Application of parylene-coated quartz crystal microbalance for on-line real-time detection of microbial populations

被引:14
作者
Han, Hsieh-Cheng [1 ,2 ]
Chang, Ying-Rong [1 ,2 ]
Hsu, Wen-Lin [3 ]
Chen, Chien-Yuan [1 ,2 ,3 ]
机构
[1] Natl Taiwan Univ, Inst Microbiol & Biochem, Taipei 10764, Taiwan
[2] Natl Taiwan Univ, Dept Biochem Sci & Technol, Taipei 10764, Taiwan
[3] Buddhist Tzu Chi Gen Hosp, Dept Radiat Oncol, Taichung Branch, Taichung, Taiwan
关键词
Quartz crystal microbalance; Parylene; pQCM sensor; E; coli; Mass loading; Fermentation process; PSEUDOMONAS-AERUGINOSA; ESCHERICHIA-COLI; ELECTRICAL-CONDUCTIVITY; CLINICAL MASTITIS; IMMUNOSENSORS; BIOSENSOR; SPECIMENS; TAQMAN; SENSOR;
D O I
10.1016/j.bios.2008.07.033
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel technique of applying a quartz crystal microbalance (QCM) sensor to the on-line real-time detection of microbial populations is described. The pQCM sensor was fabricated by depositing di-para-xylene (parylene) over the entire surface of a QCM sensor through a chemical vapor deposition (CVD) process. An electrically insulated film of parylene on the QCM sensor enabled the operation of the sensor in the liquid environment, and the resonance frequency of the pQCM sensor set in the medium of a cultivation flask shifted in response to the microbial population. The effects of pH, conductivity, and viscosity of the medium on the frequency shift of the pQCM sensor were investigated. Ignorable responses (less than 1% at 10(3) cells) were obtained during an incubation cycle. The detection limit of the pQCM sensor was identified as 10(2) cells ml(-1) with a frequency shift of around 2 x 10(3) Hz. The cell numbers of Escherichia coli cultivated in both the YEM medium and whole milk were detected. A satisfactory correlation (r(2) = 0.95) was obtained between the cell number and the response of the pQCM sensor. Experimental results suggest that the pQCM described here is applicable to the continuous long-term detection of microbial populations during a fermentation process. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1543 / 1549
页数:7
相关论文
共 50 条
[41]   Real-time detection of Escherichia coli O157:H7 sequences using a circulating-flow system of quartz crystal microbalance [J].
Wu, Vivian C. H. ;
Chen, Sz-Hau ;
Lin, Chih-Sheng .
BIOSENSORS & BIOELECTRONICS, 2007, 22 (12) :2967-2975
[42]   Real-time analysis of dual-display phage immobilization and autoantibody screening using quartz crystal microbalance with dissipation monitoring [J].
Rajaram, Kaushik ;
Losada-Perez, Patricia ;
Vermeeren, Veronique ;
Hosseinkhani, Baharak ;
Wagner, Patrick ;
Somers, Veerle ;
Michiels, Luc .
INTERNATIONAL JOURNAL OF NANOMEDICINE, 2015, 10 :5237-5247
[43]   Towards real-time observation of conditioning film and early biofilm formation under laminar flow conditions using a quartz crystal microbalance [J].
Chen, Ming-Yang ;
Chen, Ming-Jen ;
Lee, Pei-Fang ;
Cheng, Li-Hsin ;
Huang, Li-Jen ;
Lai, Chin-Hsing ;
Huang, Kuei-Hsiang .
BIOCHEMICAL ENGINEERING JOURNAL, 2010, 53 (01) :121-130
[44]   Quartz crystal microbalance for real-time monitoring chlorosilane gas transport in slim vertical cold wall chemical vapor deposition reactor [J].
Takahashi, Toshinori ;
Otani, Mana ;
Muroi, Mitsuko ;
Irikura, Kenta ;
Matsuo, Miya ;
Yamada, Ayami ;
Habuka, Hitoshi ;
Ishida, Yuuki ;
Ikeda, Shin-Ichi ;
Hara, Shiro .
MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2020, 106
[45]   A real time detection of the ovarian tumor associated antigen 1 (OVTA 1) in human serum by quartz crystal microbalance immobilized with anti-OVTA 1 polyclonal chicken IgY antibodies [J].
Sadhasivam, S. ;
Chen, Jung-Chih ;
Savitha, S. ;
Lin, Feng-Huei ;
Yang, Yi-Yuan ;
Lee, Chi-Hsin .
MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (07) :2073-2078
[46]   Determining real-time mass deposition with a quartz crystal microbalance in an electrostatic, parallel-flow, air-liquid interface exposure system [J].
Kaur, Kamaljeet ;
Overacker, Dana ;
Ghandehari, Hamidreza ;
Reilly, Christopher ;
Paine, Robert ;
Kelly, Kerry E. .
JOURNAL OF AEROSOL SCIENCE, 2021, 151
[47]   Photoinduced Agn0 cluster deposition -: Photoreduction of Ag+ ions on a TiO2-coated quartz crystal microbalance monitored in real time [J].
Hidaka, Hisao ;
Honjo, Haruo ;
Horikoshi, Satoshi ;
Serpone, Nick .
SENSORS AND ACTUATORS B-CHEMICAL, 2007, 123 (02) :822-828
[48]   In-situ, real-time investigation of the formation of oxygen-containing rare-earth hydrides by combining a quartz crystal microbalance and ion beam analysis [J].
Pitthan, E. ;
Cupak, C. ;
Fellinger, M. ;
Moro, M. V. ;
Kioumourtzoglou, S. ;
Moldarev, D. ;
Wolff, M. ;
Aumayr, F. ;
Primetzhofer, D. .
MATERIALIA, 2023, 27
[49]   Electrochemical processes of nucleation and growth of calcium phosphate on titanium supported by real-time quartz crystal microbalance measurements and X-ray photoelectron spectroscopy analysis [J].
Eliaz, Noam ;
Kopelovitch, William ;
Burstein, Larisa ;
Kobayashi, Equo ;
Hanawa, Takao .
JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2009, 89A (01) :270-280
[50]   The evaluation of loop-mediated isothermal amplification-quartz crystal microbalance (LAMP-QCM) biosensor as a real-time measurement of HPV16 DNA [J].
Jearanaikoon, Patcharee ;
Prakrankamanant, Preeda ;
Leelayuwat, Chanvit ;
Wanram, Surasak ;
Limpaiboon, Temduang ;
Promptmas, Chamras .
JOURNAL OF VIROLOGICAL METHODS, 2016, 229 :8-11