2012, 39 (01) :138-143
[10]  
Kreith F., 2001, Principles of Heat Transfer, V6th