Effects of rotational speed on the hydrodynamic properties of pharmaceutical antibodies measured by analytical ultracentrifugation sedimentation velocity

被引:5
|
作者
Krayukhina, Elena [1 ]
Uchiyama, Susumu [1 ]
Fukui, Kiichi [1 ]
机构
[1] Osaka Univ, Grad Sch Engn, Suita, Osaka 5650871, Japan
关键词
Antibody; Analytical ultracentrifugation; Sedimentation velocity; Frictional ratio; SIZE-EXCLUSION CHROMATOGRAPHY; FIELD-FLOW FRACTIONATION; MOLECULAR-WEIGHT; PROTEIN AGGREGATION; HUMAN-IGG; QUANTITATION; DISTRIBUTIONS; FORMULATION; STRATEGIES; PARTICLES;
D O I
10.1016/j.ejps.2012.06.005
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Analytical ultracentrifugation sedimentation velocity (AUC-SV) has recently become one of the most important tools for the measurement of hydrodynamic properties of proteins. Although a number of studies using AUC-SV as applied to pharmaceutical antibodies have been conducted, the effect of rotational speed on molecular properties has not been systematically examined. The present study aimed to elucidate the influence of rotational speed on the hydrodynamic parameters of pharmaceutical antibodies. A monoclonal and a polyclonal antibody were studied by using AUC-SV at 5 different rotor speeds, and the acquired data were analyzed either by using the computer programs SEDFIT or UltraScan. The frictional ratio of the studied antibodies decreased at high rotor speeds, resulting in underestimation of molecular weight. The frictional ratio value of the monoclonal antibody measured at the low rotor speed was consistent with that of human immunoglobulin Cl computed from its three-dimensional structure. The best agreement between the measured molecular weight and the value calculated from the antibody sequence was achieved at the lower rotor speed. Similar to the results obtained using antibodies, AUC-SV analysis of human serum albumin revealed that the frictional ratio and apparent molecular weight behave in a speed-dependent manner. We deduced that the findings were mainly attributable to the hydrostatic pressure in the analytical ultracentrifuge. The current study implies that rotor speed should be carefully considered in antibody studies using AUC-SV. (c) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:367 / 374
页数:8
相关论文
共 36 条
  • [21] Quantitation of adeno-associated virus in a dual-vector system using sedimentation velocity analytical ultracentrifugation
    Yarawsky, Alexander E.
    Ciatto, Carlo
    Slade, Peter
    Figueroa, Natalya I.
    Burgner, John W.
    Delion, Michael T.
    Paul, Lake N.
    JOURNAL OF PHARMACEUTICAL SCIENCES, 2025, 114 (02) : 900 - 910
  • [22] A new adaptive grid-size algorithm for the simulation of sedimentation velocity profiles in analytical ultracentrifugation
    Brown, Patrick H.
    Schuck, Peter
    COMPUTER PHYSICS COMMUNICATIONS, 2008, 178 (02) : 105 - 120
  • [23] Determining the Stoichiometry of a Protein-Polymer Conjugate Using Multisignal Sedimentation Velocity Analytical Ultracentrifugation
    Clardy, Susan M.
    Lee, David H.
    Schuck, Peter
    BIOCONJUGATE CHEMISTRY, 2021, 32 (05) : 942 - 949
  • [24] An optical alignment system improves precision of soluble aggregate quantitation by sedimentation velocity analytical ultracentrifugation
    Doyle, Brandon L.
    Budyak, Ivan L.
    Rauk, Adam P.
    Weiss, William F.
    ANALYTICAL BIOCHEMISTRY, 2017, 531 : 16 - 19
  • [25] Analytical Ultracentrifugation Reveals Poly Acidic Amino Acids Sequence Alters Hydrodynamic Properties of SnRK2.6
    Chu Wen-Dan
    Zhou Cui-Yan
    Lu Ya-Fei
    Xu Yang
    Li Wen-Qi
    PROGRESS IN BIOCHEMISTRY AND BIOPHYSICS, 2016, 43 (03) : 256 - 264
  • [26] A simple cell-alignment protocol for sedimentation velocity analytical ultracentrifugation to complement mechanical and optical alignment procedures
    Guy Channell
    Vlad Dinu
    Gary G. Adams
    Stephen E. Harding
    European Biophysics Journal, 2018, 47 : 809 - 813
  • [27] A simple cell-alignment protocol for sedimentation velocity analytical ultracentrifugation to complement mechanical and optical alignment procedures
    Channell, Guy
    Dinu, Vlad
    Adams, Gary G.
    Harding, Stephen E.
    EUROPEAN BIOPHYSICS JOURNAL WITH BIOPHYSICS LETTERS, 2018, 47 (07): : 809 - 813
  • [28] Mutational analysis of the energetics of the GrpE•DnaK binding interface:: Equilibrium association constants by sedimentation velocity analytical ultracentrifugation
    Gelinas, AD
    Toth, J
    Bethoney, KA
    Stafford, WF
    Harrison, CJ
    JOURNAL OF MOLECULAR BIOLOGY, 2004, 339 (02) : 447 - 458
  • [29] Analytical Ultracentrifugation Sedimentation Velocity for the Characterization of Detergent-Solubilized Membrane Proteins Ca++-ATPase and ExbB
    Andrés G. Salvay
    Monica Santamaria
    Marc le Maire
    Christine Ebel
    Journal of Biological Physics, 2007, 33 : 399 - 419
  • [30] Analytical Ultracentrifugation Sedimentation Velocity for the Characterization of Detergent-Solubilized Membrane Proteins Ca++-ATPase and ExbB
    Salvay, Andres G.
    Santamaria, Monica
    le Maire, Marc
    Ebel, Christine
    JOURNAL OF BIOLOGICAL PHYSICS, 2007, 33 (5-6) : 399 - 419