Application of parylene-coated quartz crystal microbalance for on-line real-time detection of microbial populations

被引:14
|
作者
Han, Hsieh-Cheng [1 ,2 ]
Chang, Ying-Rong [1 ,2 ]
Hsu, Wen-Lin [3 ]
Chen, Chien-Yuan [1 ,2 ,3 ]
机构
[1] Natl Taiwan Univ, Inst Microbiol & Biochem, Taipei 10764, Taiwan
[2] Natl Taiwan Univ, Dept Biochem Sci & Technol, Taipei 10764, Taiwan
[3] Buddhist Tzu Chi Gen Hosp, Dept Radiat Oncol, Taichung Branch, Taichung, Taiwan
关键词
Quartz crystal microbalance; Parylene; pQCM sensor; E; coli; Mass loading; Fermentation process; PSEUDOMONAS-AERUGINOSA; ESCHERICHIA-COLI; ELECTRICAL-CONDUCTIVITY; CLINICAL MASTITIS; IMMUNOSENSORS; BIOSENSOR; SPECIMENS; TAQMAN; SENSOR;
D O I
10.1016/j.bios.2008.07.033
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A novel technique of applying a quartz crystal microbalance (QCM) sensor to the on-line real-time detection of microbial populations is described. The pQCM sensor was fabricated by depositing di-para-xylene (parylene) over the entire surface of a QCM sensor through a chemical vapor deposition (CVD) process. An electrically insulated film of parylene on the QCM sensor enabled the operation of the sensor in the liquid environment, and the resonance frequency of the pQCM sensor set in the medium of a cultivation flask shifted in response to the microbial population. The effects of pH, conductivity, and viscosity of the medium on the frequency shift of the pQCM sensor were investigated. Ignorable responses (less than 1% at 10(3) cells) were obtained during an incubation cycle. The detection limit of the pQCM sensor was identified as 10(2) cells ml(-1) with a frequency shift of around 2 x 10(3) Hz. The cell numbers of Escherichia coli cultivated in both the YEM medium and whole milk were detected. A satisfactory correlation (r(2) = 0.95) was obtained between the cell number and the response of the pQCM sensor. Experimental results suggest that the pQCM described here is applicable to the continuous long-term detection of microbial populations during a fermentation process. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:1543 / 1549
页数:7
相关论文
共 50 条
  • [1] On-line monitoring of parylene film deposition with quartz crystal microbalance (QCM)
    Lee, Ga-Yeon
    Ko, Hyuk
    Jung, Ha-Wook
    Ye, Suk-Jin
    Kim, Moo-Hwan
    Pyun, Jae-Chul
    EUROSENSORS XXV, 2011, 25
  • [2] Immunoglobulin-Immobilized Quartz Crystal Microbalance for Staphylococcus Aureus Real-Time Detection
    Xu, Zhangliang
    Luo, Yang
    IEEE SENSORS JOURNAL, 2022, 22 (12) : 11594 - 11601
  • [3] A molecularly imprinted nanofilm-based quartz crystal microbalance sensor for the real-time detection of pirimicarb
    Cakir, Oguz
    JOURNAL OF MOLECULAR RECOGNITION, 2019, 32 (09)
  • [4] Real-time monitoring of a stepwise transcription reaction on a quartz-crystal microbalance
    Takahashi, Shuntaro
    Hisanaga, Kazuya
    Yoshida, Aya
    Okahata, Yoshio
    ANALYTICAL BIOCHEMISTRY, 2012, 421 (02) : 732 - 741
  • [5] Highly sensitive, direct and real-time detection of silver nanowires by using a quartz crystal microbalance
    Jang, Kuewhan
    Park, Chanho
    You, Juneseok
    Choi, Jaeyeong
    Park, Hyunjun
    Park, Jinsung
    Lee, Howon
    Choi, Chang-Hwan
    Na, Sungsoo
    NANOTECHNOLOGY, 2016, 27 (47)
  • [6] Real-time molecular recognition between protein and photosensitizer of photodynamic therapy by quartz crystal microbalance sensor
    Yang, Yu
    Long, Yuanyuan
    Li, Zhiyu
    Li, Na
    Li, Kean
    Liu, Feng
    ANALYTICAL BIOCHEMISTRY, 2009, 392 (01) : 22 - 27
  • [7] Using Quartz Crystal Microbalance to Provide Real-Time Process Monitoring
    Tsuchiyama, Hirofumi
    Lakeman, Steven
    2020 INTERNATIONAL SYMPOSIUM ON SEMICONDUCTOR MANUFACTURING (ISSM), 2020,
  • [8] Real-time monitoring of enzymatic cleavage of nucleic acids using a quartz crystal microbalance
    Wang, J
    Jiang, M
    Palecek, E
    BIOELECTROCHEMISTRY AND BIOENERGETICS, 1999, 48 (02): : 477 - 480
  • [9] Real-time and sensitive detection of Salmonella Typhimurium using an automated quartz crystal microbalance (QCM) instrument with nanoparticles amplification
    Salam, Faridah
    Uludag, Yildiz
    Tothill, Ibtisam E.
    TALANTA, 2013, 115 : 761 - 767
  • [10] Novel quartz crystal microbalance based biosensor for detection of oral epithelial cell-microparticle interaction in real-time
    Elsom, Jacqueline
    Lethem, Michael I.
    Rees, Gareth D.
    Hunter, A. Christy
    BIOSENSORS & BIOELECTRONICS, 2008, 23 (08) : 1259 - 1265